Student learning performance and indoor environmental quality (IEQ) in air-conditioned university teaching rooms

被引:145
|
作者
Lee, M. C. [2 ]
Mui, K. W. [1 ]
Wong, L. T. [1 ]
Chan, W. Y. [1 ]
Lee, E. W. M. [3 ]
Cheung, C. T. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
[2] Natl Taichung Inst Technol, Dept Interior Design, Taichung, Taiwan
[3] City Univ Hong Kong, Dept Bldg & Construct, Hong Kong, Hong Kong, Peoples R China
关键词
Indoor Environmental Quality (IEQ); Learning performance; Classroom and lecture hall; Subjective and objective measurement; NOISE-LEVELS; ACCEPTABILITY; COMFORT; MODEL;
D O I
10.1016/j.buildenv.2011.10.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigates the relationship between Indoor Environmental Quality (IEQ) and learning performance in air-conditioned university teaching rooms via subjective assessment and objective measurement. Together with the data of air temperature, relative humidity, air speed, mean radiant temperature, CO2 concentration, equivalent sound pressure level, horizontal illumination level, occupant activity and clothing insulation level measured in four classrooms and four large lecture halls, self-reported learning performance (in calculating, reading, understanding and typing) and perceived IEQ are evaluated. The results show strong associations of the overall IEQ votes with the environmental parameters. While thermal comfort, indoor air quality and visual environment are of comparable importance, aural environment is the major determining factor. The study also reveals that all IEQ complaints have similar impact on learning performance and there is a good correlation between learning performance and the number of complaints. To aid design needs, empirical expressions that approximate the impact of unsatisfactory IEQ on learning performance loss are proposed. (C) 2011 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:238 / 244
页数:7
相关论文
共 50 条
  • [1] An energy performance assessment for indoor environmental quality (IEQ) acceptance in air-conditioned offices
    Wong, L. T.
    Mui, K. W.
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (05) : 1362 - 1367
  • [2] Indoor Environmental Quality Benchmarks for Air-conditioned Offices in the Subtropics
    Mui, K. W.
    Wong, L. T.
    Hui, P. S.
    INDOOR AND BUILT ENVIRONMENT, 2009, 18 (02) : 123 - 129
  • [3] Wall/roof thermal performance differences between air-conditioned and non air-conditioned rooms
    Barrios, G.
    Huelsz, G.
    Rechtman, R.
    Rojas, J.
    ENERGY AND BUILDINGS, 2011, 43 (01) : 219 - 223
  • [4] Indoor air quality and energy performance of air-conditioned office buildings in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, KW
    INDOOR AIR, 2003, 13 (04) : 315 - 331
  • [5] Screening for indoor air quality of air-conditioned off ices
    Wong, L. T.
    Mui, K. W.
    Hui, P. S.
    INDOOR AND BUILT ENVIRONMENT, 2007, 16 (05) : 438 - 443
  • [6] Diagnostics of Unsatisfactory Indoor Air Quality in Air-Conditioned Workplaces
    Mui, K. W.
    Hui, P. S.
    Wong, L. T.
    INDOOR AND BUILT ENVIRONMENT, 2011, 20 (03) : 313 - 320
  • [7] Indoor suspended particulates distribution in an air-conditioned teaching building
    Huang, YC
    Yang, SH
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1807 - 1810
  • [8] Ventilation and Indoor Thermal Environment in Air-Conditioned Rooms with Open Windows in Winter
    Okamura, Akira
    Lee, Sihwan
    INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES (IAQ 2020), PT 1, 2021,
  • [9] Adaptive PID Control of Indoor Air Quality for an Air-conditioned Room
    Gu, Xiaosong
    Li, Heng
    Zhao, Litie
    Wang, Hanqing
    INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION, VOL 1, PROCEEDINGS, 2008, : 289 - +
  • [10] Fungi - an indoor air quality assessment parameter for air-conditioned offices
    Mui, K. W.
    Chan, W. Y.
    Wong, L. T.
    Hui, P. S.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2007, 28 (03): : 265 - 274