Comparison of the BacT/Alert PF pediatric FAN blood culture bottle with the standard pediatric blood culture bottle, the Pedi-BacT

被引:16
|
作者
Krisher, KK
Gibb, P
Corbett, S
Church, D
机构
[1] Childrens Med Ctr, Clin Microbiol Lab, Dallas, TX 75235 USA
[2] Calgary Lab Serv, Calgary, AB TC3 0J5, Canada
关键词
D O I
10.1128/JCM.39.8.2880-2883.2001
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The performance of the BacT/Alert PF (Organon-Teknika Corp., Durham, N.C.), a new nonvented pediatric FAN blood culture bottle, was compared to that of the original pediatric bottle, the Pedi-BacT, with matched aerobic cultures obtained from two separate facilities. A total of 244 clinically significant isolates were recovered from 4,015 compliant pairs. Among the positive cultures, 170 (70%) isolates were detected in both the BacT/Alert PF and the Pedi-BacT bottles, while 47 (19%) isolates were recovered in the BacT/Alert PIT bottle only and 27 (11%) isolates were recovered in the Pedi-BacT bottle only. Although isolation of specific microorganisms was comparable for the two bottles, the total number of organisms recovered by the BacT/Alert PF was greater than that by the Pedi-BacT (P = 0.0272). In addition, more organisms were recovered by the BacT/Alert PF bottle from the blood of patients receiving antimicrobial therapy (P = 0.0180). Overall time to detection was similar for the two bottles; however, a significantly decreased mean time to detection was recorded for yeast from the BacT/Alert PF bottle (22.9 h; P = 0.0001) and staphylococci from the Pedi-BacT bottle (22.5 h; P = 0.0056). One false-negative culture and five false-positive cultures occurred with the Pedi-BacT bottle, compared to one false-positive culture with the BacT/Alert PF bottle. The BacT/Alert PF bottle is a reliable blood culture bottle for pediatric blood culture specimens and may offer improved recovery of microbes from patients on antimicrobial therapy. The use of the nonvented bottle will both facilitate bottle processing and decrease expenditures for materials due to the elimination of the venting needles required for the original vented bottles.
引用
收藏
页码:2880 / 2883
页数:4
相关论文
共 50 条
  • [21] Time to Detection with BacT/Alert FA Plus Compared to BacT/Alert FA Blood Culture Media
    A. Nutman
    S. Fisher Even-Tsur
    G. Shapiro
    T. Braun
    D. Schwartz
    Y. Carmeli
    European Journal of Clinical Microbiology & Infectious Diseases, 2016, 35 : 1469 - 1473
  • [22] CONTROLLED EVALUATION OF BACT ALERT STANDARD AEROBIC AND FAN AEROBIC BLOOD CULTURE BOTTLES FOR DETECTION OF BACTEREMIA AND FUNGEMIA
    WEINSTEIN, MP
    MIRRETT, S
    REIMER, LG
    WILSON, ML
    SMITHELEKES, S
    CHUARD, CR
    JOHO, KL
    RELLER, LB
    JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (04) : 978 - 981
  • [23] CONTROLLED EVALUATION OF BACT ALERT STANDARD ANAEROBIC AND FAN ANAEROBIC BLOOD CULTURE BOTTLES FOR THE DETECTION OF BACTEREMIA AND FUNGEMIA
    WILSON, ML
    WEINSTEIN, MP
    MIRRETT, S
    REIMER, LG
    FELDMAN, RJ
    CHUARD, CR
    RELLER, LB
    JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (09) : 2265 - 2270
  • [24] Accuracy of BacT/Alert Virtuo for Measuring Blood Volume for Blood Culture
    Lee, Seungjun
    Kim, Sunjoo
    ANNALS OF LABORATORY MEDICINE, 2019, 39 (06) : 590 - 592
  • [25] Reassessment of the incubation time in a controlled clinical comparison of the BacT/Alert aerobic FAN bottle and standard anaerobic bottle used aerobically for the detection of bloodstream infections
    Cornish, N
    Kirkley, BA
    Easley, KA
    Washington, JA
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1998, 32 (01) : 1 - 7
  • [26] Comparison of BacT/Alert blood culture bottles with lytic media for culture of peritoneal dialysis fluid
    Wust, J
    vonGraevenitz, A
    INFECTION, 1995, 23 (06) : 378 - 379
  • [27] Comparison of the BacT/Alert FAN aerobic and the Difco ESP 80A aerobic bottles for pediatric blood cultures
    WelbySellenriek, PL
    Keller, DS
    Ferrett, RJ
    Storch, GA
    JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (05) : 1166 - 1171
  • [28] Clinical importance of increased sensitivity of BacT/Alert FAN aerobic and anaerobic blood culture bottles
    McDonald, LC
    Fune, J
    Gaido, LB
    Weinstein, MP
    Reimer, LG
    Flynn, TM
    Wilson, ML
    Mirrett, S
    Reller, LB
    JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (09) : 2180 - 2184
  • [29] Controlled comparison of BacT/ALERT FAN aerobic medium and BACTEC fungal blood culture medium for detection of fungemia
    McDonald, LC
    Weinstein, MP
    Fune, J
    Mirrett, S
    Reimer, LG
    Reller, LB
    JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (02) : 622 - 624
  • [30] EVALUATION OF ROUTINE ANAEROBIC BLOOD CULTURES IN THE BACT/ALERT BLOOD CULTURE SYSTEM
    BANNISTER, ER
    WOODS, GL
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1995, 104 (03) : 279 - 282