Evaluation of BACTEC Plus aerobic and anaerobic blood culture bottles and BacT/Alert FAN aerobic and anaerobic blood culture bottles for the detection of bacteremia in ICU patients

被引:31
|
作者
Roh, Kyoung Ho [1 ]
Kim, Ju Yeon [1 ]
Kim, Ha Nui [1 ]
Lee, Hye Jin [1 ]
Sohn, Jang Wook [2 ]
Kim, Min Ja [2 ]
Cho, Yunjung [1 ]
Kim, Young Kee [1 ]
Lee, Chang Kyu [1 ]
机构
[1] Korea Univ, Coll Med, Dept Lab Med, Seoul 136705, South Korea
[2] Korea Univ, Coll Med, Dept Internal Med, Seoul 136705, South Korea
关键词
Blood culture; Evaluation; BACTEC; BacT/Alert; Culture bottle; Time to detection; STREAM INFECTIONS; FUNGEMIA; SYSTEMS; MEDIA; TIME;
D O I
10.1016/j.diagmicrobio.2012.03.022
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Blood culture is the most valuable laboratory test for the diagnosis of bacteremia and sepsis. The BACTEC FX and BacT/Alert 3D automated blood culture systems are commonly used in Korean health care facilities. A controlled clinical evaluation of the resin-containing BACTEC Plus aerobic (BA) and anaerobic (BN), and the charcoal-containing FAN aerobic (FA) and anaerobic (FN) bottles using blood from intensive care unit (ICU) patients was designed. The performances of these 2 systems with media containing particle absorbing antimicrobial agents were evaluated using the culture positivity rate and time to detection (TTD). TTD was collected using data management systems, either the Epicenter (BD Diagnostic Systems) or the hospital laboratory information system. A total of 1539 four-bottle sets were collected from 270 patients in medical and surgical ICUs. Blood culture samples included 1539 bottles each of BA, BN, FA, and FN, and yielded 113 (7.3%), 90 (5.8%), 104 (6.8%), and 80 (5.2%) positive bacterial or fungal isolates, respectively. There were significant differences between the resin-containing BA and BN samples in culture positivity and also between the charcoal-containing FA and FN samples, especially for Escherichia coli (25/27 versus 17/27, P < 0.05) and Acinetobacter baumannii (14/15 versus 7/15, P < 0.05). Significantly shorter recovery time was observed in BACTEC Plus aerobic bottles than in FAN aerobic bottles (17.2 and 24.7 h, respectively) (P < 0.001). (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:239 / 242
页数:4
相关论文
共 50 条
  • [21] Comparison of the BacT/Alert FAN aerobic and the Difco ESP 80A aerobic bottles for pediatric blood cultures
    WelbySellenriek, PL
    Keller, DS
    Ferrett, RJ
    Storch, GA
    JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (05) : 1166 - 1171
  • [22] Predictive value of isolating Pseudomonas aeruginosa from aerobic and anaerobic blood culture bottles
    Enoch, DA
    Simpson, AJH
    Kibbler, CC
    JOURNAL OF MEDICAL MICROBIOLOGY, 2004, 53 (11) : 1151 - 1154
  • [23] Inactivation of Clinically Frequently Used Antimicrobial Agents By BacT/ALERT FAN Plus and BACTEC Aerobic and Anaerobic Culture Media in Simulated Blood Cultures: First Comparative Evaluation in China Mainland
    Xu, Xiuyu
    Wei, Qiang
    Wang, Zhu
    Yan, Jie
    Wang, Huijuan
    Xia, Yun
    INFECTION AND DRUG RESISTANCE, 2021, 14 : 163 - 172
  • [24] CONTROLLED EVALUATION OF BACTEC PLUS-27 AND ROCHE SEPTI-CHEK ANAEROBIC BLOOD CULTURE BOTTLES
    WILSON, ML
    HARRELL, LJ
    MIRRETT, S
    WEINSTEIN, MP
    STRATTON, CW
    RELLER, LB
    JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (01) : 63 - 66
  • [25] Evaluation of Bactec Mycosis IC/F and Plus Aerobic/F Blood Culture Bottles for Detection of Candida in the Presence of Antifungal Agents
    Koeck, Robin
    Eissing, Lea C.
    Boschin, Matthias G.
    Ellger, Bjoern
    Horn, Dagmar
    Idelevich, Evgeny A.
    Becker, Karsten
    JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (11) : 3683 - 3687
  • [26] CONTROLLED EVALUATION OF 5-MILLILITERS VERSUS 10-MILLILITERS OF BLOOD CULTURED IN AEROBIC BACT/ALERT BLOOD CULTURE BOTTLES
    WEINSTEIN, MP
    MIRRETT, S
    WILSON, ML
    REIMER, LG
    RELLER, LB
    JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (09) : 2103 - 2106
  • [27] Multicenter clinical comparison of Resin-containing bottles with standard aerobic and anaerobic bottles for culture of microorganisms from blood
    Lelievre, H
    Gimenez, M
    Vandenesch, F
    Reinhardt, A
    Lenhardt, D
    Just, HM
    Pau, M
    Ausina, V
    Etienne, J
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1997, 16 (09) : 669 - 674
  • [28] Evaluating the Utility of an Increased Platelet Inoculum in BACT/Alert Aerobic Culture Bottles
    Su, L.
    Bravo, M.
    Vanderpool, S. K.
    Souza, S. E.
    Kamel, H.
    Tomasulo, P. A.
    TRANSFUSION, 2010, 50 : 196A - 196A
  • [29] Controlled clinical comparison of BacT/ALERT standard aerobic and standard anaerobic blood culture bottles inoculated directly or after transport in sodium polyanethol sulfonate tubes
    Pien, Brian C.
    Mirrett, Stanley
    Crews, Betty R.
    Reller, L. Barth
    Woods, Christopher W.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (04) : 1357 - 1359
  • [30] Effect of Blood Volume in Standard Anaerobic Blood Culture Bottles of the BacT/ALERT 3D System Used for the Detection of Pathogens and Time to Detection
    Kim, Seong Chun
    Kim, Sunjoo
    Lee, Dong-Hyun
    Choi, Sae-Rom
    Kim, Jeong-Sook
    PLOS ONE, 2015, 10 (02):