A comparison of 3 hand-held dynamometers used to measure hip abduction strength

被引:5
|
作者
Fenter, PC [1 ]
Bellew, JW [1 ]
Pitts, T [1 ]
Kay, R [1 ]
机构
[1] Louisiana State Univ, Hlth Sci Ctr, Dept Phys Therapy, Shreveport, LA 71130 USA
关键词
measurement; objective; hip muscle; pelvic strength; dynamometry;
D O I
10.1519/00124278-200308000-00018
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Quantification of strength with hand-held dynamometers is commonplace. Hand-held dynamometers offer ease of use; however, previous investigations have shown much variability between repeated measures using the same dynamometer. Even less is known regarding the degree of variability between various dynamometers. Therefore, the intent of this investigation was to compare measures of hip abduction strength recorded with 3 different but commonly used hand-held dynamometers, specifically the Microfet 2 Load Cell, Jamar Hand-Held, and Dial Push-Pull Gauge. Maximal isometric hip abduction strength was recorded in 10 women (27.6 +/- 6.2 years) over 3 consecutive days using a different device each day. A significant difference in recorded force was noted between the devices (p < 0.001) as the Microfet showed significantly less force than the others. This was supported by intraclass correlation coefficients (ICCs) ranging from 0.277 to 0.688. These data suggest that consideration must be given to using the same dynamometer when quantifying strength over repeated sessions.
引用
收藏
页码:531 / 535
页数:5
相关论文
共 50 条
  • [31] USING A HAND-HELD CALCULATOR FOR SHIPS POSITION COMPARISON
    MEADEN, TR
    [J]. JOURNAL OF NAVIGATION, 1976, 29 (03): : 296 - 298
  • [32] Comparison of Hand-held WEMI Target Detection Algorithms
    McCurley, Connor H.
    Bocinsky, James
    Zare, Alina
    [J]. DETECTION AND SENSING OF MINES, EXPLOSIVE OBJECTS, AND OBSCURED TARGETS XXIV, 2019, 11012
  • [33] COMPARISON OF HAND-HELD COMPUTERS FOR NUTRITION ASSESSMENT AND SUPPORT
    ORTA, J
    REINARTS, CL
    [J]. JOURNAL OF THE AMERICAN DIETETIC ASSOCIATION, 1994, 94 (12) : 1409 - 1414
  • [35] CONTROLLING SNOW SURFACE STRENGTH MEASUREMENTS WITH A HAND-HELD CALCULATOR
    MARTINELLI, M
    OZMENT, A
    [J]. COLD REGIONS SCIENCE AND TECHNOLOGY, 1984, 9 (03) : 277 - 281
  • [36] A new hand-held indirect calorimeter to measure postprandial energy expenditure
    St-Onge, MP
    Rubiano, F
    Jones, A
    Heymsfield, SB
    [J]. OBESITY RESEARCH, 2004, 12 (04): : 704 - 709
  • [37] Intrarater and interrater reliability of a hand-held dynamometric technique to quantify palmar thumb abduction strength in individuals with and without carpal tunnel syndrome
    Mathews, Harvey
    Middleton, Addie
    Boan, Lindsey
    Jacks, Madison
    Riddick, Lindsey
    Shepherd, Jessica
    Patel, Jay
    McNeal, Antonia
    Fritz, Stacy
    [J]. JOURNAL OF HAND THERAPY, 2018, 31 (04) : 554 - 561
  • [38] An evaluation of the Hand-held Electronic Dictionaries Used by Chinese EFL Learners
    Chen, Meilin
    [J]. PACLIC 20: Proceedings of the 20th Pacific Asia Conference on Language, Information and Computation, 2006, : 463 - 466
  • [39] HAND-HELD CT STEREOTAXIC GUIDANCE-SYSTEM - COMPARISON WITH HAND GUIDANCE
    SHANG, Y
    ONIK, G
    THAETE, L
    CAMPBELL, W
    PORTERFIELD, B
    [J]. RADIOLOGY, 1990, 174 (03) : 1066 - 1066
  • [40] Keratometry in dogs: Comparison of two automatic hand-held keratometers
    Gorig, C
    Meyer-Lindenberg, A
    Ulrich, S
    Wagner, F
    Nolte, I
    [J]. TIERARZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 1997, 25 (06): : 659 - 665