A comparison of 3 hand-held dynamometers used to measure hip abduction strength

被引:5
|
作者
Fenter, PC [1 ]
Bellew, JW [1 ]
Pitts, T [1 ]
Kay, R [1 ]
机构
[1] Louisiana State Univ, Hlth Sci Ctr, Dept Phys Therapy, Shreveport, LA 71130 USA
关键词
measurement; objective; hip muscle; pelvic strength; dynamometry;
D O I
10.1519/00124278-200308000-00018
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Quantification of strength with hand-held dynamometers is commonplace. Hand-held dynamometers offer ease of use; however, previous investigations have shown much variability between repeated measures using the same dynamometer. Even less is known regarding the degree of variability between various dynamometers. Therefore, the intent of this investigation was to compare measures of hip abduction strength recorded with 3 different but commonly used hand-held dynamometers, specifically the Microfet 2 Load Cell, Jamar Hand-Held, and Dial Push-Pull Gauge. Maximal isometric hip abduction strength was recorded in 10 women (27.6 +/- 6.2 years) over 3 consecutive days using a different device each day. A significant difference in recorded force was noted between the devices (p < 0.001) as the Microfet showed significantly less force than the others. This was supported by intraclass correlation coefficients (ICCs) ranging from 0.277 to 0.688. These data suggest that consideration must be given to using the same dynamometer when quantifying strength over repeated sessions.
引用
收藏
页码:531 / 535
页数:5
相关论文
共 50 条
  • [41] Keratometry in dogs: Comparison of two automatic hand-held keratometers
    Gorig, C
    Meyer-Lindenberg, A
    Ulrich, S
    Wagner, F
    Nolte, I
    [J]. TIERARZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 1997, 25 (06): : 659 - 665
  • [42] HAND-HELD DYNAMOMETRY - STABILITY OF MUSCLE STRENGTH OVER MULTIPLE MEASUREMENTS
    BOHANNON, RW
    [J]. CLINICAL BIOMECHANICS, 1987, 2 (02) : 74 - 77
  • [43] HAND-HELD DYNAMOMETRY: TESTER STRENGTH IS PARAMOUNT, EVEN IN FRAIL POPULATIONS
    Stone, Carol A.
    Nolan, Brid
    Lawlor, Peter G.
    Kenny, Rose Anne
    [J]. JOURNAL OF REHABILITATION MEDICINE, 2011, 43 (09) : 808 - 811
  • [44] Hand-held dynamometry for muscle strength measurement in children with cerebral palsy
    Crompton, Jodi
    Galea, Mary P.
    Phillips, Bev
    [J]. DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 2007, 49 (02): : 106 - 111
  • [45] Hand-held dynamometry for assessment of muscle strength in patients with inflammatory myopathies
    Saygin, Didem
    Oddis, Chester V.
    Moghadam-Kia, Siamak
    Rockette-Wagner, Bonny
    Neiman, Nicole
    Koontz, Diane
    Aggarwal, Rohit
    [J]. RHEUMATOLOGY, 2021, 60 (05) : 2146 - 2156
  • [46] A DIGITAL HAND-HELD METER FOR RF FIELD-STRENGTH TESTING
    不详
    [J]. MICROWAVE JOURNAL, 1994, 37 (12) : 92 - &
  • [47] A COMPARISON OF SLIT LAMP SUPPORTED VERSUS HAND-HELD BIOMETRY
    HEYWORTH, PL
    TABANDEH, H
    PATEL, CK
    TEIMORY, M
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1963 - 1963
  • [48] Knee and hip strength measurements obtained by a hand-held dynamometer stabilized by a belt and an examiner demonstrate parallel reliability but not agreement
    Florencio, Lidiane L.
    Martins, Jaqueline
    da Silva, Marcelo R. B.
    da Silva, Janaina R.
    Bellizzi, Gustavo L.
    Bevilaqua-Grossi, Debora
    [J]. PHYSICAL THERAPY IN SPORT, 2019, 38 : 115 - 122
  • [49] The use of a hand-held algometer as a method to measure mechanical nociceptive thresholds in sheep
    Stubsjoen, S. M.
    Valle, P. S.
    Zanella, A. J.
    [J]. ANIMAL WELFARE, 2010, 19 (01) : 31 - 36
  • [50] GRIP-STRENGTH MEASUREMENT - A COMPARISON OF 3 JAMAR DYNAMOMETERS
    FLOODJOY, M
    MATHIOWETZ, V
    [J]. OCCUPATIONAL THERAPY JOURNAL OF RESEARCH, 1987, 7 (04): : 235 - 243