Tube Current Modulation Between Single- and Dual-Energy CT With a Second-Generation Dual-Source Scanner: Radiation Dose and Image Quality

被引:6
|
作者
Matsubara, Kosuke [1 ]
Takata, Tadanori [2 ]
Kobayashi, Masanao [3 ]
Kobayashi, Satoshi [1 ]
Koshida, Kichiro [1 ]
Gabata, Toshifumi [4 ]
机构
[1] Kanazawa Univ, Fac Hlth Sci, Inst Med Pharmaceut & Hlth Sci, Dept Quantum Med Technol, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[2] Kanazawa Univ Hosp, Dept Radiol Technol, Kanazawa, Ishikawa, Japan
[3] Fujita Hlth Univ, Sch Hlth Sci, Fac Radiol Technol, Toyoake, Aichi, Japan
[4] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Dept Radiol, Fac Med, Kanazawa, Ishikawa, Japan
关键词
dosimetry; dual-energy CT; image noise; radiation dose; tube current modulation; AUTOMATIC EXPOSURE CONTROL; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; PATIENT SIZE; ABDOMINAL CT; ITERATIVE RECONSTRUCTION; STONE COMPOSITION; BLOOD-VOLUME; ANGIOGRAPHY; REDUCTION;
D O I
10.2214/AJR.15.15404
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare the effects of tube current modulation between single- and dual-energy CT with a second-generation dual-source scanner. MATERIALS AND METHODS. Custom-made elliptic polymethylmethacrylate phantoms for slim and large patients were used. Absorbed radiation dose at the central point of the phantoms was measured with a solid-state detector while the phantoms were scanned in single-energy (120 kV) and dual-energy (100/Sn140, 80/Sn140, and 140/80 kV) modes with a second-generation dual-source CT scanner. Tube current modulation was activated in both modes, and quality reference tube current-time settings of 150, 300, 450, and 600 mAs were selected. Scanning was performed three times under the same conditions, and image noise was evaluated by measuring the SD of CT numbers in four separate regions of three adjacent images of the phantoms. RESULTS. Absorbed dose increased and image noise decreased with an increase in quality reference tube current-time setting when the slim phantom was scanned. For the large phantom, the radiation dose and noise level reached a plateau above quality reference tube current-time settings of 300 mAs for 100/Sn140 kV and 450 mAs for 120 kV. The radiation dose was small and the noise level was large with 80/Sn140 kV compared with that obtained with 120 and 100/Sn140 kV at all quality reference tube current-time settings. CONCLUSION. When a large phantom is scanned with 100/Sn140 kV, exposure demand for tube current modulation exceeds system limits at a lower quality reference tube current-time setting than for scanning 120 kV.
引用
收藏
页码:354 / 361
页数:8
相关论文
共 50 条
  • [41] Dual-Energy CT Perfusion During Pharmacologic Stress for the Assessment of Myocardial Perfusion Defects Using a Second-Generation Dual-Source CT: A Comparison With Cardiac Magnetic Resonance Imaging
    Kim, Sung Mok
    Chang, Sung-A
    Shin, Wonseon
    Choe, Yeon Hyeon
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (01) : 44 - 52
  • [42] Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repair
    Buffa, Vitaliano
    Solazzo, Antonio
    D'Auria, Valeria
    Del Prete, Alessandra
    Vallone, Andrea
    Luzietti, Monica
    Madau, Manuela
    Grassi, Roberto
    Miele, Vittorio
    RADIOLOGIA MEDICA, 2014, 119 (12): : 934 - 941
  • [43] Dual-source dual-energy CT angiography with virtual non-enhanced images and iodine map for active gastrointestinal bleeding: Image quality, radiation dose and diagnostic performance
    Sun, Hao
    Hou, Xin-Yi
    Xue, Hua-Dan
    Li, Xiao-Guang
    Jin, Zheng-Yu
    Qian, Jia-Ming
    Yu, Jian-Chun
    Zhu, Hua-Dong
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (05) : 884 - 891
  • [44] Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repair
    Vitaliano Buffa
    Antonio Solazzo
    Valeria D’Auria
    Alessandra Del Prete
    Andrea Vallone
    Monica Luzietti
    Manuela Madau
    Roberto Grassi
    Vittorio Miele
    La radiologia medica, 2014, 119 : 934 - 941
  • [45] Impact of the automatic tube current modulation (ATCM) system on virtual monoenergetic image quality for dual-source CT: A phantom study
    Dabli, D.
    Durand, Quentin
    Frandon, J.
    de Oliveira, Fabien
    Pastor, Maxime
    Beregi, J. P.
    Greffier, J.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 109
  • [46] Image quality and absorbed dose comparison of single- and dual-source cone-beam computed tomography
    Miura, Hideharu
    Ozawa, Shuichi
    Okazue, Toshiya
    Kawakubo, Atsushi
    Yamada, Kiyoshi
    Nagata, Yasushi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (03): : 360 - 366
  • [47] Single-source chest-abdomen-pelvis cancer staging on a third generation dual-source CT system: comparison of automated tube potential selection to second generation dual-source CT
    Clara Park
    Tatjana Gruber-Rouh
    Doris Leithner
    Amelie Zierden
    Mortiz H. Albrecht
    Julian L. Wichmann
    Boris Bodelle
    Mohamed Elsabaie
    Jan-Erik Scholtz
    Moritz Kaup
    Thomas J. Vogl
    Martin Beeres
    Cancer Imaging, 16
  • [48] Radiation dose and image quality of computed tomography of the supra-aortic arteries: A comparison between single-source and dual-source CT Scanners
    Saba, Luca
    di Martino, Michele
    Siotto, Paolo
    Anzidei, Michele
    Argiolas, Giovanni Maria
    Porcu, Michele
    Suri, Jasjit S.
    Wintermark, Max
    JOURNAL OF NEURORADIOLOGY, 2018, 45 (02) : 136 - 141
  • [49] Single-source chest-abdomen-pelvis cancer staging on a third generation dual-source CT system: comparison of automated tube potential selection to second generation dual-source CT
    Park, Clara
    Gruber-Rouh, Tatjana
    Leithner, Doris
    Zierden, Amelie
    Albrecht, Mortiz H.
    Wichmann, Julian L.
    Bodelle, Boris
    Elsabaie, Mohamed
    Scholtz, Jan-Erik
    Kaup, Moritz
    Vogl, Thomas J.
    Beeres, Martin
    CANCER IMAGING, 2016, 16 : 1 - 7
  • [50] Dose and image quality at CT pulmonary angiography—comparison of first and second generation dual-energy CT and 64-slice CT
    Ralf W. Bauer
    Sebastian Kramer
    Matthias Renker
    Boris Schell
    Maya Christina Larson
    Martin Beeres
    Thomas Lehnert
    Volkmar Jacobi
    Thomas J. Vogl
    Josef Matthias Kerl
    European Radiology, 2011, 21 : 2139 - 2147