DETECTING ESOPHAGEAL-RELATED CHANGES USING ELECTRICAL-IMPEDANCE TOMOGRAPHY

被引:4
|
作者
EROL, RA [1 ]
SMALLWOOD, RH [1 ]
BROWN, BH [1 ]
CHERIAN, P [1 ]
BARDHAN, KD [1 ]
机构
[1] ROTHERHAM DIST GEN HOSP,ROTHERHAM,S YORKSHIRE,ENGLAND
关键词
D O I
10.1088/0967-3334/16/3A/014
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Preliminary work has been carried out using the Sheffield mark II real time Err system, looking for changes in conductivity which occur in the stomach and oesophagus following a swallow of a small volume of either a conducting or a non-conducting liquid. This has been done using three different configurations: a conventional transverse array placed around the thorax, a rosette array on the abdomen, and a rosette array placed on the back. Results show a significant difference between the two liquids, which can be detected equally well by the three electrode configurations.
引用
收藏
页码:A143 / A152
页数:10
相关论文
共 50 条
  • [1] IDENTIFYING ESOPHAGEAL CONTENTS USING ELECTRICAL-IMPEDANCE TOMOGRAPHY
    EROL, RA
    MANGNALL, Y
    LEATHARD, AD
    SMALLWOOD, RH
    BROWN, BH
    CHERIAN, P
    BARDHAN, KD
    PHYSIOLOGICAL MEASUREMENT, 1995, 16 (04) : 253 - 261
  • [2] ELECTRICAL-IMPEDANCE TOMOGRAPHY
    不详
    SEMAINE DES HOPITAUX, 1993, 69 (28): : 855 - 855
  • [3] DETECTION OF CHANGES IN INTRATHORACIC FLUID IN MAN USING ELECTRICAL-IMPEDANCE TOMOGRAPHY
    CAMPBELL, JH
    HARRIS, ND
    ZHANG, F
    MORICE, AH
    BROWN, BH
    CLINICAL SCIENCE, 1994, 87 (01) : 97 - 101
  • [4] ELECTRICAL-IMPEDANCE TOMOGRAPHY USING INDUCED CURRENTS
    GENCER, NG
    KUZUOGLU, M
    IDER, YZ
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (02) : 338 - 350
  • [5] USING COMPOUND ELECTRODES IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    HUA, P
    WOO, EJ
    WEBSTER, JG
    TOMPKINS, WJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (01) : 29 - 34
  • [6] ELECTRICAL-IMPEDANCE TOMOGRAPHY - PREFACE
    BARBER, DC
    BROWN, BH
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 3 - 4
  • [7] ELECTRICAL-IMPEDANCE TOMOGRAPHY - PREFACE
    BARBER, DC
    BROWN, BH
    PHYSIOLOGICAL MEASUREMENT, 1995, 16 : U3 - U3
  • [8] ELECTRICAL-IMPEDANCE TOMOGRAPHY - PREFACE
    BARBER, DC
    BROWN, BH
    PHYSIOLOGICAL MEASUREMENT, 1994, 15 : UA1 - UA1
  • [9] MULTIFREQUENCY ELECTRICAL-IMPEDANCE TOMOGRAPHY
    RECORD, PM
    GADD, R
    VINTHER, F
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 67 - 72
  • [10] ELECTRICAL-IMPEDANCE TOMOGRAPHY - THE CONSTRUCTION AND APPLICATION TO PHYSIOLOGICAL MEASUREMENT OF ELECTRICAL-IMPEDANCE IMAGES
    BROWN, BH
    BARBER, DC