Reliability and validity of the Biodex system 3 pro isokinetic dynamometer velocity, torque and position measurements

被引:552
|
作者
Drouin, JM
Valovich-mcLeod, TC
Shultz, SJ
Gansneder, BM
Perrin, DH
机构
[1] Georgia So Univ, Dept Publ Hlth, Statesboro, GA 30460 USA
[2] Arizona Sch Hlth Sci, Dept Sports Hlth Care, Mesa, AZ 85206 USA
[3] Univ N Carolina, Dept Exercise & Sports Sci, Greensboro, NC 27402 USA
[4] Univ Virginia, Dept Educ Leadership & Fdn, Charlottesville, VA 22904 USA
[5] Univ N Carolina, Sch Hlth & Human Performance, Greensboro, NC 27402 USA
关键词
muscle function; muscle testing; reliability; validity;
D O I
10.1007/s00421-003-0933-0
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
This study quantitatively assessed the mechanical reliability and validity of position, torque and velocity measurements of the Biodex System 3 isokinetic dynamometer. Trial-to-trial and day-to-day reliability were assessed during three trials on two separate days. To assess instrument validity, measurement of each variable using the Biodex System 3 dynamometer was compared to a criterion measure of position, torque and velocity. Position was assessed at 5degrees increments across the available range of motion of the dynamometer. Torque measures were assessed isometrically by hanging six different calibrated weights from the lever arm. Velocity was assessed (30degrees/s to 500degrees/s) across a 70degrees arc of motion by manually accelerating the weighted lever arm. With the exception of a systematic decrease in velocity at speeds of 300degrees/s and higher, the Biodex System 3 performed with acceptable mechanical reliability and validity on all variables tested.
引用
收藏
页码:22 / 29
页数:8
相关论文
共 50 条
  • [21] Biomechanical Examination of Wrist Flexors and Extensors with Biodex System Dynamometer-Isometric, Isokinetic and Isotonic Protocol Options
    Jokiel, Marta
    Kazmierczak, Katarzyna
    Czarnecki, Piotr
    Bartkowiak-Graczyk, Aleksandra
    Madziewicz, Anna
    Breborowicz, Ewa
    Miedzyblocka, Malgorzata
    Adamski, Michal
    Kaczmarek, Krystian
    Kaczmarek, Leszek
    Romanowski, Leszek
    MEDICINA-LITHUANIA, 2024, 60 (07):
  • [22] RELIABILITY OF ISOKINETIC MEASUREMENTS OF HIP MUSCLE TORQUE IN YOUNG BOYS
    BURNETT, CN
    BETTS, EF
    KING, WM
    PHYSICAL THERAPY, 1990, 70 (04): : 244 - 249
  • [23] Test-Retest Reliability of Isokinetic Ankle, Knee and Hip Strength in Physically Active Adults Using Biodex System 4 Pro
    Tuominen, Juho
    Leppanen, Mari
    Jarske, Heidi
    Pasanen, Kati
    Vasankari, Tommi
    Parkkari, Jari
    METHODS AND PROTOCOLS, 2023, 6 (02)
  • [24] Validity of trunk extensor and flexor torque measurements using isokinetic dynamometry
    Guilhem, Gael
    Giroux, Caroline
    Couturier, Antoine
    Maffiuletti, Nicola A.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2014, 24 (06) : 986 - 993
  • [25] Comparison of values generated during isokinetic-testing of the knee extensor and flexor muscles using the cybex 6000 and biodex 3 isokinetic dynamometer
    Keilani, M. Y.
    Posch, M.
    Zorn, C.
    Knoetig, M.
    Pircher, M.
    Quittan, M.
    Fialka-Moser, V.
    Jirasek, U.
    Crevenna, R.
    PHYSIKALISCHE MEDIZIN REHABILITATIONSMEDIZIN KURORTMEDIZIN, 2007, 17 (06) : 327 - 333
  • [26] Reliability of knee extension and flexion measurements using the Con-Trex isokinetic dynamometer
    Maffiuletti, Nicola A.
    Bizzini, Mario
    Desbrosses, Kevin
    Babault, Nicolas
    Munzinger, Urs
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2007, 27 (06) : 346 - 353
  • [27] Intrarater reliability of the Humac NORM isokinetic dynamometer for strength measurements of the knee and shoulder muscles
    Habets B.
    Staal J.B.
    Tijssen M.
    Van Cingel R.
    BMC Research Notes, 11 (1)
  • [28] Validity of Isometric Muscle Strength Measurements of the Lower Limbs Using a Hand-held Dynamometer and Belt: a Comparison with an Isokinetic Dynamometer
    Katoh, Munenori
    Hiiragi, Yukinobu
    Uchida, Manabu
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2011, 23 (04) : 553 - 557
  • [29] Reliability and concurrent validity of a functional electromechanical dynamometer device for the assessment of movement velocity
    Rodriguez-Perea, Angela
    Jerez-Mayorga, Daniel
    Garcia-Ramos, Amador
    Martinez-Garcia, Dario
    Chirosa Rios, Luis J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2021, 235 (03) : 176 - 181
  • [30] ISOKINETIC PLANTAR FLEXION ENDURANCE - RELIABILITY AND VALIDITY OF OUTPUT EXCITATION MEASUREMENTS
    FUGLMEYER, AR
    GERDLE, B
    ERIKSSON, BE
    JONSSON, B
    SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 1985, 17 (02): : 47 - 52