Comparison of the BacT/Alert PF pediatric FAN blood culture bottle with the standard pediatric blood culture bottle, the Pedi-BacT

被引:16
|
作者
Krisher, KK
Gibb, P
Corbett, S
Church, D
机构
[1] Childrens Med Ctr, Clin Microbiol Lab, Dallas, TX 75235 USA
[2] Calgary Lab Serv, Calgary, AB TC3 0J5, Canada
关键词
D O I
10.1128/JCM.39.8.2880-2883.2001
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The performance of the BacT/Alert PF (Organon-Teknika Corp., Durham, N.C.), a new nonvented pediatric FAN blood culture bottle, was compared to that of the original pediatric bottle, the Pedi-BacT, with matched aerobic cultures obtained from two separate facilities. A total of 244 clinically significant isolates were recovered from 4,015 compliant pairs. Among the positive cultures, 170 (70%) isolates were detected in both the BacT/Alert PF and the Pedi-BacT bottles, while 47 (19%) isolates were recovered in the BacT/Alert PIT bottle only and 27 (11%) isolates were recovered in the Pedi-BacT bottle only. Although isolation of specific microorganisms was comparable for the two bottles, the total number of organisms recovered by the BacT/Alert PF was greater than that by the Pedi-BacT (P = 0.0272). In addition, more organisms were recovered by the BacT/Alert PF bottle from the blood of patients receiving antimicrobial therapy (P = 0.0180). Overall time to detection was similar for the two bottles; however, a significantly decreased mean time to detection was recorded for yeast from the BacT/Alert PF bottle (22.9 h; P = 0.0001) and staphylococci from the Pedi-BacT bottle (22.5 h; P = 0.0056). One false-negative culture and five false-positive cultures occurred with the Pedi-BacT bottle, compared to one false-positive culture with the BacT/Alert PF bottle. The BacT/Alert PF bottle is a reliable blood culture bottle for pediatric blood culture specimens and may offer improved recovery of microbes from patients on antimicrobial therapy. The use of the nonvented bottle will both facilitate bottle processing and decrease expenditures for materials due to the elimination of the venting needles required for the original vented bottles.
引用
收藏
页码:2880 / 2883
页数:4
相关论文
共 50 条
  • [41] GROWTH AND DETECTION OF FILAMENTOUS FUNGI IN THE BACT/ALERT BLOOD CULTURE SYSTEM
    BREATHNACH, A
    EVANS, J
    JOURNAL OF CLINICAL PATHOLOGY, 1995, 48 (07) : 670 - 672
  • [42] Multicenter Clinical Evaluation of BacT/Alert Virtuo Blood Culture System
    Jacobs, Michael R.
    Mazzulli, Tony
    Hazen, Kevin C.
    Good, Caryn E.
    Abdelhamed, Ayman M.
    Lo, Pauline
    Shum, Bianche
    Roman, Katharine P.
    Robinson, Danielle C.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2017, 55 (08) : 2413 - 2421
  • [43] Evaluation of a new generation culture bottle with the BacT/ALERT® 3D culture system with 8 contaminating organisms in platelets
    Brecher, ME
    Heath, D
    Hay, S
    Rothenberg, S
    Stutzman, LC
    TRANSFUSION, 2001, 41 (09) : 33S - 33S
  • [44] CONTROLLED COMPARISON OF THE BACT ALERT AND BACTEC-660/730 NONRADIOMETRIC BLOOD CULTURE SYSTEMS
    WILSON, ML
    WEINSTEIN, MP
    REIMER, LG
    MIRRETT, S
    RELLER, LB
    JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (02) : 323 - 329
  • [45] Comparison of the Bactec 9240 and BacT/Alert Blood Culture Systems for Evaluation of Placental Cord Blood for Transfusion in Neonates
    Riedel, Stefan
    Junkins, Alan
    Stamper, Paul D.
    Cress, Gretchen
    Widness, John A.
    Doern, Gary V.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (06) : 1645 - 1649
  • [46] Comparison of BacT/Alert microbial detection system with conventional blood culture method in neonatal sepsis
    Hasan, Azra S.
    Uppal, Preena
    Arya, Sugandha
    Capoor, Malini R.
    Nair, Deepthi
    Chellani, Harish
    Deb, Monorama
    Aggarwal, Pushpa
    JOURNAL OF PEDIATRIC INFECTIOUS DISEASES, 2008, 3 (01) : 21 - 25
  • [47] Blood Culture Bottle and Standard Culture Bottle Methods for Detection of Bacterial Pathogens in Parapneumonic Pleural Effusion
    Charoentunyarak, Surapan
    Kananuraks, Sarassawan
    Chindaprasirt, Jarin
    Limpawattana, Panita
    Sawanyawisuth, Kittisak
    JUNDISHAPUR JOURNAL OF MICROBIOLOGY, 2015, 8 (10)
  • [48] Use of simulated blood cultures for time to detection comparison between BacT/ALERT™ and BACTEC™ 9240 blood culture systems
    FrancescoViganò, E
    Vasconi, E
    Agrappi, C
    Clerici, P
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2002, 44 (03) : 235 - 240
  • [49] Comparative evaluation of BACTEC FX, BacT/ALERT 3D, and BacT/ALERT VIRTUO-automated blood culture systems using simulated blood cultures
    Li, Zhengkang
    Liu, Suling
    Chen, Huimin
    Zhang, Xinqiang
    Ling, Yong
    Zhang, Ni
    Hou, Tieying
    ACTA CLINICA BELGICA, 2022, 77 (01) : 71 - 78
  • [50] Evaluation of BACTEC Plus aerobic and anaerobic blood culture bottles and BacT/Alert FAN aerobic and anaerobic blood culture bottles for the detection of bacteremia in ICU patients
    Roh, Kyoung Ho
    Kim, Ju Yeon
    Kim, Ha Nui
    Lee, Hye Jin
    Sohn, Jang Wook
    Kim, Min Ja
    Cho, Yunjung
    Kim, Young Kee
    Lee, Chang Kyu
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2012, 73 (03) : 239 - 242