Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter

被引:506
|
作者
Siewerdsen, JH [1 ]
Jaffray, DA [1 ]
机构
[1] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI 48073 USA
关键词
flat-panel imager; cone-beam computed tomography; x-ray scatter; scatter-to-primary ratio; artifacts; contrast; noise; contrast-to-noise ratio;
D O I
10.1118/1.1339879
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A system for cone-beam computed tomography (CBCT) based on a flat-panel imager (FPI) is used to examine the magnitude and effects of x-ray scatter in FPI-CBCT volume reconstructions. The system is being developed for application in image-guided therapies and has previously demonstrated spatial resolution and soft-tissue visibility comparable or superior to a conventional CT scanner under conditions of low x-ray scatter. For larger objects consistent with imaging of human anatomy (e.g., the pelvis) and for increased cone angle (i.e., larger volumetric reconstructions), however, the effects of x-ray scatter become significant. The magnitude of x-ray scatter with which the FPI-CBCT system must contend is quantified in terms of the scatter-to-primary energy fluence ratio (SPR) and scatter intensity profiles in the detector plane, each measured as a function of object size and cone angle. For large objects and cone angles (e.g., a pelvis imaged with a cone angle of 6 degrees), SPR in excess of 100% is observed. Associated with such levels of x-ray scatter are cup and streak artifacts as well as reduced accuracy in reconstruction values, quantified herein across a range of SPR consistent with the clinical setting. The effect of x-ray scatter on the contrast, noise, and contrast-to-noise ratio (CNR) in FPI-CBCT reconstructions was measured as a function of SPR and compared to predictions of a simple analytical model. The results quantify the degree to which elevated SPR degrades the CNR. For example, FPI-CBCT images of a breast-equivalent insert in water were degraded in CNR by nearly a factor of 2 for SPR ranging from similar to2% to 120%. The analytical model for CNR provides a quantitative understanding of the relationship between CNR, dose, and spatial resolution and allows knowledgeable selection of the acquisition and reconstruction parameters that, for a given SPR, are required to restore the CNR to values achieved under conditions of low x-ray scatter. For example, for SPR=100%, the CNR in FPI-CBCT images can be fully restored by: (1) increasing the dose by a factor of 4 (at full spatial resolution); (2) increasing dose and slice thickness by a factor of 2; or (3) increasing slice thickness by a factor of 4 (with no increase in dose). Other reconstruction parameters, such as transaxial resolution length and reconstruction filter, can be similarly adjusted to achieve CNR equal to that obtained in the scatter-free case. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:220 / 231
页数:12
相关论文
共 50 条
  • [1] Cone-beam computed tomography with a flat-panel imager: Effects of image lag
    Siewerdsen, JH
    Jaffray, DA
    [J]. MEDICAL PHYSICS, 1999, 26 (12) : 2635 - 2647
  • [2] Optimal x-ray imaging geometry for flat-panel cone-beam computed tomography
    Siewerdsen, JH
    Jaffray, DA
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 106 - 107
  • [3] Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
    Jaffray, DA
    Siewerdsen, JH
    [J]. MEDICAL PHYSICS, 2000, 27 (06) : 1311 - 1323
  • [4] Investigation of the Lag Effect in X-Ray Flat-Panel Detector for Cone-Beam Computed Tomography
    A. K. Avakyan
    I. L. Dergacheva
    A. A. Elanchik
    T. A. Krylova
    T. K. Lobzhanidze
    S. A. Polikhov
    V. P. Smirnov
    [J]. Biomedical Engineering, 2020, 54 : 179 - 183
  • [5] Investigation of the Lag Effect in X-Ray Flat-Panel Detector for Cone-Beam Computed Tomography
    Avakyan, A. K.
    Dergacheva, I. L.
    Elanchik, A. A.
    Krylova, T. A.
    Lobzhanidze, T. K.
    Polikhov, S. A.
    Smirnov, V. P.
    [J]. BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2020, 54 (03): : 179 - 183
  • [6] Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography)
    Siewerdsen, JH
    Jaffray, DA
    [J]. MEDICAL PHYSICS, 2000, 27 (08) : 1903 - 1914
  • [7] Cone-beam computed tomography on a medical linear accelerator using a flat-panel imager
    Jaffray, DA
    Siewerdsen, JH
    Groh, B
    Drake, DG
    Wong, JW
    Martinez, AA
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 558 - 560
  • [8] Planar cone-beam computed tomography with a flat-panel detector
    Kim, S. H.
    Kim, D. W.
    Youn, H.
    Kim, D.
    Kam, S.
    Jeon, H.
    Kim, H. K.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10
  • [9] Cone-beam CT with a flat-panel imager: Noise considerations for fully 3-D computed tomography
    Siewerdsen, JH
    Jaffray, DA
    [J]. MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 408 - 416
  • [10] Low-dose 2.5 MV cone-beam computed tomography with thick CsI flat-panel imager
    Tang, Grace
    Moussot, Christopher
    Morf, Daniel
    Seppi, Edward
    Amols, Howard
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 235 - 245