A study of the spectroscopic performance of a CdTe microstrip detector

被引:5
|
作者
Dusi, W [1 ]
Auricchio, N
Brigliadori, L
Cola, A
Donati, A
Landini, G
Mengoni, D
Perillo, E
Siffert, P
Ventura, G
机构
[1] IASF, CNR, Sez Bologna, Ist Nazl Fis Nucl, I-40129 Bologna, Italy
[2] Sez Bologna, I-40129 Bologna, Italy
[3] Univ Bologna, Dept Phys, I-40127 Bologna, Italy
[4] Sez Lecce, IMM, CNR, I-73100 Lecce, Italy
[5] Univ Naples Federico II, Dept Phys, I-80126 Naples, Italy
[6] Ist Nazl Fis Nucl, I-80126 Naples, Italy
[7] CNRS, Lab PHASE, F-67037 Strasbourg, France
关键词
CdTe spectrometer; microstrip detectors; semiconductor detectors; various irradiation angles; X- and gamma-ray spectroscopy;
D O I
10.1109/TNS.2003.815170
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A study of the spectroscopic performance of a CdTe detector, equipped with A "strip anode" placed between two parallel focusing strips, was carried out. The focusing strips were kept at an intermediate bias voltage with respect to anode and cathode. This configuration increases the intensity and focuses the weighing field on the region surrounding the strip anode, thus improving the uniformity of signals due to the collection of electrons. The detector was irradiated with a narrow photon beam emitted, by a Co-57 source. When the. photon beam is impinging perpendicularly to the cathode plane, the spectroscopic response of the strip anode detector looks better than that obtained by the usual "full anode" CdTe detectors, especially with regard to the photopeak in the 122-keV energy region. Previous measurements carried out on detectors having the same crystal size, but equipped with a full anode, showed a considerable improvement in spectroscopic performance at 122 keV, when the photon beam was impinging on the detector at almost grazing angle with respect to the cathode surface [1]. In-this paper, a similar set of measurements at variable angle of the photon beam is carried out on detectors having strip anode configuration in order to investigate their behavior under the same experimental conditions.
引用
收藏
页码:1026 / 1030
页数:5
相关论文
共 50 条
  • [41] X-ray micro-beam characterization of a small pixel spectroscopic CdTe detector
    Veale, M. C.
    Bell, S. J.
    Seller, P.
    Wilson, M. D.
    Kachkanov, V.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [42] A 10 cm x 10 cm CdTe Spectroscopic Imaging Detector based on the HEXITEC ASIC
    Wilson, M. D.
    Dummott, L.
    Duarte, D. D.
    Green, F. H.
    Pani, S.
    Schneider, A.
    Scuffham, J. W.
    Seller, P.
    Veale, M. C.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [43] Comparing performances of a CdTe X-ray spectroscopic detector and an X-ray dual-energy sandwich detector
    Gorecki, A.
    Brambilla, A.
    Moulin, V.
    Gaborieau, E.
    Radisson, P.
    Verger, L.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [44] PERFORMANCE OF A SILICON MICROSTRIP DETECTOR WITH A NEW TYPE OF PREAMPLIFIER FOR NUCLEAR EXPERIMENTS
    TANAKA, M
    ARAI, I
    MANABE, A
    NINOMIYA, M
    NUNOKAWA, H
    TOMIZAWA, K
    YAGI, K
    CHIBA, J
    KOBAYASHI, T
    NAGAE, T
    SANO, H
    TOKUSHUKU, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 284 (2-3): : 296 - 302
  • [45] PERFORMANCE OF A SILICON MICROSTRIP DETECTOR IN A VERY HIGH-RATE ENVIRONMENT
    MCMANUS, A
    BODEN, A
    CHEN, TY
    COOPER, M
    COX, B
    FORTNEY, L
    GOLOVATYUK, V
    HANLET, P
    KOWALD, W
    MAZUR, P
    NELSON, K
    RAMACHANDRAN, S
    RECAGNI, M
    SEGAL, J
    SELOVE, W
    SMITH, R
    SUN, J
    TRISCHUK, J
    VANBERG, R
    YAO, N
    ZOU, B
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (05) : 1249 - 1253
  • [46] THE ELECTROSTATIC-FIELD IN MICROSTRIP CHAMBERS AND ITS INFLUENCE ON DETECTOR PERFORMANCE
    FLORENT, JJ
    GAUDAEN, J
    ROPELEWSKI, L
    SAULI, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 329 (1-2): : 125 - 132
  • [47] Optimization of high resolution collimator with CdTe detector : a simulation study
    Lee, Young-Jin
    Kim, Hee-Joung
    Ryu, Hyun-Ju
    Cho, Hyo-Min
    Lee, Seung-Wan
    Choi, Yu-Na
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [48] A NEW INTRAOPERATIVE CDTE DETECTOR
    HOSSEINFOUCHER, C
    ROUSSEAU, J
    LECOUFFE, P
    REGAL, R
    CARNAILLE, B
    VENEL, H
    PROYE, C
    MARCHANDISE, X
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1988, 14 (5-6): : 226 - 226
  • [49] Spectroscopic and electrochemical study of CdTe nanocrystals capped with thiol mixtures
    Matos, Charlene R. S.
    Souza, Helio O., Jr.
    Candido, Luan P. M.
    Costa, Luiz P.
    Santos, Francisco A.
    Alencar, Marcio A. R. C.
    Abegao, Luis M. G.
    Rodrigues, Jose J., Jr.
    Sussuchi, Eliana Midori
    Gimenez, Iara F.
    MATERIALS RESEARCH EXPRESS, 2016, 3 (06):
  • [50] AUGER SPECTROSCOPIC STUDY AND PHOTOELECTROCHEMICAL RESPONSE OF CATHODICALLY ELECTRODEPOSITED CDTE
    SOLORZAFERIA, O
    LOAEZAMARTINEZ, P
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 195 : 136 - PHYS