Comparison of the BacT/Alert PF pediatric FAN blood culture bottle with the standard pediatric blood culture bottle, the Pedi-BacT

被引:16
|
作者
Krisher, KK
Gibb, P
Corbett, S
Church, D
机构
[1] Childrens Med Ctr, Clin Microbiol Lab, Dallas, TX 75235 USA
[2] Calgary Lab Serv, Calgary, AB TC3 0J5, Canada
关键词
D O I
10.1128/JCM.39.8.2880-2883.2001
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The performance of the BacT/Alert PF (Organon-Teknika Corp., Durham, N.C.), a new nonvented pediatric FAN blood culture bottle, was compared to that of the original pediatric bottle, the Pedi-BacT, with matched aerobic cultures obtained from two separate facilities. A total of 244 clinically significant isolates were recovered from 4,015 compliant pairs. Among the positive cultures, 170 (70%) isolates were detected in both the BacT/Alert PF and the Pedi-BacT bottles, while 47 (19%) isolates were recovered in the BacT/Alert PIT bottle only and 27 (11%) isolates were recovered in the Pedi-BacT bottle only. Although isolation of specific microorganisms was comparable for the two bottles, the total number of organisms recovered by the BacT/Alert PF was greater than that by the Pedi-BacT (P = 0.0272). In addition, more organisms were recovered by the BacT/Alert PF bottle from the blood of patients receiving antimicrobial therapy (P = 0.0180). Overall time to detection was similar for the two bottles; however, a significantly decreased mean time to detection was recorded for yeast from the BacT/Alert PF bottle (22.9 h; P = 0.0001) and staphylococci from the Pedi-BacT bottle (22.5 h; P = 0.0056). One false-negative culture and five false-positive cultures occurred with the Pedi-BacT bottle, compared to one false-positive culture with the BacT/Alert PF bottle. The BacT/Alert PF bottle is a reliable blood culture bottle for pediatric blood culture specimens and may offer improved recovery of microbes from patients on antimicrobial therapy. The use of the nonvented bottle will both facilitate bottle processing and decrease expenditures for materials due to the elimination of the venting needles required for the original vented bottles.
引用
收藏
页码:2880 / 2883
页数:4
相关论文
共 50 条
  • [31] Clinical comparison of the Bactec Mycosis IC/F, BacT/Alert FA, and BacT/Alert FN blood culture vials for the detection of candidemia
    Ericson, Eva-Lena
    Klingspor, Lena
    Ullberg, Mans
    Ozenci, Volkan
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2012, 73 (02) : 153 - 156
  • [32] Three days of incubation may be sufficient for routine blood cultures with BacT/Alert FAN blood culture bottles
    Bourbeau, PP
    Pohlman, JK
    JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (06) : 2079 - 2082
  • [33] Controlled Clinical Comparison of New Pediatric Medium with Adsorbent Polymeric Beads (PF Plus) versus Charcoal-Containing PF Medium in the BacT/Alert Blood Culture System
    Doern, Christopher D.
    Mirrett, Stanley
    Halstead, Diane
    Abid, Joan
    Okada, Pamela
    Reller, L. Barth
    JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (06) : 1898 - 1900
  • [34] Superior Sensitivity and Decreased Time to Detection with the Bactec Peds Plus/F System Compared to the BacT/Alert Pediatric FAN Blood Culture System
    Sullivan, K. V.
    Turner, N. N.
    Lancaster, D. P.
    Shah, A. R.
    Chandler, L. J.
    Friedman, D. F.
    Blecker-Shelly, D. L.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (12) : 4083 - 4086
  • [35] Growth and maturation of Plasmodium falciparum in BacT Alert blood culture system
    McCarthy, KM
    Frean, J
    Loakes, J
    Liebowitz, LD
    TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 1999, 93 (03) : 272 - 274
  • [36] COMPARISON OF BACTEC-9240 AND BACT/ALERT BLOOD CULTURE SYSTEMS IN AN ADULT HOSPITAL
    SMITH, JA
    BRYCE, EA
    NGUIYEN, JH
    ROBERTS, FJ
    JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (07) : 1905 - 1908
  • [37] EVALUATION OF THE AUTOMATED BACT-ALERT SYSTEM FOR PEDIATRIC BLOOD CULTURING
    PICKETT, DA
    WELCH, DF
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1995, 103 (03) : 320 - 323
  • [38] Use of the BacT/Alert blood culture system for culture of sterile body fluids other than blood
    Bourbeau, P
    Riley, J
    Heiter, BJ
    Master, R
    Young, C
    Pierson, C
    JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (11) : 3273 - 3277
  • [39] Comparison of 'time to detection' values between BacT/ALERT VIRTUO and BacT/ALERT 3D instruments for clinical blood culture samples
    Congestri, Francesco
    Pedna, Maria Federica
    Fantini, Michela
    Samuelli, Michela
    Schiavone, Pasqua
    Torri, Arianna
    Bertini, Stefania
    Sambri, Vittorio
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2017, 62 : 1 - 5
  • [40] Clinical evaluation of the BacT/Alert and isolator aerobic blood culture systems
    Engler, HD
    Fahle, GA
    Gill, VJ
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1996, 105 (06) : 774 - 781