A study of the spectroscopic performance of a CdTe microstrip detector

被引:5
|
作者
Dusi, W [1 ]
Auricchio, N
Brigliadori, L
Cola, A
Donati, A
Landini, G
Mengoni, D
Perillo, E
Siffert, P
Ventura, G
机构
[1] IASF, CNR, Sez Bologna, Ist Nazl Fis Nucl, I-40129 Bologna, Italy
[2] Sez Bologna, I-40129 Bologna, Italy
[3] Univ Bologna, Dept Phys, I-40127 Bologna, Italy
[4] Sez Lecce, IMM, CNR, I-73100 Lecce, Italy
[5] Univ Naples Federico II, Dept Phys, I-80126 Naples, Italy
[6] Ist Nazl Fis Nucl, I-80126 Naples, Italy
[7] CNRS, Lab PHASE, F-67037 Strasbourg, France
关键词
CdTe spectrometer; microstrip detectors; semiconductor detectors; various irradiation angles; X- and gamma-ray spectroscopy;
D O I
10.1109/TNS.2003.815170
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A study of the spectroscopic performance of a CdTe detector, equipped with A "strip anode" placed between two parallel focusing strips, was carried out. The focusing strips were kept at an intermediate bias voltage with respect to anode and cathode. This configuration increases the intensity and focuses the weighing field on the region surrounding the strip anode, thus improving the uniformity of signals due to the collection of electrons. The detector was irradiated with a narrow photon beam emitted, by a Co-57 source. When the. photon beam is impinging perpendicularly to the cathode plane, the spectroscopic response of the strip anode detector looks better than that obtained by the usual "full anode" CdTe detectors, especially with regard to the photopeak in the 122-keV energy region. Previous measurements carried out on detectors having the same crystal size, but equipped with a full anode, showed a considerable improvement in spectroscopic performance at 122 keV, when the photon beam was impinging on the detector at almost grazing angle with respect to the cathode surface [1]. In-this paper, a similar set of measurements at variable angle of the photon beam is carried out on detectors having strip anode configuration in order to investigate their behavior under the same experimental conditions.
引用
收藏
页码:1026 / 1030
页数:5
相关论文
共 50 条
  • [31] CDTE AS A GAMMA DETECTOR
    AKUTAGAWA, W
    ZANIO, K
    MAYER, JW
    NUCLEAR INSTRUMENTS & METHODS, 1967, 55 (02): : 383 - +
  • [32] DETECTOR CAPACITANCE OF SILICON MICROSTRIP DETECTOR
    IKEDA, H
    TANAKA, M
    OKUNO, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 313 (1-2): : 31 - 36
  • [33] Feasibility study of a gas microstrip detector for medical applications
    Giakos, GC
    Chowdhury, S
    Vedantham, S
    Dasgupta, A
    Pillai, B
    Ghotra, P
    Suryanarayanan, S
    Odogba, J
    PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 459 - 468
  • [34] THE SILICON MICROSTRIP DETECTOR
    LITKE, AM
    SCHWARZ, AS
    SCIENTIFIC AMERICAN, 1995, 272 (05) : 76 - 81
  • [35] VERTEX MICROSTRIP DETECTOR
    GREBENEV, VN
    DZHELYADIN, RI
    KARYUKHIN, AN
    KONOPLYANNIKOV, AK
    KOPIKOV, SV
    LOGINOV, AI
    MALOLETNEV, AA
    MIKAELYAN, AL
    PICHUGIN, AP
    POROSHIN, NO
    SHISHKOV, AV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1994, 37 (02) : 146 - 149
  • [36] Basic performance and stability of a CdTe solid-state detector panel
    Katsutoshi Tsuchiya
    Isao Takahashi
    Tsuneaki Kawaguchi
    Kazuma Yokoi
    Yuuichi Morimoto
    Takafumi Ishitsu
    Atsurou Suzuki
    Yuuichirou Ueno
    Keiji Kobashi
    Annals of Nuclear Medicine, 2010, 24 : 301 - 311
  • [37] Performance of CdTe detector in the 13-1333 keV energy range
    Demir, Demet
    Onder, Pinar
    Oznuluer, Tuba
    RADIATION PHYSICS AND CHEMISTRY, 2010, 79 (11) : 1132 - 1136
  • [38] Basic performance and stability of a CdTe solid-state detector panel
    Tsuchiya, Katsutoshi
    Takahashi, Isao
    Kawaguchi, Tsuneaki
    Yokoi, Kazuma
    Morimoto, Yuuichi
    Ishitsu, Takafumi
    Suzuki, Atsurou
    Ueno, Yuuichirou
    Kobashi, Keiji
    ANNALS OF NUCLEAR MEDICINE, 2010, 24 (04) : 301 - 311
  • [39] Performance of multichannel FX chip with DC coupled CdTe Schottky detector
    Kachel, M.
    Grybos, P.
    MIXDES 2008: PROCEEDINGS OF THE 15TH INTERNATIONAL CONFERENCE ON MIXED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2008, : 277 - 280
  • [40] PHOTOMETRIC AND SPECTROSCOPIC PERFORMANCE OF A THINNED RCA CCD DETECTOR
    LEACH, RW
    ADVANCES IN ELECTRONICS AND ELECTRON PHYSICS, 1985, 64 : 177 - 184