Navigator-echo-base real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography

被引:304
|
作者
Wang, Y [1 ]
Rossman, PJ [1 ]
Grimm, RC [1 ]
Riederer, SJ [1 ]
Ehman, RL [1 ]
机构
[1] MAYO CLIN & MAYO FDN, DEPT DIAGNOST RADIOL, ROCHESTER, MN 55905 USA
关键词
coronary vessels; MR; magnetic resonance (MR); artifact; motion correction; vascular studies;
D O I
10.1148/radiology.198.1.8539406
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To test the hypothesis that respiration effects in three-dimensional (3D) coronary magnetic resonance (MR) imaging can be reduced with navigator-echo-based gating or triggering according to the superior-inferior position of the diaphragm. MATERIALS AND METHODS: Realtime respiratory gating and respiratory triggering (breath hold with feedback) were implemented with navigator echoes in a magnetization-prepared, segmented, 3D coronary imaging sequence. The two techniques were first tested with a motion phantom. An imaging protocol that compared real-time respiratory-gated acquisition, real-time respiratory-triggered acquisition, and continuous acquisition was then evaluated in six healthy subjects. RESULTS: Real-time respiratory-gated and respiratory-triggered acquisition were superior to continuous acquisition with two signals averaged (P = .025). The performance of the gated acquisition was about the same as that of the triggered acquisition (P = .05). CONCLUSION: Navigator-echo-based, real-time respiratory-gating and respiratory-triggering techniques are practical methods for effective reduction of respiration effects in coronary MR imaging.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 50 条
  • [21] Magnetic resonance coronary angiography using navigator echo gated real-time slice following
    John N. Oshinski
    W. Thomas Dixon
    Roderic I. Pettitgrew
    The International Journal of Cardiac Imaging, 1998, 14 : 191 - 199
  • [22] Magnetic resonance coronary angiography using navigator echo gated real-time slice following
    Oshinski, JN
    Hofland, L
    Dixon, WT
    Pettigrew, RI
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1998, 14 (03): : 191 - 199
  • [23] Prospective navigator-echo-based real-time triggering of fetal head movement for the reduction of artifacts
    H. Bonel
    K. A. Frei
    L. Raio
    M. Meyer-Wittkopf
    L. Remonda
    R. Wiest
    European Radiology, 2008, 18
  • [24] Prospective navigator-echo-based real-time triggering of fetal head movement for the reduction of artifacts
    Bonel, H.
    Frei, K. A.
    Raio, L.
    Meyer-Wittkopf, M.
    Remonda, L.
    Wiest, R.
    EUROPEAN RADIOLOGY, 2008, 18 (04) : 822 - 829
  • [25] Comparison of two-dimensional breath-hold coronary MR angiography, three-dimensional coronary MR angiography in navigator technique, and conventional coronary angiography in patients with coronary artery disease
    Lentschig, MG
    Hoeffgen, M
    Wichter, T
    Reimer, P
    Rummeny, EJ
    RADIOLOGY, 1998, 209P : 305 - 305
  • [26] Three-dimensional respiratory-gated MR angiography of coronary arteries: Comparison with conventional coronary angiography
    Post, JC
    vanRossum, AC
    Hofman, MBM
    Valk, J
    Visser, CA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (06) : 1399 - 1404
  • [27] Three-dimensional MR coronary angiography with the navigator technique for primary diagnosis of coronary artery disease: Comparison with conventional coronary angiography.
    Sandstede, J
    Pabst, T
    Kenn, W
    Beer, M
    Neubauer, S
    Hahn, D
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (03): : 269 - 274
  • [28] Three-dimensional respiratory-gated coronary MR angiography with reference to X-ray coronary angiography
    Ikonen, AEJ
    Manninen, HI
    Vainio, P
    Hirvonen, TPJ
    Vanninen, RL
    Matsi, PJ
    Soimakallio, S
    Hartikainen, JEK
    ACTA RADIOLOGICA, 2003, 44 (06) : 583 - 589
  • [29] Detection of coronary stenoses on source and projection images using three-dimensional MR angiography with retrospective respiratory gating: Preliminary experience
    Woodard, PK
    Li, D
    Haacke, EM
    Dhawale, PJ
    Kaushikkar, S
    Barzilai, B
    Braverman, AC
    Ludbrook, PA
    Weiss, AN
    Brown, JJ
    Mirowitz, SA
    Pilgram, TK
    Gutierrez, FR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (04) : 883 - 888
  • [30] Three-dimensional contrast-enhanced MR angiography with real-time fluoroscopic triggering: Design specifications and technical reliability in 330 patient studies
    Riederer, SJ
    Bernstein, MA
    Breen, JF
    Busse, RF
    Ehman, RL
    Fain, SB
    Hulshizer, TC
    Huston, J
    King, BF
    Kruger, DG
    Rossman, PJ
    Shah, S
    RADIOLOGY, 2000, 215 (02) : 584 - 593