Navigator-echo-based respiratory gating for 3D-MR coronary angiography

被引:0
|
作者
Valassis, G
Nikolaou, K
Gonschior, P
Huber, A
Reiser, M
机构
[1] Tech Univ Munich, Deutsches Herzzentrum, D-8000 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Med Klin 1, D-8000 Munich, Germany
[3] Univ Munich, Dept Radiol, Munich, Germany
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
P2786
引用
收藏
页码:509 / 509
页数:1
相关论文
共 50 条
  • [1] Experience with navigator-echo-based respiratory gating in healthy volunteers and in patients with proximal coronary artery stenosis
    Huber, AM
    Balci, C
    Wintersperger, BJ
    Smekal, AV
    Gonschior, P
    Reiser, MF
    RADIOLOGY, 1997, 205 : 56 - 56
  • [2] A comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiography
    Du, YPP
    McVeigh, ER
    Bluemke, DA
    Silber, HA
    Foo, TKF
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2001, 17 (04): : 287 - 294
  • [3] A comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiography
    Yiping P. Du
    Elliot R. McVeigh
    David A. Bluemke
    Harry A. Silber
    Thomas K.F. Foo
    The International Journal of Cardiovascular Imaging, 2001, 17 : 287 - 294
  • [4] A comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiography - Editorial comment
    Bunce, NH
    Jhooti, P
    Underwood, SR
    Pennell, DJ
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2001, 17 (04): : 295 - 296
  • [5] Repeated 3D coronary MR angiography with navigator echo gating: Technical quality and consistency of image interpretation
    Ikonen, AEJ
    Manninen, HI
    Vainio, P
    Hirvonen, TPJ
    Vanninen, RL
    Matsi, PJ
    Hartikainen, JEK
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (03) : 375 - 381
  • [6] Prospective navigator gating with a dual acceptance window technique to reduce respiratory motion artifacts in 3D MR coronary angiography
    Yiping P. Du
    The International Journal of Cardiovascular Imaging, 2003, 19 : 157 - 162
  • [7] Prospective navigator gating with a dual acceptance window technique to reduce respiratory motion artifacts in 3D MR coronary angiography
    Du, YPP
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2003, 19 (02): : 157 - 162
  • [8] Navigator echo-based respiratory gating for three-dimensional MR coronary angiography: Reduction of scan time using a slice interpolation technique
    Nikolaou, K
    Huber, A
    Knez, A
    Scheidler, J
    Petsch, R
    Reiser, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (03) : 378 - 387
  • [9] Imaging of an aberrant right coronary artery with retrospective respiratory-gated 3D-MR angiography
    Kalinkin, OM
    Woodard, PK
    Ludbrook, PA
    Gutierrez, FR
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2001, 17 (01): : 61 - 64
  • [10] Imaging of an aberrant right coronary artery with retrospective respiratory-gated 3D-MR angiography
    Olga M. Kalinkin
    Pamela K. Woodard
    Philip A. Ludbrook
    Fernando R. Gutierrez
    The International Journal of Cardiovascular Imaging, 2001, 17 : 61 - 64