Intratester Reliability and Validity of Concentric Measurements Using a New Hand-Held Dynamometer

被引:21
|
作者
Janssen, Jessie C. [1 ]
Le-Ngoc, Lan [1 ]
机构
[1] Ind Res Ltd, Christchurch, New Zealand
来源
关键词
Muscle strength dynamometer; Rehabilitation; Reliability and validity; AGREEMENT; INSTRUMENT; STRENGTH; BIODEX;
D O I
10.1016/j.apmr.2009.02.021
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To assess the reliability of a new hand-held dynamometer (HHD) to perform concentric measurements, and to determine the agreement between the HHD and the criterion standard isokinetic dynamometer. Design: Elbow flexion concentric measurements were performed on a mechanical arm using the HHD and the isokinetic dynamometer. Setting: Engineering laboratory and university strength-testing facility. Participants: Three patient profiles, differing in range of motion (ROM) and strength, were simulated by a mechanical arm. Interventions: Not applicable. Main Outcome Measures: Peak torque and ROM obtained from concentric elbow flexion profiles. Results: Intratester reliabilities, measured with the intraclass correlation coefficient (ICC1,1), of the peak torque and start and end ROM are excellent for both the HHD (.99, .98, and .99, respectively) and the isokinetic dynamometer (.99 for all 3 variables). The angle of peak torque was rated fair to good in intrareliability for both devices, at .64 (HHD) and .69 (isokinetic dynamometer). Validity, measured within the limits of agreement (LOA) between the 2 devices, was clinically acceptable for peak torque and start ROM, although not for end ROM and angle of peak torque. Conclusions: It is possible to use the new HHD to obtain dynamic measurements of joint motion. Intratester reliability of the HHD is excellent and is in clinical acceptable agreement with the isokinetic dynamometer for peak torque and start ROM. End ROM was, however, not in agreement because of a systematic error in the isokinetic dynamometer measurement for I of the 3 tested profiles. Intratester reliabilities of the angle of peak torque were fair to good for both the HHD and isokinetic dynamometer, but the LOA were not clinically acceptable. Stability of the arm and speed of measurement might be confounding factors in this study.
引用
收藏
页码:1541 / 1547
页数:7
相关论文
共 50 条
  • [1] VALIDITY AND RELIABILITY OF A HAND-HELD DYNAMOMETER WITH 2 POPULATIONS
    SURBURG, PR
    SUOMI, R
    POPPY, WK
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1992, 16 (05): : 229 - 234
  • [2] INTRATESTER RELIABILITY OF STRENGTH TESTING IN DYSTROPHIC AND NORMAL-CHILDREN USING A HAND-HELD DYNAMOMETER
    STUBERG, WA
    METCALF, WK
    [J]. PHYSICAL THERAPY, 1986, 66 (05): : 800 - 800
  • [3] Reliability and validity of measurements of cervical retraction strength obtained with a hand-held dynamometer
    Tudini, Frank
    Myers, Bradley
    Bohannon, Richard
    [J]. JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2019, 27 (04) : 222 - 228
  • [4] RELIABILITY, COMPARABILITY, AND VALIDITY OF FOOT INVERSION AND EVERSION STRENGTH MEASUREMENTS USING A HAND-HELD DYNAMOMETER
    Alfuth, Martin
    Murielle, Magali
    [J]. INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2016, 11 (01): : 72 - 84
  • [5] INTERDEVICE RELIABILITY AND VALIDITY ASSESSMENT OF THE NICHOLAS HAND-HELD DYNAMOMETER
    TRUDELLEJACKSON, E
    JACKSON, AW
    FRANKOWSKI, CM
    LONG, KM
    MESKE, NB
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1994, 20 (06): : 302 - 306
  • [6] Reliability of measurements of hip abduction strength obtained with a hand-held dynamometer
    Ieiri, Akira
    Tushima, Eiki
    Ishida, Kazuhiro
    Inoue, Masahiro
    Kanno, Taiki
    Masuda, Takeshi
    [J]. PHYSIOTHERAPY THEORY AND PRACTICE, 2015, 31 (02) : 146 - 152
  • [7] Reliability and Validity of the Hand-Held Dynamometer in Measuring Hip External Rotation Strength
    Quinlevan, Megan
    Boland, Samantha
    Dodge, Erica
    Gribble, Phillip
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 196 - 196
  • [8] VALIDITY AND RELIABILITY OF A HAND-HELD DYNAMOMETER APPLIED TO ADULTS WITH MENTAL-RETARDATION
    SURBURG, PR
    SUOMI, R
    POPPY, WK
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1992, 73 (06): : 535 - 539
  • [9] Reliability and validity of eccentric strength measurement of the shoulder abductor muscles using a hand-held dynamometer
    Karabay, Damla
    Yesilyaprak, Sevgi Sevi
    Picak, Gonca Sahiner
    [J]. PHYSICAL THERAPY IN SPORT, 2020, 43 : 52 - 57
  • [10] Reliability and Validity of Hand-Held Dynamometer and Hand-Held Sphygmomanometer for Testing Shoulder Isometric External and Internal Rotator Muscles Strength
    Bettariga, Francesco
    Lopomo, Nicola Francesco
    Civera, Fabio
    Lazzarini, Stefano Giuseppe
    Mantovani, Lisa
    Maestroni, Luca
    [J]. JOURNAL OF SCIENCE IN SPORT AND EXERCISE, 2023,