Navigator echo-based respiratory gating for three-dimensional MR coronary angiography: Results from healthy volunteers and patients with proximal coronary artery stenoses

被引:55
|
作者
Huber, A
Nikolaou, K
Gonschior, P
Knez, A
Stehling, M
Reiser, M
机构
[1] Univ Munich, Klinikum Grosshadern, Dept Diagnost Radiol, Inst Radiol Diagnostik, D-81377 Munich, Germany
[2] Univ Munich, Klinikum Grosshadern, Dept Internal Med 1, Inst Radiol Diagnostik, D-81377 Munich, Germany
[3] Tech Univ Munich, Klinikum Rechts Isar, Deutsch Herzzentrum, D-80335 Munich, Germany
[4] Tech Univ Munich, Klinikum Rechts Isar, Med Klin 1, D-80335 Munich, Germany
关键词
D O I
10.2214/ajr.173.1.10397107
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to investigate the value of respiratory-gated three-dimensional (3D) MR angiography in identifying coronary arteries in healthy volunteers and in patients with proximal coronary artery stenosis and to compare the results with those of conventional coronary angiography. SUBJECTS AND METHODS. Twenty healthy volunteers and 20 patients with coronary artery stenosis were examined on a 1.5-T scanner with a retrospectively respiratory-gated 3D gradient-echo sequence. Visualization of the main coronary arteries was analyzed after curved multiplanar reconstructions. A six-point grading system was used to evaluate 400 vessel segments. The assessment of stenosis was performed by two observers who were unaware of the results of conventional coronary angiography. RESULTS. The proximal, middle, and distal segments of the coronary arteries were completely identified with or without luminal irregularities in 55%, 47%, and 20%, respectively, of the healthy volunteers. For the 20 patients, results were 69%, 44%, and 20%, respectively. For the assessment of coronary artery stenoses (n = 53), sensitivity was 73% and specificity was 50% after evaluation of the MR angiograms of all patients. A sensitivity of 79% and a specificity of 54% were found for evaluation of the MR coronary angiograms, with an image quality score of at least 3 (i.e., artery segments completely identified with major luminal irregularities). CONCLUSION. With the navigator echo MR imaging technique, a complete 3D visualization of the main coronary arteries was possible in cases with high image quality. However, further experience with and improvement of the navigator echo technique we used is necessary for reliable assessment of coronary artery stenosis.
引用
收藏
页码:95 / 101
页数:7
相关论文
共 50 条
  • [1] Navigator echo-based respiratory gating for three-dimensional MR coronary angiography: Reduction of scan time using a slice interpolation technique
    Nikolaou, K
    Huber, A
    Knez, A
    Scheidler, J
    Petsch, R
    Reiser, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (03) : 378 - 387
  • [2] Experience with navigator-echo-based respiratory gating in healthy volunteers and in patients with proximal coronary artery stenosis
    Huber, AM
    Balci, C
    Wintersperger, BJ
    Smekal, AV
    Gonschior, P
    Reiser, MF
    RADIOLOGY, 1997, 205 : 56 - 56
  • [3] Three-dimensional, navigator-echo MR coronary angiography in detecting stenoses of the major epicardial vessels, with conventional coronary angiography as the standard of reference
    Sardanelli, F
    Molinari, G
    Zandrino, F
    Balbi, M
    RADIOLOGY, 2000, 214 (03) : 808 - 814
  • [4] Navigator-echo-based respiratory gating for 3D-MR coronary angiography
    Valassis, G
    Nikolaou, K
    Gonschior, P
    Huber, A
    Reiser, M
    EUROPEAN HEART JOURNAL, 2000, 21 : 509 - 509
  • [5] Three-dimensional coronary MR angiography with the navigator technique: Imaging of the proximal course of anomalous coronary arteries
    Sandstede, J
    Pabst, T
    Beer, M
    Kellner, M
    Kenn, W
    Neubauer, S
    Hahn, D
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 169 (04): : 432 - 436
  • [6] Navigator-echo-base real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography
    Wang, Y
    Rossman, PJ
    Grimm, RC
    Riederer, SJ
    Ehman, RL
    RADIOLOGY, 1996, 198 (01) : 55 - 60
  • [7] Comparison of two-dimensional breath-hold coronary MR angiography, three-dimensional coronary MR angiography in navigator technique, and conventional coronary angiography in patients with coronary artery disease
    Lentschig, MG
    Hoeffgen, M
    Wichter, T
    Reimer, P
    Rummeny, EJ
    RADIOLOGY, 1998, 209P : 305 - 305
  • [8] Proximal coronary artery stenosis: Three-dimensional MRI with fat saturation and navigator echo
    Muller, MF
    Fleisch, M
    Kroeker, R
    Chatterjee, T
    Meier, B
    Vock, P
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (04) : 644 - 651
  • [9] Three-dimensional MR coronary angiography using the navigator technique compared with conventional coronary angiography
    Sandstede, JJW
    Pabst, T
    Beer, M
    Geis, N
    Kenn, W
    Neubauer, S
    Hahn, D
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (01) : 135 - 139
  • [10] Three-dimensional MR coronary angiography with the navigator technique for primary diagnosis of coronary artery disease: Comparison with conventional coronary angiography.
    Sandstede, J
    Pabst, T
    Kenn, W
    Beer, M
    Neubauer, S
    Hahn, D
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (03): : 269 - 274