A study of the spectroscopic performance of a CdTe microstrip detector

被引:5
|
作者
Dusi, W [1 ]
Auricchio, N
Brigliadori, L
Cola, A
Donati, A
Landini, G
Mengoni, D
Perillo, E
Siffert, P
Ventura, G
机构
[1] IASF, CNR, Sez Bologna, Ist Nazl Fis Nucl, I-40129 Bologna, Italy
[2] Sez Bologna, I-40129 Bologna, Italy
[3] Univ Bologna, Dept Phys, I-40127 Bologna, Italy
[4] Sez Lecce, IMM, CNR, I-73100 Lecce, Italy
[5] Univ Naples Federico II, Dept Phys, I-80126 Naples, Italy
[6] Ist Nazl Fis Nucl, I-80126 Naples, Italy
[7] CNRS, Lab PHASE, F-67037 Strasbourg, France
关键词
CdTe spectrometer; microstrip detectors; semiconductor detectors; various irradiation angles; X- and gamma-ray spectroscopy;
D O I
10.1109/TNS.2003.815170
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A study of the spectroscopic performance of a CdTe detector, equipped with A "strip anode" placed between two parallel focusing strips, was carried out. The focusing strips were kept at an intermediate bias voltage with respect to anode and cathode. This configuration increases the intensity and focuses the weighing field on the region surrounding the strip anode, thus improving the uniformity of signals due to the collection of electrons. The detector was irradiated with a narrow photon beam emitted, by a Co-57 source. When the. photon beam is impinging perpendicularly to the cathode plane, the spectroscopic response of the strip anode detector looks better than that obtained by the usual "full anode" CdTe detectors, especially with regard to the photopeak in the 122-keV energy region. Previous measurements carried out on detectors having the same crystal size, but equipped with a full anode, showed a considerable improvement in spectroscopic performance at 122 keV, when the photon beam was impinging on the detector at almost grazing angle with respect to the cathode surface [1]. In-this paper, a similar set of measurements at variable angle of the photon beam is carried out on detectors having strip anode configuration in order to investigate their behavior under the same experimental conditions.
引用
收藏
页码:1026 / 1030
页数:5
相关论文
共 50 条
  • [1] A study of the spectroscopic performance of a CdTe microstrip detector.
    Dusi, W
    Auricchio, N
    Brigliadori, L
    Cola, A
    Donati, A
    Landini, G
    Mengoni, D
    Perillo, E
    Siffert, P
    Ventura, G
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 494 - 499
  • [2] Spectroscopic response of a CdTe microstrip detector when irradiated at various impinging angles
    Perillo, E
    Cola, A
    Donati, A
    Dusi, W
    Landini, G
    Raulo, A
    Ventura, G
    Vitulli, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (1-2): : 125 - 133
  • [3] Imaging and spectroscopic performance studies of pixellated CdTe Timepix detector
    Maneuski, D.
    Astromskas, V.
    Frojdh, E.
    Frojdh, C.
    Gimenez, E. N.
    Marchal, J.
    O'Shea, V.
    Stewart, G.
    Tartoni, N.
    Wilhelm, H.
    Wraight, K.
    Zain, R. M.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [4] Investigations on performance and spectroscopic capabilities of a 3 mm CdTe Timepix detector
    Fey, Julian
    Procz, Simon
    Schuetz, Michael K.
    Fiederle, Michael
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 977
  • [5] PERFORMANCE OF CDTE AS A GAMMA SPECTROMETER AND DETECTOR
    ZANIO, K
    NEELAND, J
    MONTANO, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1970, NS17 (03) : 287 - &
  • [6] The role of defects on CdTe detector performance
    Sellin, P
    Özsan, ME
    Hoxley, D
    Lohstroh, A
    Siffert, P
    Sowinska, M
    Simon, A
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3306 - 3310
  • [7] The CdTe detector module and its imaging performance
    Issei Mori
    Takuzo Takayama
    Nobutoku Motomura
    Annals of Nuclear Medicine, 2001, 15 : 487 - 494
  • [8] Characterization of a CdTe microstrip detector as a hard X ray focal plane prototype
    Caroli, E
    Auriccho, N
    Donati, A
    Schiavone, F
    Stephen, JB
    Ventura, G
    Del Sordo, S
    Agnetta, G
    Russo, F
    Zora, M
    Bertuccio, G
    Caccia, S
    Sampietro, M
    Gombia, E
    Pareschi, G
    Negri, B
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4378 - 4382
  • [9] The CdTe detector module and its imaging performance
    Mori, I
    Takayama, T
    Motomura, N
    ANNALS OF NUCLEAR MEDICINE, 2001, 15 (06) : 487 - 494
  • [10] Performance characteristics of CdTe drift ring detector
    Alruhaili, A.
    Sellin, P. J.
    Lohstroh, A.
    Veeramani, P.
    Kazemi, S.
    Veale, M. C.
    Sawhney, K. J. S.
    Kachkanov, V.
    JOURNAL OF INSTRUMENTATION, 2014, 9