Reliability of measurements of hip abduction strength obtained with a hand-held dynamometer

被引:24
|
作者
Ieiri, Akira [1 ]
Tushima, Eiki [2 ]
Ishida, Kazuhiro [1 ]
Inoue, Masahiro [3 ]
Kanno, Taiki [3 ]
Masuda, Takeshi [3 ]
机构
[1] Eniwa Hosp, Dept Rehabil, Eniwa City, Hokkaido 0611449, Japan
[2] Hirosaki Univ, Grad Sch Hlth Sci, Hirosaki, Aomori, Japan
[3] Eniwa Hosp, Dept Orthoped Surg, Eniwa City, Hokkaido 0611449, Japan
关键词
Belt fixation; hand fixation; handheld dynamometer; hip abductor muscle strength; supine position; MUSCLE STRENGTH; ARTHROPLASTY; KNEE; VALIDITY;
D O I
10.3109/09593985.2014.960539
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
This study aimed to evaluate intrarater and interrater reliability when measuring hip abductor strength in the supine position using a hand-held dynamometer (HHD) (Study 1), and to elucidate the relationships between measured values and examiners' physical characteristics (Study 2). Three healthy examiners (1 female, 24 y.o. and 2 males 23 and 27 y.o) and 12 subjects (6 females, 24.5 +/- 2.8 years and 6 males, 27.7 +/- 3.5 years) participated in Study 1, and 20 healthy examiners (7 females, 22.3 +/- 1.3 years and 13 males, 29.4 +/- 8.2 years) and 2 subjects (1 female, 24 y.o. and 1 male 27 y.o) participated in Study 2. All healthy examiners were hospital employees. Hip abductor strength was measured by HHD with hand fixation and with belt fixation, and examiner age, sex, height, weight, BMI, and dominant hand grip strength were evaluated. The intraclass correlation coefficient (ICC) (1,1), a measure of intrarater reliability, was 0.89-0.95 with hand fixation and 0.96-0.97 with belt fixation. ICC (2,1), a measure of interrater reliability, was 0.76-0.79 and 0.90-0.93, respectively. In subjects with high muscle strength (the examiner's hand was moved), the examiner's dominant hand grip strength affected muscle strength values with hand fixation (standardized partial regression coefficient = 0.78, determination coefficient R-2 = 0.61, p<0.01). In subjects with low muscle strength (the examiner's hand was not moved), no variables had effect. When the muscle strength of the subject is weak, both methods can be used. When the muscle strength of the subject is strong, it is necessary to adjust the value obtained by the examiner's dominant hand grip strength in the hand fixation method.
引用
收藏
页码:146 / 152
页数:7
相关论文
共 50 条
  • [1] Reliability and validity of measurements of cervical retraction strength obtained with a hand-held dynamometer
    Tudini, Frank
    Myers, Bradley
    Bohannon, Richard
    [J]. JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2019, 27 (04) : 222 - 228
  • [2] Knee and hip strength measurements obtained by a hand-held dynamometer stabilized by a belt and an examiner demonstrate parallel reliability but not agreement
    Florencio, Lidiane L.
    Martins, Jaqueline
    da Silva, Marcelo R. B.
    da Silva, Janaina R.
    Bellizzi, Gustavo L.
    Bevilaqua-Grossi, Debora
    [J]. PHYSICAL THERAPY IN SPORT, 2019, 38 : 115 - 122
  • [3] RELIABILITY OF MUSCLE STRENGTH MEASURES OBTAINED WITH A HAND-HELD DYNAMOMETER IN AN ELDERLY POPULATION
    Buckinx, F.
    Croisier, J. L.
    Reginster, J. -Y.
    Dardenne, N.
    Beaudart, C.
    Slomian, J.
    Bruyere, O.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2015, 26 : S161 - S161
  • [4] Reliability of muscle strength measures obtained with a hand-held dynamometer in an elderly population
    Buckinx, Fanny
    Croisier, Jean-Louis
    Reginster, Jean-Yves
    Dardenne, Nadia
    Beaudart, Charlotte
    Slomian, Justine
    Leonard, Sylvain
    Bruyere, Olivier
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2017, 37 (03) : 332 - 340
  • [5] Reliability and Validity of the Hand-Held Dynamometer in Measuring Hip External Rotation Strength
    Quinlevan, Megan
    Boland, Samantha
    Dodge, Erica
    Gribble, Phillip
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 196 - 196
  • [6] Clinical assessment of hip strength using a hand-held dynamometer is reliable
    Thorborg, K.
    Petersen, J.
    Magnusson, S. P.
    Holmich, P.
    [J]. SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2010, 20 (03) : 493 - 501
  • [7] RELIABILITY, COMPARABILITY, AND VALIDITY OF FOOT INVERSION AND EVERSION STRENGTH MEASUREMENTS USING A HAND-HELD DYNAMOMETER
    Alfuth, Martin
    Murielle, Magali
    [J]. INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2016, 11 (01): : 72 - 84
  • [8] Reliability of the Hand-Held Dynamometer During Hip Isometric Strength Testing Both With and Without a Stabilization Strap
    Beard, Megan Q.
    Boland, Samantha A.
    Gribble, Phillip A.
    [J]. INTERNATIONAL JOURNAL OF ATHLETIC THERAPY & TRAINING, 2020, 25 (01): : 37 - 42
  • [9] Reliability of measuring hip abductor strength following total knee arthroplasty using a hand-held dynamometer
    Schache, Margaret B.
    McClelland, Jodie A.
    Webster, Kate E.
    [J]. DISABILITY AND REHABILITATION, 2016, 38 (06) : 597 - 600
  • [10] Reliability of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer
    Suzuki, Terumi
    [J]. JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (03) : 967 - 971