Lorentz Force Electrical-Impedance Tomography Using Linearly Frequency-Modulated Ultrasound Pulse

被引:32
|
作者
Sun, Zhishen [1 ,2 ,3 ]
Liu, Guoqiang [1 ,2 ]
Xia, Hui [1 ]
Catheline, Stefan [3 ]
机构
[1] Chinese Acad Sci, Inst Elect Engn, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Univ Claude Bernard Lyon 1, INSERM, Ctr Leon Berard, LabTAU UMR1032, F-69003 Lyon, France
基金
中国国家自然科学基金;
关键词
Hall effect imaging; linearly frequency-modulated (LFM) ultrasound; Lorentz force electrical-impedance tomography (LFEIT); magneto-acousto-electrical tomography (MAET); RANGE MEASUREMENT;
D O I
10.1109/TUFFC.2017.2781189
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Lorentz force electrical-impedance tomography (LFEIT) combines ultrasound stimulation and electromagnetic field detection with the goal of creating a high-contrast and high-resolution hybrid imaging modality. To reduce the peak stimulation power to the ultrasound transducer in LFEIT, linearly frequency-modulated (LFM) ultrasound pulse was investigated in this paper. First, the coherency between LFM ultrasound excitation and the resulting local current density was established theoretically. Then, experiments were done using different agar phantoms of conductivity ranging from 0.2 to 0.5 S/m. The results showed: 1) using electrical signal of peak instantaneous power of 39.54 dBm to the ultrasound transducer, which was 25.5 dB lower than the peak instantaneous power of the high-voltage narrow pulse adopted in traditional LFEIT (65.05 dBm), the LFM ultrasound pulse-based LFEIT can detect the electrical conductivity discontinuity positions precisely; 2) the reconstructed B-scan image of the electrical conductivity discontinuity distribution is comparable to that obtained through LFEIT with high-voltage narrow pulse; and 3) axial resolution of 1 mm was achieved with the experimental setup. The method of LFM ultrasound pulse stimulation and coherent detection initiates an alternative scheme toward the clinical application of LFEIT.
引用
收藏
页码:168 / 177
页数:10
相关论文
共 50 条
  • [21] Acousto-Electrical Speckle Pattern in Lorentz Force Electrical Impedance Tomography
    Grasland-Mongrain, Pol
    Destrempes, Francois
    Mari, Jean-Martial
    Souchon, Remi
    Catheline, Stefan
    Chapelon, Jean-Yves
    Lafon, Cyril
    Cloutier, Guy
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 221 - 223
  • [22] Acousto-electrical speckle pattern in Lorentz force electrical impedance tomography
    Grasland-Mongrain, Pol
    Destrempes, Francois
    Mari, Jean-Martial
    Souchon, Remi
    Catheline, Stefan
    Chapelon, Jean-Yves
    Lafon, Cyril
    Cloutier, Guy
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (09): : 3747 - 3757
  • [23] Broadband and High-Precision Instantaneous Frequency Measurement Using Linearly Frequency-Modulated Waveform and Pulse Compression Processing
    Zhu, Beibei
    Xue, Min
    Yu, Changyuan
    Pan, Shilong
    2019 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE (ACP), 2019,
  • [24] BLOOD-FLOW IMAGING USING ELECTRICAL-IMPEDANCE TOMOGRAPHY
    BROWN, BH
    LEATHARD, A
    SINTON, A
    MCARDLE, FJ
    SMITH, RWM
    BARBER, DC
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 175 - 179
  • [25] Design and simulation of superconducting Lorentz Force Electrical Impedance Tomography (LFEIT)
    Shen, Boyang
    Fu, Lin
    Geng, Jianzhao
    Zhang, Xiuchang
    Zhang, Heng
    Dong, Qihuan
    Li, Chao
    Li, Jing
    Coombs, T. A.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2016, 524 : 5 - 12
  • [26] PRACTICAL FACTORS IN NEONATAL LUNG IMAGING USING ELECTRICAL-IMPEDANCE TOMOGRAPHY
    TAKTAK, A
    RECORD, P
    GADD, R
    ROLFE, P
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (02) : 202 - 205
  • [27] USING THE HILBERT UNIQUENESS METHOD IN A RECONSTRUCTION ALGORITHM FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    DAI, WW
    MARSILI, PM
    MARTINEZ, E
    MORUCCI, JP
    PHYSIOLOGICAL MEASUREMENT, 1994, 15 : A161 - A168
  • [28] DETECTING ESOPHAGEAL-RELATED CHANGES USING ELECTRICAL-IMPEDANCE TOMOGRAPHY
    EROL, RA
    SMALLWOOD, RH
    BROWN, BH
    CHERIAN, P
    BARDHAN, KD
    PHYSIOLOGICAL MEASUREMENT, 1995, 16 : A143 - A152
  • [29] AN EXPERIMENTAL-STUDY IN ELECTRICAL-IMPEDANCE TOMOGRAPHY USING BACKPROJECTION RECONSTRUCTION
    GUARDO, R
    BOULAY, C
    MURRAY, B
    BERTRAND, M
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (07) : 617 - 627
  • [30] DETECTION OF CHANGES IN INTRATHORACIC FLUID IN MAN USING ELECTRICAL-IMPEDANCE TOMOGRAPHY
    CAMPBELL, JH
    HARRIS, ND
    ZHANG, F
    MORICE, AH
    BROWN, BH
    CLINICAL SCIENCE, 1994, 87 (01) : 97 - 101