Cone beam X-ray scatter removal via image frequency modulation and filtering

被引:17
|
作者
Bani-Hashemi, A
Blanz, E
Maltz, J
Hristov, D
Svatos, M
机构
关键词
D O I
10.1118/1.1998387
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a rapid method of patient scatter removal from cone beam (CB) projection images that requires no scatter measurement, physical modeling or strong assumptions regarding the spatial smoothness of the scatter distribution. Method and Materials: A modulator grid is placed between the imaged distribution and the detector that differentially frequency modulates primary and scattered photons. When photons travel through the grid, photons that originate directly from the CB source are modulated by a higher frequency than scattered photons that have more proximal, diffusely distributed sources. We employ non‐linear Fourier domain filtering to attenuate the contribution of scatter to the image spectrum. The theoretical validity of the method is verified using linear analysis of planar sources and its performance is evaluated using a simulator based on this analytical model. Results: Simulation experiments with an ideal modulator indicate that even unrealistically large amounts of scatter are almost entirely removed by this method. The recovered images are devoid of major artifacts and exhibit an RMS error of 10%. Conclusion: A disadvantage of the technique is that it will always produce a filtered image having at best 0.41 of the maximum detector resolution when maximum scatter rejection is desired. This is not a major issue in most medical X‐ray CB imaging applications using contemporary detector technology, especially since scatter often significantly reduces useful resolution. Conflict of Interest: Supported by Siemens Medical Solutions USA, Inc. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2093 / 2093
页数:1
相关论文
共 50 条
  • [31] Learning Scatter Artifact Correction in Cone-Beam X-Ray CT Using Incomplete Projections with Beam Hole Array
    Hattori, Haruki
    Yatagawa, Tatsuya
    Ohtake, Yutaka
    Suzuki, Hiromasa
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2024, 43 (03)
  • [32] Algorithm for x-ray beam hardening and scatter correction in low-dose cone-beam CT: Phantom studies
    Liu, Wenlei
    Rong, Junyan
    Gao, Peng
    Liao, Qimei
    Lu, HongBing
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [33] A Fast, Analytical Pencil Beam Based Method for First Order X-Ray Scatter Estimation of Kilovoltage Cone Beam X-Rays
    Liu, J.
    Bourland, J.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [34] Pencil beam coded aperture x-ray scatter imaging
    MacCabe, Kenneth
    Krishnamurthy, Kalyani
    Chawla, Amarpreet
    Marks, Daniel
    Samei, Ehsan
    Brady, David
    OPTICS EXPRESS, 2012, 20 (15): : 16310 - 16320
  • [35] A new method for x-ray scatter correction:: first assessment on a cone-beam CT experimental setup
    Rinkel, J.
    Gerfault, L.
    Esteve, F.
    Dinten, J-M
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (15): : 4633 - 4652
  • [36] Magnitude and effects of X-ray scatter of a cone-beam micro-CT for small animal imaging
    Ni, Y. C.
    Jan, M. L.
    Chen, K. W.
    Cheng, Y. D.
    Chuang, K. S.
    Fu, Y. K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 245 - 249
  • [37] X-ray scatter correction for dedicated cone beam breast CT using a forward-projection model
    Shi, Linxi
    Vedantham, Srinivasan
    Karellas, Andrew
    Zhu, Lei
    MEDICAL PHYSICS, 2017, 44 (06) : 2312 - 2320
  • [38] Simulation of x-ray images from the planning CT for online correction of scatter in cone-beam CT
    Rit, S.
    Romero, E.
    Oliva, M. Vila
    Brousmiche, S.
    Sarrut, D.
    Letang, J. M.
    Freud, N.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S115 - S115
  • [39] Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter
    Siewerdsen, JH
    Jaffray, DA
    MEDICAL PHYSICS, 2001, 28 (02) : 220 - 231
  • [40] A simple, direct method for X-ray scatter estimation and correction in digital radiography and cone-beam CT
    Siewerdsen, JH
    Daly, MJ
    Bakhtiar, B
    Moseley, DJ
    Richard, S
    Keller, H
    Jaffray, DA
    MEDICAL PHYSICS, 2006, 33 (01) : 187 - 197