Assessment of image quality in abdominal CT: potential dose reduction with model-based iterative reconstruction

被引:42
|
作者
Kataria, Bharti [1 ]
Althen, Jonas Nilsson [2 ]
Smedby, Orjan [3 ]
Persson, Anders [1 ]
Sokjer, Hannibal [4 ]
Sandborg, Michael [2 ]
机构
[1] Linkoping Univ, Dept Radiol, Dept Med & Hlth Sci, Ctr Med Image Sci & Visualizat CMIV, S-58185 Linkoping, Sweden
[2] Linkoping Univ, Dept Med & Hlth Sci, Dept Med Phys, Linkoping, Sweden
[3] KTH Royal Inst, STH, Stockholm, Sweden
[4] Linkoping Univ, Dept Med & Hlth Sci, S-58183 Linkoping, Sweden
关键词
Dose; Computed tomography; Iterative reconstruction; Abdomen; FBP; FILTERED BACK-PROJECTION; COMPUTED-TOMOGRAPHY; ALGORITHM; PHANTOM; MBIR;
D O I
10.1007/s00330-017-5113-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To estimate potential dose reduction in abdominal CT by visually comparing images reconstructed with filtered back projection (FBP) and strengths of 3 and 5 of a specific MBIR. A dual-source scanner was used to obtain three data sets each for 50 recruited patients with 30, 70 and 100% tube loads (mean CTDIvol 1.9, 3.4 and 6.2 mGy). Six image criteria were assessed independently by five radiologists. Potential dose reduction was estimated with Visual Grading Regression (VGR). Comparing 30 and 70% tube load, improved image quality was observed as a significant strong effect of log tube load and reconstruction method with potential dose reduction relative to FBP of 22-47% for MBIR strength 3 (p < 0.001). For MBIR strength 5 no dose reduction was possible for image criteria 1 (liver parenchyma), but dose reduction between 34 and 74% was achieved for other criteria. Interobserver reliability showed agreement of 71-76% (kappa (w) 0.201-0.286) and intra-observer reliability of 82-96% (kappa (w) 0.525-0.783). MBIR showed improved image quality compared to FBP with positive correlation between MBIR strength and increasing potential dose reduction for all but one image criterion. aEuro cent MBIR's main advantage is its de-noising properties, which facilitates dose reduction. aEuro cent MBIR allows for potential dose reduction in relation to FBP. aEuro cent Visual Grading Regression (VGR) produces direct numerical estimates of potential dose reduction. aEuro cent MBIR strengths 3 and 5 dose reductions were 22-34 and 34-74%. aEuro cent MBIR strength 5 demonstrates inferior performance for liver parenchyma.
引用
收藏
页码:2464 / 2473
页数:10
相关论文
共 50 条
  • [21] Assessment of the dose reduction potential of a model-based iterative reconstruction algorithm using a task-based performance metrology
    Samei, Ehsan
    Richard, Samuel
    [J]. MEDICAL PHYSICS, 2015, 42 (01) : 314 - 323
  • [22] Radiation dose reduction and image quality in pediatric abdominal CT with kVp and mAs modulation and an iterative reconstruction technique
    Kim, Jun-Hwee
    Kim, Myung-Joon
    Kim, Ha Yan
    Lee, Mi-Jung
    [J]. CLINICAL IMAGING, 2014, 38 (05) : 710 - 714
  • [23] Deep learning versus iterative reconstruction on image quality and dose reduction in abdominal CT: a live animal study
    Zhang, Jason Z.
    Ganesh, Halemane
    Raslau, Flavius D.
    Nair, Rashmi
    Escott, Edward
    Wang, Chi
    Wang, Ge
    Zhang, Jie
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (14):
  • [24] Image quality improvement using model-based iterative reconstruction in low dose chest CT for children with necrotizing pneumonia
    Sun, Jihang
    Yu, Tong
    Liu, Jinrong
    Duan, Xiaomin
    Hu, Di
    Liu, Yong
    Peng, Yun
    [J]. BMC MEDICAL IMAGING, 2017, 17
  • [25] Image quality improvement using model-based iterative reconstruction in low dose chest CT for children with necrotizing pneumonia
    Jihang Sun
    Tong Yu
    Jinrong Liu
    Xiaomin Duan
    Di Hu
    Yong liu
    Yun Peng
    [J]. BMC Medical Imaging, 17
  • [26] Image quality assessment of an iterative reconstruction algorithm applied to abdominal CT imaging
    Funama, Yoshinori
    Taguchi, Katsuyuki
    Utsunomiya, Daisuke
    Oda, Seitaro
    Katahira, Kazuhiro
    Tokuyasu, Shinichi
    Yamashita, Yasuyuki
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (04): : 527 - 534
  • [27] Dose reduction in CT urography and vasculature phantom studies using model-based iterative reconstruction
    Page, Leland
    Wei, Wei
    Kundra, Vikas
    Rong, X. John
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 334 - 342
  • [28] Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR)
    S. Notohamiprodjo
    Z. Deak
    F. Meurer
    F. Maertz
    F. G. Mueck
    L. L. Geyer
    S. Wirth
    [J]. European Radiology, 2015, 25 : 140 - 146
  • [29] Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique
    Masaki Katsura
    Izuru Matsuda
    Masaaki Akahane
    Jiro Sato
    Hiroyuki Akai
    Koichiro Yasaka
    Akira Kunimatsu
    Kuni Ohtomo
    [J]. European Radiology, 2012, 22 : 1613 - 1623
  • [30] Hybrid iterative reconstruction algorithm in brain CT: a radiation dose reduction and image quality assessment study
    Love, Askell
    Siemund, Roger
    Hoglund, Peter
    Van Westen, Danielle
    Stenberg, Lars
    Petersen, Cecilia
    Bjorkman-Burtscher, Isabella M.
    [J]. ACTA RADIOLOGICA, 2014, 55 (02) : 208 - 217