A comparison of 3 hand-held dynamometers used to measure hip abduction strength

被引:5
|
作者
Fenter, PC [1 ]
Bellew, JW [1 ]
Pitts, T [1 ]
Kay, R [1 ]
机构
[1] Louisiana State Univ, Hlth Sci Ctr, Dept Phys Therapy, Shreveport, LA 71130 USA
关键词
measurement; objective; hip muscle; pelvic strength; dynamometry;
D O I
10.1519/00124278-200308000-00018
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Quantification of strength with hand-held dynamometers is commonplace. Hand-held dynamometers offer ease of use; however, previous investigations have shown much variability between repeated measures using the same dynamometer. Even less is known regarding the degree of variability between various dynamometers. Therefore, the intent of this investigation was to compare measures of hip abduction strength recorded with 3 different but commonly used hand-held dynamometers, specifically the Microfet 2 Load Cell, Jamar Hand-Held, and Dial Push-Pull Gauge. Maximal isometric hip abduction strength was recorded in 10 women (27.6 +/- 6.2 years) over 3 consecutive days using a different device each day. A significant difference in recorded force was noted between the devices (p < 0.001) as the Microfet showed significantly less force than the others. This was supported by intraclass correlation coefficients (ICCs) ranging from 0.277 to 0.688. These data suggest that consideration must be given to using the same dynamometer when quantifying strength over repeated sessions.
引用
收藏
页码:531 / 535
页数:5
相关论文
共 50 条
  • [1] Reliability of measurements of hip abduction strength obtained with a hand-held dynamometer
    Ieiri, Akira
    Tushima, Eiki
    Ishida, Kazuhiro
    Inoue, Masahiro
    Kanno, Taiki
    Masuda, Takeshi
    [J]. PHYSIOTHERAPY THEORY AND PRACTICE, 2015, 31 (02) : 146 - 152
  • [2] Variability between Different Hand-Held Dynamometers for Measuring Muscle Strength
    Du, William
    Cornett, Kayla M. D.
    Donlevy, Gabrielle A.
    Burns, Joshua
    Mckay, Marnee J.
    [J]. SENSORS, 2024, 24 (06)
  • [3] HAND-HELD DEVICE TO MEASURE FINGER (THUMB) STRENGTH
    KROEMER, KHE
    GIENAPP, EM
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1970, 29 (04) : 526 - &
  • [4] Clinical assessment of hip strength using a hand-held dynamometer is reliable
    Thorborg, K.
    Petersen, J.
    Magnusson, S. P.
    Holmich, P.
    [J]. SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2010, 20 (03) : 493 - 501
  • [5] Reliability of a Trunk Flexion and Extensor Muscle Strength Test with Hand-Held and Isokinetic Dynamometers in Female Athletes
    Juan-Recio, Casto
    Prat-Luri, Amaya
    Barbado, David
    Vera-Garcia, Francisco J.
    Moreno-Perez, Victor
    [J]. JOURNAL OF HUMAN KINETICS, 2024, 92 : 43 - 52
  • [6] Reliability and Validity of the Hand-Held Dynamometer in Measuring Hip External Rotation Strength
    Quinlevan, Megan
    Boland, Samantha
    Dodge, Erica
    Gribble, Phillip
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 196 - 196
  • [7] Hip extension strength measured using hand-held dynamometry in a rehabilitation setting
    Cardin, Grace
    Bohannon, Richard W.
    [J]. ISOKINETICS AND EXERCISE SCIENCE, 2017, 25 (02) : 157 - 160
  • [8] Influence of lever arm and stabilization on measures of hip abduction and adduction torque obtained by hand-held dynamometry
    Krause, David A.
    Schlagel, Susan J.
    Stember, Beth M.
    Zoetewey, Janice E.
    Hollman, John H.
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2007, 88 (01): : 37 - 42
  • [9] Normative values for isometric muscle force measurements obtained with hand-held dynamometers
    Andrews, AW
    Thomas, MW
    Bohannon, RW
    [J]. PHYSICAL THERAPY, 1996, 76 (03): : 248 - 259
  • [10] COMPARISON OF METHODS FOR EVALUATING UPPER LIMB STRENGTH BY HAND-HELD DYNAMOMETRY
    Ventura Nepomuceno Junior, Balbino Rivail
    dos Santos Menezes, Manoela Porto
    Bastos dos Santos, Kamilla Ribeiro
    Gomes Neto, Mansueto
    [J]. REVISTA BRASILEIRA DE MEDICINA DO ESPORTE, 2021, 27 (01) : 42 - 48