Lorentz Force Electrical-Impedance Tomography Using Linearly Frequency-Modulated Ultrasound Pulse

被引:32
|
作者
Sun, Zhishen [1 ,2 ,3 ]
Liu, Guoqiang [1 ,2 ]
Xia, Hui [1 ]
Catheline, Stefan [3 ]
机构
[1] Chinese Acad Sci, Inst Elect Engn, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Univ Claude Bernard Lyon 1, INSERM, Ctr Leon Berard, LabTAU UMR1032, F-69003 Lyon, France
基金
中国国家自然科学基金;
关键词
Hall effect imaging; linearly frequency-modulated (LFM) ultrasound; Lorentz force electrical-impedance tomography (LFEIT); magneto-acousto-electrical tomography (MAET); RANGE MEASUREMENT;
D O I
10.1109/TUFFC.2017.2781189
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Lorentz force electrical-impedance tomography (LFEIT) combines ultrasound stimulation and electromagnetic field detection with the goal of creating a high-contrast and high-resolution hybrid imaging modality. To reduce the peak stimulation power to the ultrasound transducer in LFEIT, linearly frequency-modulated (LFM) ultrasound pulse was investigated in this paper. First, the coherency between LFM ultrasound excitation and the resulting local current density was established theoretically. Then, experiments were done using different agar phantoms of conductivity ranging from 0.2 to 0.5 S/m. The results showed: 1) using electrical signal of peak instantaneous power of 39.54 dBm to the ultrasound transducer, which was 25.5 dB lower than the peak instantaneous power of the high-voltage narrow pulse adopted in traditional LFEIT (65.05 dBm), the LFM ultrasound pulse-based LFEIT can detect the electrical conductivity discontinuity positions precisely; 2) the reconstructed B-scan image of the electrical conductivity discontinuity distribution is comparable to that obtained through LFEIT with high-voltage narrow pulse; and 3) axial resolution of 1 mm was achieved with the experimental setup. The method of LFM ultrasound pulse stimulation and coherent detection initiates an alternative scheme toward the clinical application of LFEIT.
引用
收藏
页码:168 / 177
页数:10
相关论文
共 50 条
  • [31] Finite element modelling and image reconstruction for Lorentz force electrical impedance tomography
    Polydorides, Nick
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (04)
  • [32] Ultrasound Modulated Electrical Impedance Tomography by Contrast Libraries of Measurements Variation
    Zhang, Shengnan
    Xu, Yanbin
    Dong, Feng
    2017 29TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2017, : 1027 - 1032
  • [33] A MODEL STUDY OF ELECTRICAL-IMPEDANCE TOMOGRAPHY USING SYNTHETIC FINITE PRECISION DATA
    BUCHERT, R
    SCHILCHER, K
    ZEITSCHRIFT FUR NATURFORSCHUNG SECTION A-A JOURNAL OF PHYSICAL SCIENCES, 1994, 49 (10): : 920 - 926
  • [35] NOISE IMMUNITY OF A DIGITAL DATA TRANSMISSION SYSTEM USING LINEARLY FREQUENCY-MODULATED SIGNALS
    ZAYTSEV, DL
    ZHURAVLE.VI
    TELECOMMUNICATIONS AND RADIO ENGINEER-USSR, 1968, (04): : 13 - &
  • [36] Measurement of distance and medium velocity using frequency-modulated sound/ultrasound
    Sahu, O. P.
    Gupta, Anil K.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (04) : 838 - 842
  • [37] NEW METHOD FOR ULTRASOUND CONTRAST IMAGING USING FREQUENCY-MODULATED TRANSMISSION
    Ohuchi, H.
    Kamiyama, N.
    Kawagishi, T.
    Imamura, T.
    Asanuma, T.
    Ishikura, H.
    Beppu, S.
    ACOUSTICAL IMAGING, VOL 29, 2008, 29 : 121 - +
  • [38] A mathematical and numerical framework for ultrasonically-induced Lorentz force electrical impedance tomography
    Ammari, Habib
    Grasland-Mongrain, Pol
    Millen, Pierre
    Seppecher, Laurent
    Seo, Jin-Keun
    JOURNAL DE MATHEMATIQUES PURES ET APPLIQUEES, 2015, 103 (06): : 1390 - 1409
  • [39] Optical pulse compression reflectometry based on single-sideband modulator driven by electrical frequency-modulated pulse
    Zou, Weiwen
    Yu, Lei
    Yang, Shuo
    Chen, Jianping
    OPTICS COMMUNICATIONS, 2016, 367 : 155 - 160
  • [40] ITERATIVE RECONSTRUCTION METHODS USING REGULARIZATION AND OPTIMAL CURRENT PATTERNS IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    HUA, P
    WOO, EJ
    WEBSTER, JG
    TOMPKINS, WJ
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (04) : 621 - 628