DETECTING ESOPHAGEAL-RELATED CHANGES USING ELECTRICAL-IMPEDANCE TOMOGRAPHY

被引:4
|
作者
EROL, RA [1 ]
SMALLWOOD, RH [1 ]
BROWN, BH [1 ]
CHERIAN, P [1 ]
BARDHAN, KD [1 ]
机构
[1] ROTHERHAM DIST GEN HOSP,ROTHERHAM,S YORKSHIRE,ENGLAND
关键词
D O I
10.1088/0967-3334/16/3A/014
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Preliminary work has been carried out using the Sheffield mark II real time Err system, looking for changes in conductivity which occur in the stomach and oesophagus following a swallow of a small volume of either a conducting or a non-conducting liquid. This has been done using three different configurations: a conventional transverse array placed around the thorax, a rosette array on the abdomen, and a rosette array placed on the back. Results show a significant difference between the two liquids, which can be detected equally well by the three electrode configurations.
引用
收藏
页码:A143 / A152
页数:10
相关论文
共 50 条
  • [41] COMMON-MODE FEEDBACK IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    ROSELL, J
    RIU, P
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 11 - 14
  • [42] THE SPECTRAL EXPANSION OF A HEAD MODEL IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    ZADEHKOOCHAK, M
    BLOTT, BH
    HAMES, TK
    GEORGE, RF
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1991, 12 : 101 - 105
  • [43] NEURAL NETWORKS FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY IMAGE CHARACTERIZATION
    MILLER, AS
    BLOTT, BH
    HAMES, TK
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 119 - 123
  • [44] ELECTRICAL-IMPEDANCE TOMOGRAPHY SYSTEMS BASED ON VOLTAGE DRIVE
    SANSEN, W
    GEERAERTS, B
    VANPETEGEM, W
    STEYAERT, M
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 39 - 42
  • [45] FINITE-ELEMENT METHOD IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    WOO, EJ
    HUA, P
    WEBSTER, JG
    TOMPKINS, WJ
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1994, 32 (05) : 530 - 536
  • [46] RAW DATA INTERCHANGE FORMAT FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    RECORD, PM
    COSTA, PJR
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 201 - 207
  • [47] PERFORMANCE OF A DIFFERENTIAL SYNCHRONOUS DEMODULATOR FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    KOUKOURLIS, CS
    TRIGONIDIS, VK
    KYRIAKOU, GA
    SAHALOS, JN
    BATAS, K
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 35 - 38
  • [48] COMMENT ON THE ALTERNATIVE RECONSTRUCTION ALGORITHM FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    KOTRE, CJ
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1989, 10 (04): : 370 - 371
  • [49] AN IMAGE-ENHANCEMENT TECHNIQUE FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    DOBSON, DC
    SANTOSA, F
    INVERSE PROBLEMS, 1994, 10 (02) : 317 - 334
  • [50] A MODEL STUDY OF ELECTRICAL-IMPEDANCE TOMOGRAPHY USING SYNTHETIC FINITE PRECISION DATA
    BUCHERT, R
    SCHILCHER, K
    ZEITSCHRIFT FUR NATURFORSCHUNG SECTION A-A JOURNAL OF PHYSICAL SCIENCES, 1994, 49 (10): : 920 - 926