Evaluation of BACTEC Plus aerobic and anaerobic blood culture bottles and BacT/Alert FAN aerobic and anaerobic blood culture bottles for the detection of bacteremia in ICU patients

被引:31
|
作者
Roh, Kyoung Ho [1 ]
Kim, Ju Yeon [1 ]
Kim, Ha Nui [1 ]
Lee, Hye Jin [1 ]
Sohn, Jang Wook [2 ]
Kim, Min Ja [2 ]
Cho, Yunjung [1 ]
Kim, Young Kee [1 ]
Lee, Chang Kyu [1 ]
机构
[1] Korea Univ, Coll Med, Dept Lab Med, Seoul 136705, South Korea
[2] Korea Univ, Coll Med, Dept Internal Med, Seoul 136705, South Korea
关键词
Blood culture; Evaluation; BACTEC; BacT/Alert; Culture bottle; Time to detection; STREAM INFECTIONS; FUNGEMIA; SYSTEMS; MEDIA; TIME;
D O I
10.1016/j.diagmicrobio.2012.03.022
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Blood culture is the most valuable laboratory test for the diagnosis of bacteremia and sepsis. The BACTEC FX and BacT/Alert 3D automated blood culture systems are commonly used in Korean health care facilities. A controlled clinical evaluation of the resin-containing BACTEC Plus aerobic (BA) and anaerobic (BN), and the charcoal-containing FAN aerobic (FA) and anaerobic (FN) bottles using blood from intensive care unit (ICU) patients was designed. The performances of these 2 systems with media containing particle absorbing antimicrobial agents were evaluated using the culture positivity rate and time to detection (TTD). TTD was collected using data management systems, either the Epicenter (BD Diagnostic Systems) or the hospital laboratory information system. A total of 1539 four-bottle sets were collected from 270 patients in medical and surgical ICUs. Blood culture samples included 1539 bottles each of BA, BN, FA, and FN, and yielded 113 (7.3%), 90 (5.8%), 104 (6.8%), and 80 (5.2%) positive bacterial or fungal isolates, respectively. There were significant differences between the resin-containing BA and BN samples in culture positivity and also between the charcoal-containing FA and FN samples, especially for Escherichia coli (25/27 versus 17/27, P < 0.05) and Acinetobacter baumannii (14/15 versus 7/15, P < 0.05). Significantly shorter recovery time was observed in BACTEC Plus aerobic bottles than in FAN aerobic bottles (17.2 and 24.7 h, respectively) (P < 0.001). (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:239 / 242
页数:4
相关论文
共 50 条
  • [1] A comparative evaluation of BACT/ALERT FA PLUS and FN PLUS blood culture bottles and BD BACTEC Plus Aerobic and Anaerobic blood culture bottles for antimicrobial neutralization
    Chung, Yousun
    Kim, In-Hee
    Han, Minje
    Kim, Hyun Soo
    Kim, Han-Sung
    Song, Wonkeun
    Kim, Jae-Seok
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2019, 38 (12) : 2229 - 2233
  • [2] A comparative evaluation of BACT/ALERT FA PLUS and FN PLUS blood culture bottles and BD BACTEC Plus Aerobic and Anaerobic blood culture bottles for antimicrobial neutralization
    Yousun Chung
    In-Hee Kim
    Minje Han
    Hyun Soo Kim
    Han-Sung Kim
    Wonkeun Song
    Jae-Seok Kim
    European Journal of Clinical Microbiology & Infectious Diseases, 2019, 38 : 2229 - 2233
  • [3] CONTROLLED EVALUATION OF BACT ALERT STANDARD AEROBIC AND FAN AEROBIC BLOOD CULTURE BOTTLES FOR DETECTION OF BACTEREMIA AND FUNGEMIA
    WEINSTEIN, MP
    MIRRETT, S
    REIMER, LG
    WILSON, ML
    SMITHELEKES, S
    CHUARD, CR
    JOHO, KL
    RELLER, LB
    JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (04) : 978 - 981
  • [4] CONTROLLED EVALUATION OF BACT ALERT STANDARD ANAEROBIC AND FAN ANAEROBIC BLOOD CULTURE BOTTLES FOR THE DETECTION OF BACTEREMIA AND FUNGEMIA
    WILSON, ML
    WEINSTEIN, MP
    MIRRETT, S
    REIMER, LG
    FELDMAN, RJ
    CHUARD, CR
    RELLER, LB
    JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (09) : 2265 - 2270
  • [5] Clinical importance of increased sensitivity of BacT/Alert FAN aerobic and anaerobic blood culture bottles
    McDonald, LC
    Fune, J
    Gaido, LB
    Weinstein, MP
    Reimer, LG
    Flynn, TM
    Wilson, ML
    Mirrett, S
    Reller, LB
    JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (09) : 2180 - 2184
  • [6] Reassessment of the routine anaerobic culture and incubation time in the BacT/alert FAN blood culture bottles
    Cornish, N
    Kirkley, BA
    Easley, KA
    Washington, JA
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1999, 35 (02) : 93 - 99
  • [7] CONTROLLED CLINICAL-EVALUATION OF BACTEC PLUS AEROBIC/F AND BACT/ALERT AEROBIC FAN BOTTLES FOR DETECTION OF BLOOD-STREAM INFECTIONS
    POHLMAN, JK
    KIRKLEY, BA
    EASLEY, KA
    BASILLE, BA
    WASHINGTON, JA
    JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (11) : 2856 - 2858
  • [8] Comparison of recovery of blood culture isolates from two BacT/ALERT FAN aerobic blood culture bottles with recovery from one FAN aerobic bottle and one FAN anaerobic bottle
    Riley, JA
    Heiter, BJ
    Bourbeau, PP
    JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (01) : 213 - 217
  • [9] Detection of simulated candidemia by the BACTEC 9240 system with plus Aerobic/F and Anaerobic/F blood culture bottles
    Horvath, LL
    Hospenthal, DR
    Murray, CK
    Dooley, DP
    JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (10) : 4714 - 4717
  • [10] Recovery and time to growth of isolates in blood culture bottles: Comparison of BD Bactec Plus Aerobic/F and BD Bactec Plus Anaerobic/F bottles
    Passerini, Rita
    Cassatella, Maria Cristina
    Salvatici, Michela
    Bottari, Fabio
    Mauro, Cristian
    Radice, Davide
    Sandri, Maria Teresa
    SCANDINAVIAN JOURNAL OF INFECTIOUS DISEASES, 2014, 46 (04) : 288 - 293