A study of the spectroscopic performance of a CdTe microstrip detector

被引:5
|
作者
Dusi, W [1 ]
Auricchio, N
Brigliadori, L
Cola, A
Donati, A
Landini, G
Mengoni, D
Perillo, E
Siffert, P
Ventura, G
机构
[1] IASF, CNR, Sez Bologna, Ist Nazl Fis Nucl, I-40129 Bologna, Italy
[2] Sez Bologna, I-40129 Bologna, Italy
[3] Univ Bologna, Dept Phys, I-40127 Bologna, Italy
[4] Sez Lecce, IMM, CNR, I-73100 Lecce, Italy
[5] Univ Naples Federico II, Dept Phys, I-80126 Naples, Italy
[6] Ist Nazl Fis Nucl, I-80126 Naples, Italy
[7] CNRS, Lab PHASE, F-67037 Strasbourg, France
关键词
CdTe spectrometer; microstrip detectors; semiconductor detectors; various irradiation angles; X- and gamma-ray spectroscopy;
D O I
10.1109/TNS.2003.815170
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A study of the spectroscopic performance of a CdTe detector, equipped with A "strip anode" placed between two parallel focusing strips, was carried out. The focusing strips were kept at an intermediate bias voltage with respect to anode and cathode. This configuration increases the intensity and focuses the weighing field on the region surrounding the strip anode, thus improving the uniformity of signals due to the collection of electrons. The detector was irradiated with a narrow photon beam emitted, by a Co-57 source. When the. photon beam is impinging perpendicularly to the cathode plane, the spectroscopic response of the strip anode detector looks better than that obtained by the usual "full anode" CdTe detectors, especially with regard to the photopeak in the 122-keV energy region. Previous measurements carried out on detectors having the same crystal size, but equipped with a full anode, showed a considerable improvement in spectroscopic performance at 122 keV, when the photon beam was impinging on the detector at almost grazing angle with respect to the cathode surface [1]. In-this paper, a similar set of measurements at variable angle of the photon beam is carried out on detectors having strip anode configuration in order to investigate their behavior under the same experimental conditions.
引用
收藏
页码:1026 / 1030
页数:5
相关论文
共 50 条
  • [21] Influence of trapping on silicon microstrip detector design and performance
    Kramberger, G
    Cindro, V
    Mandic, I
    Mikuz, M
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 909 - 913
  • [22] Comparison of a Large Area CZT Detector to a Spectroscopic CdTe Detector for X-ray Fluorescence Computed 'Tomography
    Vernekohl, Don
    Streicher, Michael
    Ahmad, Moiz
    Xing, Lei
    He, Zhong
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [23] Growth and fabrication method of CdTe and its performance as a radiation detector
    Park S.
    Kim H.
    Kim D.
    Journal of the Korean Physical Society, 2015, 66 (1) : 31 - 36
  • [24] Growth and fabrication method of CdTe and its performance as a radiation detector
    Choi, Hyojeong
    Jeong, Manhee
    Kim, Han Soo
    Kim, Young Soo
    Ha, Jang Ho
    Chai, Jong-Seo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 66 (01) : 27 - 30
  • [25] Performance limits of a 55-μm pixel CdTe detector
    Pellegrini, G
    Chmeissani, M
    Maiorino, M
    Blanchot, G
    Garcia, J
    Lozano, M
    Martinez, R
    Puigdengoles, C
    Ullan, M
    Casado, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 361 - 366
  • [26] Growth and fabrication method of CdTe and its performance as a radiation detector
    Hyojeong Choi
    Manhee Jeong
    Han Soo Kim
    Young Soo Kim
    Jang Ho Ha
    Jong-Seo Chai
    Journal of the Korean Physical Society, 2015, 66 : 27 - 30
  • [27] Gamma spectroscopic measurements using the PID350 pixelated CdTe radiation detector
    Karafasoulis, K.
    Zachariadou, K.
    Seferlis, S.
    Papadakis, I.
    Loukas, D.
    Lambropoulos, C.
    Potiriadis, C.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3816 - 3820
  • [28] Simulation studies and spectroscopic measurements of a position sensitive detector based on pixelated CdTe crystals
    Karafasoulis, K.
    Zachariadou, K.
    Seferlis, S.
    Kaissas, I.
    Lambropoulos, C.
    Loukas, D.
    Potiriadis, C.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1108 - 1113
  • [29] Fast CdTe and CdZnTe Semiconductor Detector Arrays for Spectroscopic X-Ray Imaging
    Brambilla, Andrea
    Ouvrier-Buffet, P.
    Gonon, G.
    Rinkel, J.
    Moulin, V.
    Boudou, C.
    Verger, L.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (01) : 408 - 415
  • [30] Electrostatic field in microstrip chambers and its influence on detector performance
    Florent, J.J.
    Gaudaen, J.
    Ropelewski, L.
    Sauli, F.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993, A329 (1-2) : 125 - 132