Tube Current Modulation Between Single- and Dual-Energy CT With a Second-Generation Dual-Source Scanner: Radiation Dose and Image Quality

被引:6
|
作者
Matsubara, Kosuke [1 ]
Takata, Tadanori [2 ]
Kobayashi, Masanao [3 ]
Kobayashi, Satoshi [1 ]
Koshida, Kichiro [1 ]
Gabata, Toshifumi [4 ]
机构
[1] Kanazawa Univ, Fac Hlth Sci, Inst Med Pharmaceut & Hlth Sci, Dept Quantum Med Technol, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[2] Kanazawa Univ Hosp, Dept Radiol Technol, Kanazawa, Ishikawa, Japan
[3] Fujita Hlth Univ, Sch Hlth Sci, Fac Radiol Technol, Toyoake, Aichi, Japan
[4] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Dept Radiol, Fac Med, Kanazawa, Ishikawa, Japan
关键词
dosimetry; dual-energy CT; image noise; radiation dose; tube current modulation; AUTOMATIC EXPOSURE CONTROL; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; PATIENT SIZE; ABDOMINAL CT; ITERATIVE RECONSTRUCTION; STONE COMPOSITION; BLOOD-VOLUME; ANGIOGRAPHY; REDUCTION;
D O I
10.2214/AJR.15.15404
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare the effects of tube current modulation between single- and dual-energy CT with a second-generation dual-source scanner. MATERIALS AND METHODS. Custom-made elliptic polymethylmethacrylate phantoms for slim and large patients were used. Absorbed radiation dose at the central point of the phantoms was measured with a solid-state detector while the phantoms were scanned in single-energy (120 kV) and dual-energy (100/Sn140, 80/Sn140, and 140/80 kV) modes with a second-generation dual-source CT scanner. Tube current modulation was activated in both modes, and quality reference tube current-time settings of 150, 300, 450, and 600 mAs were selected. Scanning was performed three times under the same conditions, and image noise was evaluated by measuring the SD of CT numbers in four separate regions of three adjacent images of the phantoms. RESULTS. Absorbed dose increased and image noise decreased with an increase in quality reference tube current-time setting when the slim phantom was scanned. For the large phantom, the radiation dose and noise level reached a plateau above quality reference tube current-time settings of 300 mAs for 100/Sn140 kV and 450 mAs for 120 kV. The radiation dose was small and the noise level was large with 80/Sn140 kV compared with that obtained with 120 and 100/Sn140 kV at all quality reference tube current-time settings. CONCLUSION. When a large phantom is scanned with 100/Sn140 kV, exposure demand for tube current modulation exceeds system limits at a lower quality reference tube current-time setting than for scanning 120 kV.
引用
下载
收藏
页码:354 / 361
页数:8
相关论文
共 50 条
  • [21] Dose levels and image quality of second-generation 128-slice dual-source coronary CT angiography in clinical routine
    Julian L. Wichmann
    Xiaohan Hu
    Alexander Engler
    J. Matthias Kerl
    Martin Beeres
    Claudia Frellesen
    Wolfgang Luboldt
    Thomas J. Vogl
    Ralf W. Bauer
    Thomas Lehnert
    La radiologia medica, 2015, 120 : 1112 - 1121
  • [22] Dual-Source Dual-Energy CT in Submandibular Sialolithiasis: Reliability and Radiation Burden
    Pulickal, Geoiphy George
    Singh, Dinesh
    Lohan, Rahul
    Chawla, Ashish
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (06) : 1291 - 1296
  • [23] Comparison of Image Quality and Radiation Dose Between Single-Energy and Dual-Energy Images for the Brain With Stereotactic Frames on Dual-Energy Cerebral CT
    Zhao, Xiaojing
    Chao, Wang
    Shan, Yi
    Li, Jingkai
    Zhao, Cheng
    Zhang, Miao
    Lu, Jie
    FRONTIERS IN RADIOLOGY, 2022, 2
  • [24] The evaluation of myocardial infarction with dual-energy myocardial perfusion using second-generation dual-source CT: an experimental study in a pig model
    Zhao Ruiping
    Li Hongyu
    Lu Yaojun
    Sun Kai
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (16) : C124 - C124
  • [25] Evaluation of image quality and radiation dose of abdominal dual-energy CT
    Schmidt, David
    Soderberg, Marcus
    Nilsson, Mats
    Lindvall, Hakan
    Christoffersen, Christina
    Leander, Peter
    ACTA RADIOLOGICA, 2018, 59 (07) : 845 - 852
  • [26] Effects of Patient Size and Radiation Dose on Iodine Quanti fi cation in Dual-Source Dual-Energy CT
    Jiang, Xia
    Yang, Xiangyu
    Hintenlang, David E.
    White, Richard D.
    ACADEMIC RADIOLOGY, 2021, 28 (01) : 96 - 105
  • [27] Image quality of lung perfusion with photon-counting-detector CT: comparison with dual-source, dual-energy CT
    Remy-Jardin, Martine
    Guiffault, Lucas
    Oufriche, Idir
    Duhamel, Alain
    Flohr, Thomas
    Schmidt, Bernhard
    Remy, Jacques
    EUROPEAN RADIOLOGY, 2024, : 7831 - 7844
  • [28] Low-dose dual-energy CT for stone characterization: a systematic comparison of two generations of split-filter single-source and dual-source dual-energy CT
    Nakhostin, Dominik
    Sartoretti, Thomas
    Eberhard, Matthias
    Krauss, Bernhard
    Mueller, Daniel
    Alkadhi, Hatem
    Euler, Andre
    ABDOMINAL RADIOLOGY, 2021, 46 (05) : 2079 - 2089
  • [29] Low-dose dual-energy CT for stone characterization: a systematic comparison of two generations of split-filter single-source and dual-source dual-energy CT
    Dominik Nakhostin
    Thomas Sartoretti
    Matthias Eberhard
    Bernhard Krauss
    Daniel Müller
    Hatem Alkadhi
    André Euler
    Abdominal Radiology, 2021, 46 : 2079 - 2089
  • [30] Feasibility of Dose Optimization in a Second-Generation Dual-Source CT Scanner for a Manufacturer-Recommended Urolithiasis Protocol for Imaging Renal Stones
    Pansini, Michele
    Morsbach, Fabian
    Schubert, Tilman
    Hohmann, Joachim
    Kovacs, Balazs
    Szucs-Farkas, Zsolt
    Schindera, Sebastian T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (02) : 348 - 354