Impact of the automatic tube current modulation (ATCM) system on virtual monoenergetic image quality for dual-source CT: A phantom study

被引:2
|
作者
Dabli, D. [1 ,2 ,3 ]
Durand, Quentin [1 ,2 ]
Frandon, J. [1 ]
de Oliveira, Fabien [1 ]
Pastor, Maxime [1 ]
Beregi, J. P. [1 ]
Greffier, J. [1 ,2 ]
机构
[1] Montpellier Univ, Nimes Univ Hosp, Dept Med Imaging, IMAGINE UR UM 103, F-30029 Nimes, France
[2] Nimes Univ Hosp, Dept Med Phys, F-30029 Nimes 9, France
[3] Montpellier Univ, Nimes Univ Hosp, Dept Med Imaging, CHU Nimes,IMAGINE UR UM 103, Bd Prof Robert Debre, F-30029 Nimes 9, France
关键词
Dual-source CT scan; Dual-energy CT; Virtual monochromatic images; Automatic tube current modulation; Detectability; ITERATIVE RECONSTRUCTION ALGORITHM; ENERGY COMPUTED-TOMOGRAPHY; LIVER-LESIONS; IODINE QUANTIFICATION; MAGNETIC-RESONANCE; EXPOSURE CONTROL; DOSE REDUCTION; OPTIMIZATION; PERFORMANCE; ACCURACY;
D O I
10.1016/j.ejmp.2023.102574
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the impact of the automatic tube current modulation (ATCM) on virtual monoenergetic images (VMIs) quality in dual-source CT(DSCT).Materials and methods: Acquisitions were performed on DSCT using the Mercury phantom. The acquisition pa-rameters for an abdomen-pelvic examination with single-energy CT(SECT) and dual-energy CT(DECT) imaging were used. Acquisitions were performed for each imaging mode using fixed mAs and ATCM. The mAs value was set to obtain a volume CT dose index of 11 mGy in fixed mAs acquisitions. This value was used as the reference mAs in ATCM acquisitions. The noise power spectrum and task-based transfer function at 40,50,60 and 70 keV levels were computed on VMIs and SECT images. The detectability index (d ') was calculated for a lesion with an iodine concentration of 10 mg/mL.Results: The noise magnitude on VMIs was higher with the ATCM system than with fixed mAs for all energy levels and section diameters of 21,26 and 31 cm. The noise texture and spatial resolution were similar between the fixed mAs and ATCM acquisitions for both imaging modes. The d' values were lower for all energy levels with ATCM than with fixed mAs acquisitions for 21 and 26 cm diameters by-39.82 +/- 9.32%, similar at 31 cm diameter-4.13 +/- 0.24% and higher at 36 cm diameter 10.40 +/- 6.69%. It was higher on VMIs at all energy levels compared to SECT images.Conclusions: The ATCM system could be used with DECT imaging to optimize patient exposure without changing the noise texture and spatial resolution of VMIs compared to fixed mAs and SECT.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] The application of automatic tube current modulation (ATCM) on image quality and radiation dose at abdominal computed tomography (CT): A phantom study
    Wang, Qian
    Zhao, Xinming
    Song, Junfeng
    Guo, Ning
    Zhu, Ying
    Liu, Jianxin
    Qi, Weiwei
    Wu, Jing
    Liang, Yuan
    Feng, Shichao
    Hu, Mancang
    Zhou, Chunwu
    Wang, Xiaoying
    Hong, Nan
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (04) : 453 - 464
  • [2] A Novel Phantom to Evaluate Longitudinal and Angular Automatic Tube Current Modulation (ATCM) in CT
    Merzan, D.
    Bujila, R.
    Nowik, P.
    MEDICAL PHYSICS, 2015, 42 (06) : 3643 - 3643
  • [3] Effective dose and image quality evaluations of an automatic CT tube current modulation system with an anthropomorphic phantom
    Rampado, O.
    Marchisio, F.
    Izzo, A.
    Garelli, E.
    Bianchi, C. C.
    Gandini, G.
    Ropolo, R.
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (01) : 181 - 187
  • [4] Comparison of the spectral performance between two dual-source CT systems on low-energy virtual monoenergetic images: A phantom study
    Greffier, Joel
    Faby, Sebastian
    Pastor, Maxime
    Frandon, Julien
    Erath, Julien
    Beregi, Jean-Paul
    Dabli, Djamel
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 124
  • [5] Image Quality Analysis of Photon-Counting CT Compared with Dual-Source CT: A Phantom Study for Chest CT Examinations
    Deleu, Marine
    Maurice, Jean-Baptiste
    Devos, Laura
    Remy, Martine
    Dubus, Francois
    DIAGNOSTICS, 2023, 13 (07)
  • [6] Effect of Automatic Tube Current Modulation on Radiation Dose and Image Quality for Low Tube Voltage Multidetector Row CT Angiography: Phantom Study
    Schindera, Sebastian T.
    Nelson, Rendon C.
    Yoshizumi, Terry
    Toncheva, Greta
    Nguyen, Giao
    DeLong, David M.
    Szucs-Farkas, Zsolt
    ACADEMIC RADIOLOGY, 2009, 16 (08) : 997 - 1002
  • [7] Impact of an advanced image-based monoenergetic reconstruction algorithm on coronary stent visualization using third generation dual-source dual-energy CT: a phantom study
    Mangold, Stefanie
    Cannao, Paola M.
    Schoepf, U. Joseph
    Wichmann, Julian L.
    Canstein, Christian
    Fuller, Stephen R.
    Muscogiuri, Giuseppe
    Varga-Szemes, Akos
    Nikolaou, Konstantin
    De Cecco, Carlo N.
    EUROPEAN RADIOLOGY, 2016, 26 (06) : 1871 - 1878
  • [8] Impact of an advanced image-based monoenergetic reconstruction algorithm on coronary stent visualization using third generation dual-source dual-energy CT: a phantom study
    Stefanie Mangold
    Paola M. Cannaó
    U. Joseph Schoepf
    Julian L. Wichmann
    Christian Canstein
    Stephen R. Fuller
    Giuseppe Muscogiuri
    Akos Varga-Szemes
    Konstantin Nikolaou
    Carlo N. De Cecco
    European Radiology, 2016, 26 : 1871 - 1878
  • [9] Radiation dose estimates in retrospectively ECG-gated dual-source CT coronary angiography with different tube current modulation algorithms: a phantom study
    Martini, C.
    Palumbo, A.
    Maffei, Erica E.
    Sacco, C.
    Mollet, N.
    Dijkshoorn, M.
    Weustink, A.
    Cademartiri, F.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S65 - S65
  • [10] Tube Current Modulation Between Single- and Dual-Energy CT With a Second-Generation Dual-Source Scanner: Radiation Dose and Image Quality
    Matsubara, Kosuke
    Takata, Tadanori
    Kobayashi, Masanao
    Kobayashi, Satoshi
    Koshida, Kichiro
    Gabata, Toshifumi
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (02) : 354 - 361