Variability between Different Hand-Held Dynamometers for Measuring Muscle Strength

被引:1
|
作者
Du, William [1 ]
Cornett, Kayla M. D. [1 ,2 ]
Donlevy, Gabrielle A. [1 ,2 ]
Burns, Joshua [1 ,2 ]
Mckay, Marnee J. [1 ]
机构
[1] Univ Sydney, Fac Med & Hlth, Sydney Sch Hlth Sci, Sydney, NSW 2006, Australia
[2] Sydney Childrens Hosp Network, Paediat Gait Anal Serv New South Wales, Westmead, NSW 2145, Australia
关键词
load cell dynamometer; isometric muscle strength; outcome measures; clinical outcome assessments; clinical trials and cohort studies; REFERENCE VALUES; AGED; 20; RELIABILITY; EXTREMITY; CHILDREN; VALIDITY;
D O I
10.3390/s24061861
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Muscle strength is routinely measured in patients with neuromuscular disorders by hand-held dynamometry incorporating a wireless load cell to evaluate disease severity and therapeutic efficacy, with magnitude of effect often based on normative reference values. While several hand-held dynamometers exist, their interchangeability is unknown which limits the utility of normative data. We investigated the variability between six commercially available dynamometers for measuring the isometric muscle strength of four muscle groups in thirty healthy individuals. Following electro-mechanical sensor calibration against knowns loads, Citec, Nicholas, MicroFET2, and Commander dynamometers were used to assess the strength of ankle dorsiflexors, hip internal rotators, and shoulder external rotators. Citec, Jamar Plus, and Baseline Hydraulic dynamometers were used to capture hand grip strength. Variability between dynamometers was represented as percent differences and statistical significance was calculated with one-way repeated measures ANOVA. Percent differences between dynamometers ranged from 0.2% to 16%. No significant differences were recorded between the Citec, Nicholas, and MicroFET2 dynamometers (p > 0.05). Citec grip strength measures differed to the Jamar Plus and Baseline Hydraulic dynamometers (p < 0.01). However, when controlling for grip circumference, they were comparable (p > 0.05). Several hand-held dynamometers can be used interchangeably to measure upper and lower limb strength, thereby maximising the use of normative reference values.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] RELIABILITY OF HAND-HELD DYNAMOMETRY IN MEASURING MUSCLE STRENGTH
    BURDETT, RG
    WHITNEY, SL
    [J]. PHYSICAL THERAPY, 1987, 67 (05): : 748 - 748
  • [2] Reliability of a Trunk Flexion and Extensor Muscle Strength Test with Hand-Held and Isokinetic Dynamometers in Female Athletes
    Juan-Recio, Casto
    Prat-Luri, Amaya
    Barbado, David
    Vera-Garcia, Francisco J.
    Moreno-Perez, Victor
    [J]. JOURNAL OF HUMAN KINETICS, 2024, 92 : 43 - 52
  • [3] A comparison of 3 hand-held dynamometers used to measure hip abduction strength
    Fenter, PC
    Bellew, JW
    Pitts, T
    Kay, R
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2003, 17 (03) : 531 - 535
  • [4] Normative values for isometric muscle force measurements obtained with hand-held dynamometers
    Andrews, AW
    Thomas, MW
    Bohannon, RW
    [J]. PHYSICAL THERAPY, 1996, 76 (03): : 248 - 259
  • [5] EVALUATION OF A HAND-HELD DYNAMOMETER FOR MEASURING MUSCLE STRENGTH UNDER FIELD CONDITIONS
    METCALF, WK
    STUBERG, WA
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1986, 380 : P64 - P64
  • [6] COMPARABILITY OF FORCE MEASUREMENTS OBTAINED WITH DIFFERENT STRAIN-GAUGE HAND-HELD DYNAMOMETERS
    BOHANNON, RW
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1993, 18 (04): : 564 - 567
  • [7] Reliability of hand-held dynamometer in measuring gluteus medius isometric muscle strength in healthy population
    Soomro, Rabail Rani
    Karimi, Hossein
    Gillani, Syed Amir
    [J]. PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2022, 38 (05) : 1238 - 1242
  • [8] Measuring muscle strength for people with chronic obstructive pulmonary disease: Retest reliability of hand-held dynamometry
    O'Shea, Simone D.
    Taylor, Nicholas F.
    Paratz, Jennifer D.
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2007, 88 (01): : 32 - 36
  • [9] Validity and usefulness of hand-held dynamometry for measuring muscle strength in community-dwelling older persons
    Abizanda, Pedro
    Luis Navarro, Jose
    Isabel Garcia-Tomas, Maria
    Lopez-Jimenez, Esther
    Martinez-Sanchez, Esther
    Paterna, Gema
    [J]. ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2012, 54 (01) : 21 - 27
  • [10] HAND-HELD DYNAMOMETRY - STABILITY OF MUSCLE STRENGTH OVER MULTIPLE MEASUREMENTS
    BOHANNON, RW
    [J]. CLINICAL BIOMECHANICS, 1987, 2 (02) : 74 - 77