Model-based vs hybrid iterative reconstruction technique in ultralow-dose submillisievert CT colonography

被引:17
|
作者
Lambert, L. [1 ]
Ourednicek, P. [2 ]
Jahoda, J. [1 ]
Lambertova, A. [3 ]
Danes, J. [1 ]
机构
[1] Charles Univ Prague, Fac Med 1, Dept Radiol, Prague, Czech Republic
[2] St Annes Univ Hosp, Dept Imaging Methods, Brno, Czech Republic
[3] Charles Univ Prague, Fac Med 1, Dept Psychiat, Prague, Czech Republic
来源
BRITISH JOURNAL OF RADIOLOGY | 2015年 / 88卷 / 1048期
关键词
COLORECTAL POLYPS; IMAGE QUALITY; CANCER; FEASIBILITY; STANDARD; LESIONS;
D O I
10.1259/bjr.20140667
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare image quality of different reconstruction techniques in submillisievert ultralow-dose CT colonography (CTC) and to correlate colonic findings with subsequent optical colonoscopy. Methods: 58 patients underwent ultralow-dose CTC. The images were reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (HIR) or model-based iterative reconstruction (MBIR) techniques. In each segment, endoluminal noise (expressed as standard deviation of endoluminal density) was measured and image quality was rated on a five-point Likert scale by two independent readers. Colonic lesions were evaluated in consensus and correlated with subsequent optical colonoscopy where possible. Results: The estimated radiation dose was 0.41 +/- 0.05mSv for the supine and 0.42 +/- 0.04mSv for the prone acquisitions. In the endoluminal view, the image quality was rated better in HIR, whereas better scores were obtained in MBIR in the cross-sectional view, where the endoluminal noise was the lowest (p < 0.0001). Five (26%) polyps were not identified using both computer-aided detection and endoluminal inspection in FBP images vs only one (5%) in MBIR and none in HIR images. Conclusion: This study showed that in submillisievert ultralow-dose CTC, the image quality for the endoluminal view is better when HIR is used, whereas MBIR yields superior images for the cross-sectional view. The inferior quality of images reconstructed with FBP may result in decreased detection of colonic lesions. Advances in knowledge: Radiation dose from CTC can be safely reduced <1mSv for both positions when iterative reconstruction is used. MBIR provides better image quality in the cross-sectional view and HIR in the endoluminal view.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Model-based iterative reconstruction in ultra-low-dose pediatric chest CT: comparison with adaptive statistical iterative reconstruction
    Kim, Hae Jin
    Yoo, So-Young
    Jeon, Tae Yeon
    Kim, Ji Hye
    CLINICAL IMAGING, 2016, 40 (05) : 1018 - 1022
  • [42] The Application of a New Model-Based Iterative Reconstruction in Low-Dose Upper Abdominal CT
    Jia, Yongjun
    Zhai, Bingying
    He, Taiping
    Yu, Yong
    Yu, Nan
    Duan, Haifeng
    Yang, Chuangbo
    Zhang, Xirong
    ACADEMIC RADIOLOGY, 2019, 26 (10) : E275 - E283
  • [43] Assessment of image quality in abdominal CT: potential dose reduction with model-based iterative reconstruction
    Kataria, Bharti
    Althen, Jonas Nilsson
    Smedby, Orjan
    Persson, Anders
    Sokjer, Hannibal
    Sandborg, Michael
    EUROPEAN RADIOLOGY, 2018, 28 (06) : 2464 - 2473
  • [44] Assessment of image quality in abdominal CT: potential dose reduction with model-based iterative reconstruction
    Bharti Kataria
    Jonas Nilsson Althén
    Örjan Smedby
    Anders Persson
    Hannibal Sökjer
    Michael Sandborg
    European Radiology, 2018, 28 : 2464 - 2473
  • [45] Dose reduction in CT urography and vasculature phantom studies using model-based iterative reconstruction
    Page, Leland
    Wei, Wei
    Kundra, Vikas
    Rong, X. John
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 334 - 342
  • [46] Hybrid and Model-Based Iterative Reconstruction Influences the Volumetry of Visceral and Subcutaneous Adipose Tissue on Ultra-Low-Dose CT
    Lambert, Lukas
    Novak, Matej
    Siklova, Michaela
    Krauzova, Eva
    Stich, Vladimir
    Burgetova, Andrea
    OBESITY, 2020, 28 (11) : 2083 - 2089
  • [47] Estimation of Statistical Weights for Model-Based Iterative CT Reconstruction
    Haase, V
    Stierstorfer, K.
    Hahn, K.
    Schoendube, H.
    Maier, A.
    Noo, F.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [48] Ultralow-Dose Abdominal Computed Tomography: Comparison of 2 Iterative Reconstruction Techniques in a Prospective Clinical Study
    Khawaja, Ranish Deedar Ali
    Singh, Sarabjeet
    Blake, Michael
    Harisinghani, Mukesh
    Choy, Gary
    Karosmanoglu, Ali
    Padole, Atul
    Pourjabbar, Saravenaz
    Do, Synho
    Kalra, Mannudeep K.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (04) : 489 - 498
  • [49] Renovascular CT: comparison between adaptive statistical iterative reconstruction and model-based iterative reconstruction
    Noda, Y.
    Goshima, S.
    Koyasu, H.
    Shigeyama, S.
    Miyoshi, T.
    Kawada, H.
    Kawai, N.
    Matsuo, M.
    CLINICAL RADIOLOGY, 2017, 72 (10) : 901.e13 - 901.e19
  • [50] CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction
    Yasutaka Ichikawa
    Kakuya Kitagawa
    Naoki Nagasawa
    Shuichi Murashima
    Hajime Sakuma
    BMC Medical Imaging, 13