Cone beam X-ray scatter removal via image frequency modulation and filtering

被引:17
|
作者
Bani-Hashemi, A
Blanz, E
Maltz, J
Hristov, D
Svatos, M
机构
关键词
D O I
10.1118/1.1998387
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a rapid method of patient scatter removal from cone beam (CB) projection images that requires no scatter measurement, physical modeling or strong assumptions regarding the spatial smoothness of the scatter distribution. Method and Materials: A modulator grid is placed between the imaged distribution and the detector that differentially frequency modulates primary and scattered photons. When photons travel through the grid, photons that originate directly from the CB source are modulated by a higher frequency than scattered photons that have more proximal, diffusely distributed sources. We employ non‐linear Fourier domain filtering to attenuate the contribution of scatter to the image spectrum. The theoretical validity of the method is verified using linear analysis of planar sources and its performance is evaluated using a simulator based on this analytical model. Results: Simulation experiments with an ideal modulator indicate that even unrealistically large amounts of scatter are almost entirely removed by this method. The recovered images are devoid of major artifacts and exhibit an RMS error of 10%. Conclusion: A disadvantage of the technique is that it will always produce a filtered image having at best 0.41 of the maximum detector resolution when maximum scatter rejection is desired. This is not a major issue in most medical X‐ray CB imaging applications using contemporary detector technology, especially since scatter often significantly reduces useful resolution. Conflict of Interest: Supported by Siemens Medical Solutions USA, Inc. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2093 / 2093
页数:1
相关论文
共 50 条
  • [41] Coherent Cone-Beam X-ray Microscopy
    Harder, R.
    Xiao, X.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 429 - 432
  • [42] Virtual scatter modulation for X-ray CT scatter correction using primary modulator
    Gao, Hewei
    Zhu, Lei
    Fahrig, Rebecca
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (06) : 869 - 885
  • [43] Spatial Frequency Spectrum of the X-Ray Scatter Distribution in CBCT
    Bootsma, G.
    Verhaegen, F.
    Jaffray, D.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [44] An X-ray frequency modulation method and its application in X-ray communication
    Su, Tong
    Tang, Liangyu
    Li, Yao
    Sheng, Lizhi
    Zhao, Baosheng
    OPTIK, 2019, 199
  • [45] Cone-beam x-ray tomography with arbitrary-orientation x-ray tube
    Sueseenak, D.
    Chanwimalueang, T.
    Narkbuekaew, W.
    Chitsakul, K.
    Pintavirooj, C.
    ICIEA 2006: 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, PROCEEDINGS, 2006, : 1631 - 1634
  • [46] Cone-beam X-ray tomography with arbitrary-orientation X-ray ribe
    Sueseenak, D.
    Chanwimalueang, T.
    Narkbuekaew, W.
    Chitsakul, K.
    Pintavirooj, C.
    2006 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, 2006, : 1300 - +
  • [47] Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging
    Chen, Dongmei
    Zhu, Shouping
    Chen, Xueli
    Chao, Tiantian
    Cao, Xu
    Zhao, Fengjun
    Huang, Liyu
    Liang, Jimin
    APPLIED PHYSICS LETTERS, 2014, 105 (19)
  • [48] Efficiency of capturing a phase image using cone-beam x-ray Talbot interferometry
    Yashiro, Wataru
    Takeda, Yoshihiro
    Momose, Atsushi
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2008, 25 (08) : 2025 - 2039
  • [49] X-Ray Image Improvement by Filtering of Scattered Radiation
    Blinov A.B.
    Blinov N.N.
    Biomedical Engineering, 2014, 47 (05) : 235 - 238
  • [50] EIGENIMAGE FILTERING FOR X-RAY IMAGE-ENHANCEMENT
    ABDALLAH, M
    WINDHAM, JP
    FARISON, JB
    OHIO JOURNAL OF SCIENCE, 1984, 84 (02) : 30 - 30