Overall evaluability of low dose protocol for computed tomography angiography of thoracic aorta using 80kV and iterative reconstruction algorithm using different concentration contrast media

被引:8
|
作者
Annoni, Andrea Daniele [1 ]
Mancini, Maria E. [1 ]
Andreini, Daniele [1 ,2 ]
Formenti, Alberto [1 ]
Mushtaq, Saima [1 ]
Nobili, Enrica [1 ]
Guglielmo, Marco [1 ]
Baggiano, Andrea [1 ]
Conte, Edoardo [1 ]
Pepi, Mauro [1 ]
机构
[1] IRCCS, Ctr Cardiol Monzino, Via C Parea 4, I-20138 Milan, Italy
[2] Univ Milan, Dept Cardiovasc Sci & Community Hlth, Milan, Italy
关键词
CT angiography; dose reduction; ECG gated scan protocols; contrast agents; thoracic aorta; ROW CT ANGIOGRAPHY; DIAGNOSTIC-ACCURACY; IMAGE-QUALITY; IODINE CONCENTRATION; MULTIDETECTOR CT; CHEST CT; ENHANCEMENT; REDUCTION; MDCT; KV;
D O I
10.1111/1754-9485.12608
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionMultidetector Computed Tomography Angiography (MDCTA) is presently the imaging modality of choice for aortic disease. However, the effective radiation dose and the risk related to the use of contrast agents associated with MDCTA is an issue of concern. Aim of this study was to assess image quality of a low dose ECG-gated MDCTA of thoracic aorta using different concentration contrast media without tailored injection protocol. MethodsTwo-hundred patients were randomised into four different scan protocols: Group A (Iodixanol 320 and 80 Kvp tube voltage), Group B (Iodixanol 320 and 100Kvp tube voltage), Group C (Iomeprol 400 and 80Kvp tube voltage) and Group D (Iomeprol 400 and 100Kvp tube voltage). Image quality, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and effective dose (ED) were compared among groups. ResultsNo significant differences in image noise, SNR and CNR between groups with the same tube voltage. Significant differences in SNR and CNR were found among groups with 80kV versus groups using 100kV but without differences in terms of image quality. ED was significantly lower in groups with 80kV. ConclusionsMultidetector Computed Tomography Angiography protocols using 80kV and low concentration contrast media are feasible without need of tailored injection protocols.
引用
收藏
页码:614 / 621
页数:8
相关论文
共 50 条
  • [31] Cardiac Computed Tomography Radiation Dose Reduction Using Interior Reconstruction Algorithm With the Aorta and Vertebra as Known Information
    Bharkhada, Deepak
    Yu, Hengyong
    Ge, Shuping
    Carr, J. Jeffrey
    Wang, Ge
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (03) : 338 - 347
  • [32] Comparison of image quality and radiation dose in computed tomography angiography of the peripheral arteries using tube voltage of 80 kV versus 100 kV
    Pernas, R. Oca
    Delgado Sanchez-Gracian, C.
    Tardaguila de la Fuente, G.
    Fernandez del Valle, A.
    Silva Priegue, N.
    Gonzalez Vazquez, M.
    Trinidad Lopez, C.
    RADIOLOGIA, 2014, 56 (06): : 541 - 547
  • [33] Low tube voltage computed tomography urography using low-concentration contrast media: Comparison of image quality in conventional computed tomography urography
    Hwang, Inpyeong
    Cho, Jeong Yeon
    Kim, Sang Youn
    Oh, Seung-June
    Ku, Ja Hyeon
    Lee, Joongyup
    Kim, Seung Hyup
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (12) : 2454 - 2463
  • [34] Late enhancement using multidetector row computer tomography:: A feasibility study with low dose 80 kV protocol
    Reimann, Anja J.
    Kuettner, Axel
    Klumpp, Bernhard
    Heuschmid, Martin
    Schumacher, Felix
    Teufel, Matthias
    Beck, Torsten
    Burgstahler, Christof
    Schroeder, Steffen
    Claussen, Claus D.
    Kopp, Andreas F.
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 66 (01) : 127 - 133
  • [35] Improved Image Quality and Decreased Radiation Dose of Lower Extremity Computed Tomography Angiography Using Low-Tube-Voltage and Adaptive Iterative Reconstruction
    Pan, Yu-Ning
    Li, Ai-Jing
    Chen, Zhao-Qian
    Ren, Da-Wei
    Zhang, Jie
    Jiang, Mao-Qing
    Huang, Qiu-Li
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (02) : 272 - 276
  • [36] Low concentration contrast medium for dual-source computed tomography coronary angiography by a combination of iterative reconstruction and low-tube-voltage technique: Feasibility study
    Zheng, Minwen
    Liu, Ying
    Wei, Mengqi
    Wu, Yongjie
    Zhao, Hongliang
    Li, Jian
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) : E92 - E99
  • [37] Evaluation of Low-dose Computed Tomography Images Reconstructed Using Artificial Intelligence-based Adaptive Filtering for Denoising: A Comparison with Computed Tomography Reconstructed with Iterative Reconstruction Algorithm
    Kulkarni, Suyash
    Patil, Vasundhara
    Nene, Aniruddha
    Shetty, Nitin
    Choudhari, Amitkumar
    Joshi, Akansha
    Pramesh, C. S.
    Baheti, Akshay
    Mahadik, Kalpesh
    JOURNAL OF MEDICAL PHYSICS, 2025, 50 (01) : 108 - 117
  • [38] Iterative reconstruction for low-dose cerebral perfusion computed tomography using prior image induced diffusion tensor
    Niu, Shanzhou
    Liu, Hong
    Zhang, Mengzhen
    Wang, Min
    Wang, Jing
    Ma, Jianhua
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (11):
  • [39] Ultra-low radiation dose CT angiography of the lower extremity using the iterative model reconstruction (IMR) algorithm
    Qian, W-L.
    Zhou, D. -J.
    Jiang, Y.
    Feng, C.
    Chen, Q.
    Wang, H.
    Zhang, J. -B.
    Xu, J. -M.
    CLINICAL RADIOLOGY, 2018, 73 (11) : 985.e13 - 985.e19
  • [40] Application of Adaptive Statistical Iterative Reconstruction-V With Combination of 80 kV for Reducing Radiation Dose and Improving Image Quality in Renal Computed Tomography Angiography for Slim Patients
    Ren, Zhanli
    Zhang, Xirong
    Hu, Zhijun
    Li, Dou
    Liu, Zhentang
    Wei, Donghong
    Jia, Yongjun
    Yu, Nan
    Yu, Yong
    Lei, Yuxin
    Chen, Xiaoxia
    Guo, Changyi
    Ren, Zhanliang
    He, Taiping
    ACADEMIC RADIOLOGY, 2019, 26 (11) : E324 - E332