Navigator-echo-base real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography

被引:304
|
作者
Wang, Y [1 ]
Rossman, PJ [1 ]
Grimm, RC [1 ]
Riederer, SJ [1 ]
Ehman, RL [1 ]
机构
[1] MAYO CLIN & MAYO FDN, DEPT DIAGNOST RADIOL, ROCHESTER, MN 55905 USA
关键词
coronary vessels; MR; magnetic resonance (MR); artifact; motion correction; vascular studies;
D O I
10.1148/radiology.198.1.8539406
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To test the hypothesis that respiration effects in three-dimensional (3D) coronary magnetic resonance (MR) imaging can be reduced with navigator-echo-based gating or triggering according to the superior-inferior position of the diaphragm. MATERIALS AND METHODS: Realtime respiratory gating and respiratory triggering (breath hold with feedback) were implemented with navigator echoes in a magnetization-prepared, segmented, 3D coronary imaging sequence. The two techniques were first tested with a motion phantom. An imaging protocol that compared real-time respiratory-gated acquisition, real-time respiratory-triggered acquisition, and continuous acquisition was then evaluated in six healthy subjects. RESULTS: Real-time respiratory-gated and respiratory-triggered acquisition were superior to continuous acquisition with two signals averaged (P = .025). The performance of the gated acquisition was about the same as that of the triggered acquisition (P = .05). CONCLUSION: Navigator-echo-based, real-time respiratory-gating and respiratory-triggering techniques are practical methods for effective reduction of respiration effects in coronary MR imaging.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 50 条
  • [1] Navigator echo-based respiratory gating for three-dimensional MR coronary angiography: Reduction of scan time using a slice interpolation technique
    Nikolaou, K
    Huber, A
    Knez, A
    Scheidler, J
    Petsch, R
    Reiser, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (03) : 378 - 387
  • [2] Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: Comparison of navigator locations
    Stuber, M
    Botnar, RM
    Danias, PG
    Kissinger, KV
    Manning, WJ
    RADIOLOGY, 1999, 212 (02) : 579 - 587
  • [3] Three-dimensional pulmonary artery MR angiography with real-time navigator gating and selective IR preparation
    Wang, Y
    Rossman, PJ
    Grimm, RC
    Wilman, AH
    Riederer, SJ
    Ehman, RL
    RADIOLOGY, 1996, 201 : 558 - 558
  • [4] Coronary artery imaging with real-time navigator three-dimensional turbo-field-echo MR coronary angiography: Initial experience
    Bogaert, J
    Kuzo, R
    Dymarkowski, S
    Beckers, R
    Piessens, J
    Rademakers, FE
    RADIOLOGY, 2003, 226 (03) : 707 - 716
  • [5] Navigator echo-based respiratory gating for three-dimensional MR coronary angiography: Results from healthy volunteers and patients with proximal coronary artery stenoses
    Huber, A
    Nikolaou, K
    Gonschior, P
    Knez, A
    Stehling, M
    Reiser, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (01) : 95 - 101
  • [6] Three-dimensional coronary artery MR imaging using prospective real-time respiratory navigator and linear phase shift processing: Comparison with conventional coronary angiography
    Lethimonnier, F
    Furber, A
    Morel, O
    Geslin, P
    L'Hoste, P
    Tadei, A
    Jallet, P
    Caron-Poitreau, C
    Le Jeune, JJ
    MAGNETIC RESONANCE IMAGING, 1999, 17 (08) : 1111 - 1120
  • [7] Breathhold three-dimensional coronary magnetic resonance angiography using real-time navigator technology
    Stuber, M
    Botnar, RM
    Danias, PG
    Kissinger, KV
    Manning, WJ
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 1999, 1 (03) : 233 - 238
  • [8] Navigator-echo-based respiratory gating for 3D-MR coronary angiography
    Valassis, G
    Nikolaou, K
    Gonschior, P
    Huber, A
    Reiser, M
    EUROPEAN HEART JOURNAL, 2000, 21 : 509 - 509
  • [9] Three-dimensional MR coronary angiography using the navigator technique compared with conventional coronary angiography
    Sandstede, JJW
    Pabst, T
    Beer, M
    Geis, N
    Kenn, W
    Neubauer, S
    Hahn, D
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (01) : 135 - 139
  • [10] Three-dimensional MR coronary angiography in navigator-technique: Comparison with conventional angiography
    Sandstede, J
    Pabst, T
    Beer, MJ
    Kenn, W
    Neubauer, S
    Hahn, D
    RADIOLOGY, 1997, 205 : 54 - 54