Navigator-echo-base real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography

被引:304
|
作者
Wang, Y [1 ]
Rossman, PJ [1 ]
Grimm, RC [1 ]
Riederer, SJ [1 ]
Ehman, RL [1 ]
机构
[1] MAYO CLIN & MAYO FDN, DEPT DIAGNOST RADIOL, ROCHESTER, MN 55905 USA
关键词
coronary vessels; MR; magnetic resonance (MR); artifact; motion correction; vascular studies;
D O I
10.1148/radiology.198.1.8539406
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To test the hypothesis that respiration effects in three-dimensional (3D) coronary magnetic resonance (MR) imaging can be reduced with navigator-echo-based gating or triggering according to the superior-inferior position of the diaphragm. MATERIALS AND METHODS: Realtime respiratory gating and respiratory triggering (breath hold with feedback) were implemented with navigator echoes in a magnetization-prepared, segmented, 3D coronary imaging sequence. The two techniques were first tested with a motion phantom. An imaging protocol that compared real-time respiratory-gated acquisition, real-time respiratory-triggered acquisition, and continuous acquisition was then evaluated in six healthy subjects. RESULTS: Real-time respiratory-gated and respiratory-triggered acquisition were superior to continuous acquisition with two signals averaged (P = .025). The performance of the gated acquisition was about the same as that of the triggered acquisition (P = .05). CONCLUSION: Navigator-echo-based, real-time respiratory-gating and respiratory-triggering techniques are practical methods for effective reduction of respiration effects in coronary MR imaging.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 50 条
  • [31] Three-Station Three-dimensional Bolus-Chase MR Angiography with Real-time Fluoroscopic Tracking
    Johnson, Casey P.
    Weavers, Paul T.
    Borisch, Eric A.
    Grimm, Roger C.
    Hulshizer, Thomas C.
    LaPlante, Christine C.
    Rossman, Phillip J.
    Glockner, James F.
    Young, Phillip M.
    Riederer, Stephen J.
    RADIOLOGY, 2014, 272 (01) : 241 - 251
  • [32] Real-time optical gating for three-dimensional beating heart imaging
    Taylor, Jonathan M.
    Saunter, Christopher D.
    Love, Gordon D.
    Girkin, John M.
    Henderson, Deborah J.
    Chaudhry, Bill
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (11)
  • [33] Real-time, navigator-gated, adaptively corrected 3D coronary MR angiography
    Wang, Y
    Johnston, DL
    Riederer, SJ
    Ehman, RL
    RADIOLOGY, 1996, 201 : 351 - 351
  • [34] Real-time three-dimensional dobutamine stress echocardiography for coronary artery disease diagnosis: validation with coronary angiography
    Aggeli, Constadina
    Giannopoulos, Georgios
    Misovoulos, Platon
    Roussakis, George
    Christoforatou, Euaggelia
    Kokkinakis, Christos
    Brili, Stela
    Stefanadis, Christodoulos
    HEART, 2007, 93 (06) : 672 - 675
  • [35] Three-dimensional coronary MR angiography performed with subject-specific cardiac acquisition windows and motion-adapted respiratory gating
    Plein, S
    Jones, TR
    Ridgway, JP
    Sivananthan, MU
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (02) : 505 - 512
  • [36] Three-dimensional free-breathing pediatric cardiovascular magnetic resonance imaging with real-time navigator respiratory synchronization
    Vick, GW
    Muthupillai, R
    Pignatelli, RH
    Kovalchin, JP
    Chung, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 411A - 411A
  • [37] Coronary magnetic resonance angiography using a free-breathing, T2 weighted, three-dimensional gradient echo sequence with navigator respiratory and ECG gating can be used to detect coronary artery disease
    Moustapha, AI
    Pereyra, M
    Muthupillai, R
    Wilson, JM
    Flamm, SD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 380A - 380A
  • [38] Unroofed coronary sinus on real-time three-dimensional transesophageal echocardiography
    Kam, Kevin Ka-Ho
    Looi, Jen-Li
    Yip, Yu-Yeung
    Lee, Alex Pui-Wai
    Wong, Jeffrey Ka-Tat
    Yu, Cheuk-Man
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 164 (02) : E13 - E14
  • [39] Submillimeter 3D coronary MR angiography with real-time navigator correction in 107 patients with suspected coronary artery disease
    Sommer, T
    Hofer, U
    Hackenbroch, M
    Meyer, C
    Flacke, S
    Schmiedel, A
    Schmitz, C
    Thiemann, K
    Omran, H
    Schild, H
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (04): : 459 - 466
  • [40] Fast Three-Dimensional Noise Reduction for Real-Time Electron Tomography
    Antonio Martinez, Jose
    Jesus Fernandez, Jose
    SOFTWARE TOOLS AND ALGORITHMS FOR BIOLOGICAL SYSTEMS, 2011, 696 : 233 - 242