Overall evaluability of low dose protocol for computed tomography angiography of thoracic aorta using 80kV and iterative reconstruction algorithm using different concentration contrast media

被引:8
|
作者
Annoni, Andrea Daniele [1 ]
Mancini, Maria E. [1 ]
Andreini, Daniele [1 ,2 ]
Formenti, Alberto [1 ]
Mushtaq, Saima [1 ]
Nobili, Enrica [1 ]
Guglielmo, Marco [1 ]
Baggiano, Andrea [1 ]
Conte, Edoardo [1 ]
Pepi, Mauro [1 ]
机构
[1] IRCCS, Ctr Cardiol Monzino, Via C Parea 4, I-20138 Milan, Italy
[2] Univ Milan, Dept Cardiovasc Sci & Community Hlth, Milan, Italy
关键词
CT angiography; dose reduction; ECG gated scan protocols; contrast agents; thoracic aorta; ROW CT ANGIOGRAPHY; DIAGNOSTIC-ACCURACY; IMAGE-QUALITY; IODINE CONCENTRATION; MULTIDETECTOR CT; CHEST CT; ENHANCEMENT; REDUCTION; MDCT; KV;
D O I
10.1111/1754-9485.12608
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionMultidetector Computed Tomography Angiography (MDCTA) is presently the imaging modality of choice for aortic disease. However, the effective radiation dose and the risk related to the use of contrast agents associated with MDCTA is an issue of concern. Aim of this study was to assess image quality of a low dose ECG-gated MDCTA of thoracic aorta using different concentration contrast media without tailored injection protocol. MethodsTwo-hundred patients were randomised into four different scan protocols: Group A (Iodixanol 320 and 80 Kvp tube voltage), Group B (Iodixanol 320 and 100Kvp tube voltage), Group C (Iomeprol 400 and 80Kvp tube voltage) and Group D (Iomeprol 400 and 100Kvp tube voltage). Image quality, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and effective dose (ED) were compared among groups. ResultsNo significant differences in image noise, SNR and CNR between groups with the same tube voltage. Significant differences in SNR and CNR were found among groups with 80kV versus groups using 100kV but without differences in terms of image quality. ED was significantly lower in groups with 80kV. ConclusionsMultidetector Computed Tomography Angiography protocols using 80kV and low concentration contrast media are feasible without need of tailored injection protocols.
引用
收藏
页码:614 / 621
页数:8
相关论文
共 50 条
  • [41] Computed tomography of the cervical spine: comparison of image quality between a standard-dose and a low-dose protocol using filtered back-projection and iterative reconstruction
    Becce, Fabio
    Ben Salah, Yosr
    Verdun, Francis R.
    Vande Berg, Bruno C.
    Lecouvet, Frederic E.
    Meuli, Reto
    Omoumi, Patrick
    SKELETAL RADIOLOGY, 2013, 42 (07) : 937 - 945
  • [42] Computed tomography of the cervical spine: comparison of image quality between a standard-dose and a low-dose protocol using filtered back-projection and iterative reconstruction
    Fabio Becce
    Yosr Ben Salah
    Francis R. Verdun
    Bruno C. Vande Berg
    Frederic E. Lecouvet
    Reto Meuli
    Patrick Omoumi
    Skeletal Radiology, 2013, 42 : 937 - 945
  • [43] Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose
    Eun-Suk Cho
    Tae-Sub Chung
    Sung Jun Ahn
    KyoungHoon Chong
    Jang Hun Baek
    Sang Hyun Suh
    European Radiology, 2015, 25 : 1421 - 1430
  • [44] Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose
    Cho, Eun-Suk
    Chung, Tae-Sub
    Ahn, Sung Jun
    Chong, KyoungHoon
    Baek, Jang Hun
    Suh, Sang Hyun
    EUROPEAN RADIOLOGY, 2015, 25 (05) : 1421 - 1430
  • [45] Investigation of the Radiation Dose in Computed Micro Tomography Using the Medipix3 Semiconductor Detector in Combination with an Iterative Reconstruction Algorithm
    Fischer, F.
    Procz, S.
    Fauler, A.
    Fiederle, M.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [46] Low-Dose Pelvic Computed Tomography Using Adaptive Iterative Dose Reduction 3-Dimensional Algorithm: A Phantom Study
    Onishi, Hiromitsu
    Kockelkoren, Remko
    Kim, Tonsok
    Hori, Masatoshi
    Nakamoto, Atsushi
    Tsuboyama, Takahiro
    Sakane, Makoto
    Tatsumi, Mitsuaki
    Uranishi, Ayumi
    Tanaka, Toshiya
    Taniguchi, Akira
    Enchi, Yukihiro
    Satoh, Kazuhiko
    Tomiyama, Noriyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (04) : 629 - 634
  • [47] Low-Dose Computed Tomography of the Chest Using Iterative Reconstruction Versus Filtered Back Projection: Comparison of Image Quality
    Lee, Youkyung
    Jin, Kwang Nam
    Lee, Nyoung Keun
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (05) : 512 - 517
  • [48] Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients
    François Pontana
    Alain Duhamel
    Julien Pagniez
    Thomas Flohr
    Jean-Baptiste Faivre
    Anne-Lise Hachulla
    Jacques Remy
    Martine Remy-Jardin
    European Radiology, 2011, 21 : 636 - 643
  • [49] Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients
    Pontana, Francois
    Duhamel, Alain
    Pagniez, Julien
    Flohr, Thomas
    Faivre, Jean-Baptiste
    Hachulla, Anne-Lise
    Remy, Jacques
    Remy-Jardin, Martine
    EUROPEAN RADIOLOGY, 2011, 21 (03) : 636 - 643
  • [50] Application of 80-kVp tube voltage, low-concentration contrast agent and iterative reconstruction in coronary CT angiography: evaluation of image quality and radiation dose
    Wu, Qiyong
    Wang, Yong
    Kai, Huihua
    Wang, Tao
    Tang, Xiaoqiang
    Wang, Xiaoqin
    Pan, Changjie
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2016, 70 (9B) : B50 - B55