Cone beam X-ray scatter removal via image frequency modulation and filtering

被引:17
|
作者
Bani-Hashemi, A
Blanz, E
Maltz, J
Hristov, D
Svatos, M
机构
关键词
D O I
10.1118/1.1998387
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a rapid method of patient scatter removal from cone beam (CB) projection images that requires no scatter measurement, physical modeling or strong assumptions regarding the spatial smoothness of the scatter distribution. Method and Materials: A modulator grid is placed between the imaged distribution and the detector that differentially frequency modulates primary and scattered photons. When photons travel through the grid, photons that originate directly from the CB source are modulated by a higher frequency than scattered photons that have more proximal, diffusely distributed sources. We employ non‐linear Fourier domain filtering to attenuate the contribution of scatter to the image spectrum. The theoretical validity of the method is verified using linear analysis of planar sources and its performance is evaluated using a simulator based on this analytical model. Results: Simulation experiments with an ideal modulator indicate that even unrealistically large amounts of scatter are almost entirely removed by this method. The recovered images are devoid of major artifacts and exhibit an RMS error of 10%. Conclusion: A disadvantage of the technique is that it will always produce a filtered image having at best 0.41 of the maximum detector resolution when maximum scatter rejection is desired. This is not a major issue in most medical X‐ray CB imaging applications using contemporary detector technology, especially since scatter often significantly reduces useful resolution. Conflict of Interest: Supported by Siemens Medical Solutions USA, Inc. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2093 / 2093
页数:1
相关论文
共 50 条
  • [21] X-ray scatter correction for cone-beam CT using moving blocker array
    Zhu, L
    Strobel, N
    Fahrig, R
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 251 - 258
  • [22] Investigation into the influence of x-ray scatter on the imaging performance of an x-ray flat panel imager based cone beam volume CT
    Tang, XY
    Ning, R
    Yu, RF
    Conover, D
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 851 - 860
  • [24] Data consistency-driven scatter kernel optimization for x-ray cone-beam CT
    Kim, Changhwan
    Park, Miran
    Sung, Younghun
    Lee, Jaehak
    Choi, Jiyoung
    Cho, Seungryong
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (15): : 5971 - 5994
  • [25] A direct, empirical method for x-ray scatter correction in digital radiography and cone-beam CT
    Siewerdsen, J
    Bakhtiar, B
    Moseley, D
    Richard, S
    Keller, H
    Daly, M
    Jaffray, D
    MEDICAL PHYSICS, 2005, 32 (06) : 2092 - 2093
  • [26] Comparison of Scatter/Primary Measurements with GATE Simulations for X-Ray Spectra in Cone Beam CT Mammography
    Chen, Yu
    Liu, Bob
    O'Connor, Michael
    Didier, Clay S.
    Glick, Stephen J.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3909 - 3914
  • [27] Monte Carlo Simulations of the Effects of Bowtie Filtration on X-Ray Scatter in Cone-Beam CT
    Bootsma, G.
    Verhaegen, F.
    Jaffray, D.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [28] Ring artifact suppression and removal algorithm for an X-ray cone beam CT system
    Hang, Jiajuan
    Han, Jifeng
    Zhang, Yirong
    Yi, Chuqi
    Ma, Tianchi
    Long, Yiyang
    He, Junhan
    Wang, Penghui
    Qu, Guofeng
    Liu, Xingquan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2025, 1072
  • [29] Algorithm for X-ray Scatter, Beam-Hardening, and Beam Profile Correction in Diagnostic (Kilovoltage) and Treatment (Megavoltage) Cone Beam CT
    Maltz, Jonathan S.
    Gangadharan, Bijumon
    Bose, Supratik
    Hristov, Dimitre H.
    Faddegon, Bruce A.
    Paidi, Ajay
    Bani-Hashemi, Ali R.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (12) : 1791 - 1810
  • [30] Developments in and experience of kilovoltage X-ray cone beam image-guided radiotherapy
    Moore, C. J.
    Amer, A.
    Marchant, T.
    Sykes, J. R.
    Davies, J.
    Stratford, J.
    McCarthy, C.
    MacBain, C.
    Henry, A.
    Price, P.
    Williams, P. C.
    BRITISH JOURNAL OF RADIOLOGY, 2006, 79 : S66 - S78