Assessment of image quality in abdominal CT: potential dose reduction with model-based iterative reconstruction

被引:42
|
作者
Kataria, Bharti [1 ]
Althen, Jonas Nilsson [2 ]
Smedby, Orjan [3 ]
Persson, Anders [1 ]
Sokjer, Hannibal [4 ]
Sandborg, Michael [2 ]
机构
[1] Linkoping Univ, Dept Radiol, Dept Med & Hlth Sci, Ctr Med Image Sci & Visualizat CMIV, S-58185 Linkoping, Sweden
[2] Linkoping Univ, Dept Med & Hlth Sci, Dept Med Phys, Linkoping, Sweden
[3] KTH Royal Inst, STH, Stockholm, Sweden
[4] Linkoping Univ, Dept Med & Hlth Sci, S-58183 Linkoping, Sweden
关键词
Dose; Computed tomography; Iterative reconstruction; Abdomen; FBP; FILTERED BACK-PROJECTION; COMPUTED-TOMOGRAPHY; ALGORITHM; PHANTOM; MBIR;
D O I
10.1007/s00330-017-5113-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To estimate potential dose reduction in abdominal CT by visually comparing images reconstructed with filtered back projection (FBP) and strengths of 3 and 5 of a specific MBIR. A dual-source scanner was used to obtain three data sets each for 50 recruited patients with 30, 70 and 100% tube loads (mean CTDIvol 1.9, 3.4 and 6.2 mGy). Six image criteria were assessed independently by five radiologists. Potential dose reduction was estimated with Visual Grading Regression (VGR). Comparing 30 and 70% tube load, improved image quality was observed as a significant strong effect of log tube load and reconstruction method with potential dose reduction relative to FBP of 22-47% for MBIR strength 3 (p < 0.001). For MBIR strength 5 no dose reduction was possible for image criteria 1 (liver parenchyma), but dose reduction between 34 and 74% was achieved for other criteria. Interobserver reliability showed agreement of 71-76% (kappa (w) 0.201-0.286) and intra-observer reliability of 82-96% (kappa (w) 0.525-0.783). MBIR showed improved image quality compared to FBP with positive correlation between MBIR strength and increasing potential dose reduction for all but one image criterion. aEuro cent MBIR's main advantage is its de-noising properties, which facilitates dose reduction. aEuro cent MBIR allows for potential dose reduction in relation to FBP. aEuro cent Visual Grading Regression (VGR) produces direct numerical estimates of potential dose reduction. aEuro cent MBIR strengths 3 and 5 dose reductions were 22-34 and 34-74%. aEuro cent MBIR strength 5 demonstrates inferior performance for liver parenchyma.
引用
收藏
页码:2464 / 2473
页数:10
相关论文
共 50 条
  • [1] Assessment of image quality in abdominal CT: potential dose reduction with model-based iterative reconstruction
    Bharti Kataria
    Jonas Nilsson Althén
    Örjan Smedby
    Anders Persson
    Hannibal Sökjer
    Michael Sandborg
    [J]. European Radiology, 2018, 28 : 2464 - 2473
  • [2] Evaluation of an Iterative model-based reconstruction of pediatric abdominal CT with regard to image quality and radiation dose
    Aurumskjold, Marie-Louise
    Soderberg, Marcus
    Stalhammar, Fredrik
    von Steyern, Kristina Vult
    Tingberg, Anders
    Ydstrom, Kristina
    [J]. ACTA RADIOLOGICA, 2018, 59 (06) : 740 - 747
  • [3] Improving image quality with model-based iterative reconstruction at quarter of nominal dose in upper abdominal CT
    Zhang, Xirong
    Chen, Jing
    Yu, Nan
    Ren, Zhanli
    Tian, Qian
    Tian, Xin
    He, Taiping
    Guo, Changyi
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2018, 92 (1093):
  • [4] Assessment of image quality in abdominal computed tomography: Effect of model-based iterative reconstruction, multi-planar reconstruction and slice thickness on potential dose reduction
    Kataria, Bharti
    Althen, Jonas Nilsson
    Smedby, Orjan
    Persson, Anders
    Sokjer, Hannibal
    Sandborg, Michael
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2020, 122
  • [5] Objective assessment of image quality and dose reduction in CT iterative reconstruction
    Vaishnav, J. Y.
    Jung, W. C.
    Popescu, L. M.
    Zeng, R.
    Myers, K. J.
    [J]. MEDICAL PHYSICS, 2014, 41 (07)
  • [6] IMAGE QUALITY AND POTENTIAL DOSE REDUCTION USING ADVANCED MODELED ITERATIVE RECONSTRUCTION (ADMIRE) IN ABDOMINAL CT - A REVIEW
    Kataria, B.
    Althen, J. Nilsson
    Smedby, O.
    Persson, A.
    Sokjer, H.
    Sandborg, M.
    [J]. RADIATION PROTECTION DOSIMETRY, 2021, 195 (3-4) : 177 - 187
  • [7] Assessment of a Model-Based, Iterative Reconstruction Algorithm (MBIR) Regarding Image Quality and Dose Reduction in Liver Computed Tomography
    Chang, Won
    Lee, Jeong Min
    Lee, Kyunghee
    Yoon, Jeong Hee
    Yu, Mi Hye
    Han, Joon Koo
    Choi, Byung Ihn
    [J]. INVESTIGATIVE RADIOLOGY, 2013, 48 (08) : 598 - 606
  • [8] Model-based Iterative Reconstruction: Effect on Patient Radiation Dose and Image Quality in Pediatric Body CT
    Smith, Ethan A.
    Dillman, Jonathan R.
    Goodsitt, Mitchell M.
    Christodoulou, Emmanuel G.
    Keshavarzi, Nahid
    Strouse, Peter J.
    [J]. RADIOLOGY, 2014, 270 (02) : 526 - 534
  • [9] Ultra-low-dose lung screening CT with model-based iterative reconstruction: an assessment of image quality and lesion conspicuity
    Ju, Yun Hye
    Lee, Geewon
    Lee, Jiwon
    Hong, Seung Baek
    Suh, Young Ju
    Jeong, Yeon Joo
    [J]. ACTA RADIOLOGICA, 2018, 59 (05) : 553 - 559
  • [10] Model-based Iterative CT Image Reconstruction on GPUs
    Sabne, Amit
    Wang, Xiao
    Kisner, Sherman
    Bouman, Charles
    Raghunathan, Anand
    Midkiff, Samuel
    [J]. ACM SIGPLAN NOTICES, 2017, 52 (08) : 207 - 220