Overall evaluability of low dose protocol for computed tomography angiography of thoracic aorta using 80kV and iterative reconstruction algorithm using different concentration contrast media

被引:8
|
作者
Annoni, Andrea Daniele [1 ]
Mancini, Maria E. [1 ]
Andreini, Daniele [1 ,2 ]
Formenti, Alberto [1 ]
Mushtaq, Saima [1 ]
Nobili, Enrica [1 ]
Guglielmo, Marco [1 ]
Baggiano, Andrea [1 ]
Conte, Edoardo [1 ]
Pepi, Mauro [1 ]
机构
[1] IRCCS, Ctr Cardiol Monzino, Via C Parea 4, I-20138 Milan, Italy
[2] Univ Milan, Dept Cardiovasc Sci & Community Hlth, Milan, Italy
关键词
CT angiography; dose reduction; ECG gated scan protocols; contrast agents; thoracic aorta; ROW CT ANGIOGRAPHY; DIAGNOSTIC-ACCURACY; IMAGE-QUALITY; IODINE CONCENTRATION; MULTIDETECTOR CT; CHEST CT; ENHANCEMENT; REDUCTION; MDCT; KV;
D O I
10.1111/1754-9485.12608
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionMultidetector Computed Tomography Angiography (MDCTA) is presently the imaging modality of choice for aortic disease. However, the effective radiation dose and the risk related to the use of contrast agents associated with MDCTA is an issue of concern. Aim of this study was to assess image quality of a low dose ECG-gated MDCTA of thoracic aorta using different concentration contrast media without tailored injection protocol. MethodsTwo-hundred patients were randomised into four different scan protocols: Group A (Iodixanol 320 and 80 Kvp tube voltage), Group B (Iodixanol 320 and 100Kvp tube voltage), Group C (Iomeprol 400 and 80Kvp tube voltage) and Group D (Iomeprol 400 and 100Kvp tube voltage). Image quality, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and effective dose (ED) were compared among groups. ResultsNo significant differences in image noise, SNR and CNR between groups with the same tube voltage. Significant differences in SNR and CNR were found among groups with 80kV versus groups using 100kV but without differences in terms of image quality. ED was significantly lower in groups with 80kV. ConclusionsMultidetector Computed Tomography Angiography protocols using 80kV and low concentration contrast media are feasible without need of tailored injection protocols.
引用
收藏
页码:614 / 621
页数:8
相关论文
共 50 条
  • [21] Impact of 80 kVp with iterative reconstruction algorithm and low-dose contrast medium on the image quality of craniocervical CT angiography
    Chen, Po-An
    Chen, Chih-Wei
    Chou, Chiung-Chen
    Fu, Jui-Hsun
    Wang, Po-Chin
    Hsu, Shuo-Hsiu
    Lai, Ping-Hong
    CLINICAL IMAGING, 2020, 68 (68) : 124 - 130
  • [22] Estimated Radiation Dose of Coronary Computed Tomography Angiography Using Adaptive Statistical Iterative Reconstruction: A Multicenter Study
    LaBounty, Troy M.
    Earls, James
    Leipsic, Jonathon
    Heilbron, Brett
    Mancini, G. B. John
    Lin, Fay Y.
    Min, James K.
    CIRCULATION, 2009, 120 (18) : S334 - S334
  • [23] Effects of Model-Based Iterative Reconstruction on Image Quality for Low-Dose Computed Tomographic Angiography of the Thoracic Aorta in a Swine Model
    Caywood, Devin
    Paxton, Ben
    Boll, Daniel
    Nelson, Rendon
    Kim, Charles
    Lowry, Carolyn
    Seaman, Danielle
    Roos, Justus E.
    Hurwitz, Lynne M.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (02) : 196 - 201
  • [24] 256 Slice Multi-detector Computed Tomography Thoracic Aorta Computed Tomography Angiography: Improved Luminal Opacification Using a Patient-Specific Contrast Protocol and Caudocranial Scan Acquisition
    Saade, Charbel
    El-Merhi, Fadi
    El-Achkar, Bassam
    Kerek, Racha
    Vogl, Thomas J.
    Maroun, Gilbert Georges
    Jamjoom, Lamia
    Al-Mohiy, Hussain
    Naffaa, Lena
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (06) : 964 - 970
  • [25] Low-Contrast and Low-Radiation Dose Protocol in Cardiac Computed Tomography: Usefulness of Low Tube Voltage and Knowledge-Based Iterative Model Reconstruction Algorithm
    Iyama, Yuji
    Nakaura, Takeshi
    Yokoyama, Koichi
    Kidoh, Masafumi
    Harada, Kazunori
    Oda, Seitaro
    Tokuyasu, Shinichi
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (06) : 941 - 947
  • [26] Clinical Feasibility of a Low-dose Computed Tomography Angiography (CTA) Protocol with an Iterative Reconstruction Algorithm in Preoperative Examinations for Anterolateral Thigh Perforator Flap Surgery
    Tang, Wen
    Cao, Min
    Chen, Qilong
    Yang, Hong
    Yang, Ying
    IRANIAN JOURNAL OF RADIOLOGY, 2023, 20 (01)
  • [27] Double low-dose computed tomography (CT) angiography of craniocervical arteries using a test bolus of diluted contrast medium and a personalized contrast protocol
    Li, J.
    Wei, W. -F.
    Song, L. -N.
    Mei, X. -Y.
    Yuan, X. -S.
    He, J. -B.
    Jiang, L. -Z
    Li, H. -Y
    Wu, H. -L
    Chen, J. -P.
    CLINICAL RADIOLOGY, 2024, 79 (11)
  • [28] Dose Reduction and Low-Contrast Detectability Using Iterative CBCT Reconstruction Algorithm for Radiotherapy
    Washio, Hayate
    Ohira, Shingo
    Funama, Yoshinori
    Ueda, Yoshihiro
    Morimoto, Masahiro
    Kanayama, Naoyuki
    Isono, Masaru
    Inui, Shoki
    Nitta, Yuya
    Miyazaki, Masayoshi
    Teshima, Teruki
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2022, 21
  • [29] Computed Tomography Angiography Combined With Knowledge-Based Iterative Algorithm for Transcatheter Aortic Valve Implantation Planning: Image Quality and Radiation Dose Exposure With Low-kV and Low-Contrast-Medium Protocol
    Ippolito, Davide
    Riva, Luca
    Franzesi, Cammillo Talei
    De Vito, Andrea
    Cangiotti, Cecilia
    Crespi, Andrea
    Corso, Rocco
    Sironi, Sandro
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (01) : 13 - 19
  • [30] Low kilovoltage and low contrast volume neck CT protocol using iterative reconstruction techniques: A comparison with standard dose protocol
    Chhetri, Shubham
    Pendem, Saikiran
    Bharath, J. L.
    Priyanka
    RADIATION PHYSICS AND CHEMISTRY, 2022, 193