Model-based vs hybrid iterative reconstruction technique in ultralow-dose submillisievert CT colonography

被引:17
|
作者
Lambert, L. [1 ]
Ourednicek, P. [2 ]
Jahoda, J. [1 ]
Lambertova, A. [3 ]
Danes, J. [1 ]
机构
[1] Charles Univ Prague, Fac Med 1, Dept Radiol, Prague, Czech Republic
[2] St Annes Univ Hosp, Dept Imaging Methods, Brno, Czech Republic
[3] Charles Univ Prague, Fac Med 1, Dept Psychiat, Prague, Czech Republic
来源
BRITISH JOURNAL OF RADIOLOGY | 2015年 / 88卷 / 1048期
关键词
COLORECTAL POLYPS; IMAGE QUALITY; CANCER; FEASIBILITY; STANDARD; LESIONS;
D O I
10.1259/bjr.20140667
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare image quality of different reconstruction techniques in submillisievert ultralow-dose CT colonography (CTC) and to correlate colonic findings with subsequent optical colonoscopy. Methods: 58 patients underwent ultralow-dose CTC. The images were reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (HIR) or model-based iterative reconstruction (MBIR) techniques. In each segment, endoluminal noise (expressed as standard deviation of endoluminal density) was measured and image quality was rated on a five-point Likert scale by two independent readers. Colonic lesions were evaluated in consensus and correlated with subsequent optical colonoscopy where possible. Results: The estimated radiation dose was 0.41 +/- 0.05mSv for the supine and 0.42 +/- 0.04mSv for the prone acquisitions. In the endoluminal view, the image quality was rated better in HIR, whereas better scores were obtained in MBIR in the cross-sectional view, where the endoluminal noise was the lowest (p < 0.0001). Five (26%) polyps were not identified using both computer-aided detection and endoluminal inspection in FBP images vs only one (5%) in MBIR and none in HIR images. Conclusion: This study showed that in submillisievert ultralow-dose CTC, the image quality for the endoluminal view is better when HIR is used, whereas MBIR yields superior images for the cross-sectional view. The inferior quality of images reconstructed with FBP may result in decreased detection of colonic lesions. Advances in knowledge: Radiation dose from CTC can be safely reduced <1mSv for both positions when iterative reconstruction is used. MBIR provides better image quality in the cross-sectional view and HIR in the endoluminal view.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Submillisievert CT using model-based iterative reconstruction with lung-specific setting: An initial phantom study
    Akinori Hata
    Masahiro Yanagawa
    Osamu Honda
    Tomoko Gyobu
    Ken Ueda
    Noriyuki Tomiyama
    European Radiology, 2016, 26 : 4457 - 4464
  • [22] Submillisievert CT using model-based iterative reconstruction with lung-specific setting: An initial phantom study
    Hata, Akinori
    Yanagawa, Masahiro
    Honda, Osamu
    Gyobu, Tomoko
    Ueda, Ken
    Tomiyama, Noriyuki
    EUROPEAN RADIOLOGY, 2016, 26 (12) : 4457 - 4464
  • [23] Model-Based Iterative Reconstruction in Low-Dose CT Colonography-Feasibility Study in 65 Patients for Symptomatic Investigation
    Vardhanabhuti, Varut
    James, Julia
    Nensey, Rehaan
    Hyde, Christopher
    Roobottom, Carl
    ACADEMIC RADIOLOGY, 2015, 22 (05) : 563 - 571
  • [24] Submillisievert Radiation Dose Coronary CT Angiography: Clinical Impact of the Knowledge-Based Iterative Model Reconstruction
    Iyama, Yuji
    Nakaura, Takeshi
    Kidoh, Masafumi
    Oda, Seitaro
    Utsunomiya, Daisuke
    Sakaino, Naritsugu
    Tokuyasu, Shinichi
    Osakabe, Hirokazu
    Harada, Kazunori
    Yamashita, Yasuyuki
    ACADEMIC RADIOLOGY, 2016, 23 (11) : 1393 - 1401
  • [25] Knowledge-based iterative model reconstruction (IMR) algorithm in ultralow-dose CT for evaluation of urolithiasis: evaluation of radiation dose reduction, image quality, and diagnostic performance
    Sung Bin Park
    Yang Soo Kim
    Jong Beum Lee
    Hyun Jeong Park
    Abdominal Imaging, 2015, 40 : 3137 - 3146
  • [26] Model-Based Iterative Reconstruction in CT Enterography
    Murphy, Kevin P.
    Crush, Lee
    Twomey, Maria
    McLaughlin, Patrick D.
    Mildenberger, Iris C.
    Moore, Niamh
    Bye, Jackie
    O'Connor, Owen J.
    McSweeney, Sean E.
    Shanahan, Fergus
    Maher, Michael M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (06) : 1173 - 1181
  • [27] Evaluation of the depiction ability of the microanatomy of the temporal bone in quarter-detector CT Model-based iterative reconstruction vs hybrid iterative reconstruction
    Kurokawa, Ryo
    Maeda, Eriko
    Mori, Harushi
    Amemiya, Shiori
    Sato, Jiro
    Ino, Kenji
    Torigoe, Rumiko
    Abe, Osamu
    MEDICINE, 2019, 98 (24)
  • [28] Knowledge-based iterative model reconstruction (IMR) algorithm in ultralow-dose CT for evaluation of urolithiasis: evaluation of radiation dose reduction, image quality, and diagnostic performance
    Park, Sung Bin
    Kim, Yang Soo
    Lee, Jong Beum
    Park, Hyun Jeong
    ABDOMINAL IMAGING, 2015, 40 (08): : 3137 - 3146
  • [29] Head-to-head comparison of adaptive statistical and model-based iterative reconstruction algorithms for submillisievert coronary CT angiography
    Benz, Dominik C.
    Fuchs, Tobias A.
    Grani, Christoph
    Bruengger, Annina A. Studer
    Clerc, Olivier F.
    Mikulicic, Fran
    Messerli, Michael
    Stehli, Julia
    Possner, Mathias
    Pazhenkottil, Aju P.
    Gaemperli, Oliver
    Kaufmann, Philipp A.
    Buechel, Ronny R.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2018, 19 (02) : 193 - 198
  • [30] Reducing Radiation Dose at Chest CT: Comparison Among Model-based Type Iterative Reconstruction, Hybrid Iterative Reconstruction, and Filtered Back Projection
    de Margerie-Mellon, Constance
    de Bazelaire, Cedric
    Montlahuc, Claire
    Lambert, Jerome
    Martineau, Antoine
    Coulon, Philippe
    de Kerviler, Eric
    Beigeman, Catherine
    ACADEMIC RADIOLOGY, 2016, 23 (10) : 1246 - 1254