Tube Current Modulation Between Single- and Dual-Energy CT With a Second-Generation Dual-Source Scanner: Radiation Dose and Image Quality

被引:6
|
作者
Matsubara, Kosuke [1 ]
Takata, Tadanori [2 ]
Kobayashi, Masanao [3 ]
Kobayashi, Satoshi [1 ]
Koshida, Kichiro [1 ]
Gabata, Toshifumi [4 ]
机构
[1] Kanazawa Univ, Fac Hlth Sci, Inst Med Pharmaceut & Hlth Sci, Dept Quantum Med Technol, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[2] Kanazawa Univ Hosp, Dept Radiol Technol, Kanazawa, Ishikawa, Japan
[3] Fujita Hlth Univ, Sch Hlth Sci, Fac Radiol Technol, Toyoake, Aichi, Japan
[4] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Dept Radiol, Fac Med, Kanazawa, Ishikawa, Japan
关键词
dosimetry; dual-energy CT; image noise; radiation dose; tube current modulation; AUTOMATIC EXPOSURE CONTROL; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; PATIENT SIZE; ABDOMINAL CT; ITERATIVE RECONSTRUCTION; STONE COMPOSITION; BLOOD-VOLUME; ANGIOGRAPHY; REDUCTION;
D O I
10.2214/AJR.15.15404
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare the effects of tube current modulation between single- and dual-energy CT with a second-generation dual-source scanner. MATERIALS AND METHODS. Custom-made elliptic polymethylmethacrylate phantoms for slim and large patients were used. Absorbed radiation dose at the central point of the phantoms was measured with a solid-state detector while the phantoms were scanned in single-energy (120 kV) and dual-energy (100/Sn140, 80/Sn140, and 140/80 kV) modes with a second-generation dual-source CT scanner. Tube current modulation was activated in both modes, and quality reference tube current-time settings of 150, 300, 450, and 600 mAs were selected. Scanning was performed three times under the same conditions, and image noise was evaluated by measuring the SD of CT numbers in four separate regions of three adjacent images of the phantoms. RESULTS. Absorbed dose increased and image noise decreased with an increase in quality reference tube current-time setting when the slim phantom was scanned. For the large phantom, the radiation dose and noise level reached a plateau above quality reference tube current-time settings of 300 mAs for 100/Sn140 kV and 450 mAs for 120 kV. The radiation dose was small and the noise level was large with 80/Sn140 kV compared with that obtained with 120 and 100/Sn140 kV at all quality reference tube current-time settings. CONCLUSION. When a large phantom is scanned with 100/Sn140 kV, exposure demand for tube current modulation exceeds system limits at a lower quality reference tube current-time setting than for scanning 120 kV.
引用
收藏
页码:354 / 361
页数:8
相关论文
共 50 条
  • [31] Detecting Intracranial Hemorrhage Using Automatic Tube Current Modulation With Advanced Modeled Iterative Reconstruction in Unenhanced Head Single-and Dual-Energy Dual-Source CT
    Scholtz, Jan-Erik
    Wichmann, Julian L.
    Bennett, Dennis W.
    Leithner, Doris
    Bauer, Ralf W.
    Vogl, Thomas J.
    Bodelle, Boris
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (05) : 1089 - 1096
  • [32] Pre-operative Percutaneous Nephrolithotripsy Characterisation of Kidney Stones with Second-Generation Dual-Source Dual-Energy Computed Tomography
    Ali, D. K. Mella Mohd
    Mahmud, Mohd Hafizi
    Mohamad, Noor Shafini
    MALAYSIAN JOURNAL OF MEDICAL SCIENCES, 2020, 27 (05): : 43 - 52
  • [33] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Park, Eun-Ah
    Lee, Whal
    Kim, Kwang Woo
    Kim, Kwang Gi
    Thomas, Allmendinger
    Chung, Jin Wook
    Park, Jae Hyung
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (07): : 1775 - 1786
  • [34] Comparison of image quality and radiation dose between split-filter dual-energy images and single-energy images in single-source abdominal CT
    Euler, Andre
    Obmann, Markus M.
    Szucs-Farkas, Zsolt
    Mileto, Achille
    Zaehringer, Caroline
    Falkowski, Anna L.
    Winkel, David J.
    Marin, Daniele
    Stieltjes, Bram
    Krauss, Bernhard
    Schindera, Sebastian T.
    EUROPEAN RADIOLOGY, 2018, 28 (08) : 3405 - 3412
  • [35] Comparison of image quality and radiation dose between split-filter dual-energy images and single-energy images in single-source abdominal CT
    André Euler
    Markus M. Obmann
    Zsolt Szucs-Farkas
    Achille Mileto
    Caroline Zaehringer
    Anna L. Falkowski
    David J. Winkel
    Daniele Marin
    Bram Stieltjes
    Bernhard Krauss
    Sebastian T. Schindera
    European Radiology, 2018, 28 : 3405 - 3412
  • [36] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Eun-Ah Park
    Whal Lee
    Kwang Woo Kim
    Kwang Gi Kim
    Allmendinger Thomas
    Jin Wook Chung
    Jae Hyung Park
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1775 - 1786
  • [37] Assessment of the image quality and the radiation dose of the third generation of dual-source CT used for the diagnosis of coronary heart disease
    Xu, Feng
    Shi, Wei-shi
    Xu, Tian-tian
    Qiu, Li
    Ye, Zhen
    Li, Peng-qin
    Liu, Yan-xiao
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 125 : 288 - 288
  • [38] Dual-energy CT for routine imaging of the abdomen and pelvis: radiation dose and image quality
    Jeremy R. Wortman
    Jeffrey Y. Shyu
    Jeffrey Dileo
    Jennifer W. Uyeda
    Aaron D. Sodickson
    Emergency Radiology, 2020, 27 : 45 - 50
  • [39] Dual-energy CT for routine imaging of the abdomen and pelvis: radiation dose and image quality
    Wortman, Jeremy R.
    Shyu, Jeffrey Y.
    Dileo, Jeffrey
    Uyeda, Jennifer W.
    Sodickson, Aaron D.
    EMERGENCY RADIOLOGY, 2020, 27 (01) : 45 - 50
  • [40] Image Quality and Dose Comparison of Single-Energy CT (SECT) and Dual-Energy CT (DECT)
    Shayan, Ramin Ghasemi
    Oladghaffari, Maryam
    Sajjadian, Fakhrosadat
    Ghaziyani, Mona Fazel
    RADIOLOGY RESEARCH AND PRACTICE, 2020, 2020