Lorentz Force Electrical-Impedance Tomography Using Linearly Frequency-Modulated Ultrasound Pulse

被引:32
|
作者
Sun, Zhishen [1 ,2 ,3 ]
Liu, Guoqiang [1 ,2 ]
Xia, Hui [1 ]
Catheline, Stefan [3 ]
机构
[1] Chinese Acad Sci, Inst Elect Engn, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Univ Claude Bernard Lyon 1, INSERM, Ctr Leon Berard, LabTAU UMR1032, F-69003 Lyon, France
基金
中国国家自然科学基金;
关键词
Hall effect imaging; linearly frequency-modulated (LFM) ultrasound; Lorentz force electrical-impedance tomography (LFEIT); magneto-acousto-electrical tomography (MAET); RANGE MEASUREMENT;
D O I
10.1109/TUFFC.2017.2781189
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Lorentz force electrical-impedance tomography (LFEIT) combines ultrasound stimulation and electromagnetic field detection with the goal of creating a high-contrast and high-resolution hybrid imaging modality. To reduce the peak stimulation power to the ultrasound transducer in LFEIT, linearly frequency-modulated (LFM) ultrasound pulse was investigated in this paper. First, the coherency between LFM ultrasound excitation and the resulting local current density was established theoretically. Then, experiments were done using different agar phantoms of conductivity ranging from 0.2 to 0.5 S/m. The results showed: 1) using electrical signal of peak instantaneous power of 39.54 dBm to the ultrasound transducer, which was 25.5 dB lower than the peak instantaneous power of the high-voltage narrow pulse adopted in traditional LFEIT (65.05 dBm), the LFM ultrasound pulse-based LFEIT can detect the electrical conductivity discontinuity positions precisely; 2) the reconstructed B-scan image of the electrical conductivity discontinuity distribution is comparable to that obtained through LFEIT with high-voltage narrow pulse; and 3) axial resolution of 1 mm was achieved with the experimental setup. The method of LFM ultrasound pulse stimulation and coherent detection initiates an alternative scheme toward the clinical application of LFEIT.
引用
收藏
页码:168 / 177
页数:10
相关论文
共 50 条
  • [11] Lorentz Force Electrical Impedance Detection Using Step Frequency Technique
    Sun, Zhi-Shen
    Liu, Guo-Qiang
    Xia, Hui
    CHINESE PHYSICS LETTERS, 2018, 35 (01)
  • [12] Lorentz Force Electrical Impedance Detection Using Step Frequency Technique
    孙直申
    刘国强
    夏慧
    Chinese Physics Letters, 2018, 35 (01) : 54 - 58
  • [13] Lorentz Force Electrical Impedance Detection Using Step Frequency Technique
    孙直申
    刘国强
    夏慧
    Chinese Physics Letters, 2018, (01) : 54 - 58
  • [14] DUAL-FREQUENCY ELECTRICAL-IMPEDANCE TOMOGRAPHY INVITRO AND INVIVO
    GRIFFITHS, H
    ZHANG, Z
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 476 - 477
  • [15] ELECTRICAL-IMPEDANCE TOMOGRAPHY USING INDUCED AND INJECTED CURRENTS
    GENCER, NG
    IDER, YZ
    KUZUOGLU, M
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 95 - 99
  • [16] MEASURING LUNG RESISTIVITY USING ELECTRICAL-IMPEDANCE TOMOGRAPHY
    WOO, EJ
    HUA, P
    WEBSTER, JG
    TOMPKINS, WJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (07) : 756 - 760
  • [17] IDENTIFYING ESOPHAGEAL CONTENTS USING ELECTRICAL-IMPEDANCE TOMOGRAPHY
    EROL, RA
    MANGNALL, Y
    LEATHARD, AD
    SMALLWOOD, RH
    BROWN, BH
    CHERIAN, P
    BARDHAN, KD
    PHYSIOLOGICAL MEASUREMENT, 1995, 16 (04) : 253 - 261
  • [18] Design of a Superconducting Magnet for Lorentz Force Electrical Impedance Tomography
    Shen, Boyang
    Fu, Lin
    Geng, Jianzhao
    Zhang, Heng
    Zhang, Xiuchang
    Zhong, Zhaoyang
    Huang, Zhen
    Coombs, T. A.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (03)
  • [19] Frequency-Modulated Lorentz Force Magnetometer With Enhanced Sensitivity via Mechanical Amplification
    Li, Mo
    Nitzan, Sarah
    Horsley, David A.
    IEEE ELECTRON DEVICE LETTERS, 2015, 36 (01) : 62 - 64
  • [20] Sensitivity Matrix for Ultrasound Modulated Electrical Impedance Tomography
    Song, Xizi
    Xu, Yanbin
    Dong, Feng
    2016 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, 2016, : 585 - 590