Student learning performance and indoor environmental quality (IEQ) in air-conditioned university teaching rooms

被引:145
|
作者
Lee, M. C. [2 ]
Mui, K. W. [1 ]
Wong, L. T. [1 ]
Chan, W. Y. [1 ]
Lee, E. W. M. [3 ]
Cheung, C. T. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
[2] Natl Taichung Inst Technol, Dept Interior Design, Taichung, Taiwan
[3] City Univ Hong Kong, Dept Bldg & Construct, Hong Kong, Hong Kong, Peoples R China
关键词
Indoor Environmental Quality (IEQ); Learning performance; Classroom and lecture hall; Subjective and objective measurement; NOISE-LEVELS; ACCEPTABILITY; COMFORT; MODEL;
D O I
10.1016/j.buildenv.2011.10.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigates the relationship between Indoor Environmental Quality (IEQ) and learning performance in air-conditioned university teaching rooms via subjective assessment and objective measurement. Together with the data of air temperature, relative humidity, air speed, mean radiant temperature, CO2 concentration, equivalent sound pressure level, horizontal illumination level, occupant activity and clothing insulation level measured in four classrooms and four large lecture halls, self-reported learning performance (in calculating, reading, understanding and typing) and perceived IEQ are evaluated. The results show strong associations of the overall IEQ votes with the environmental parameters. While thermal comfort, indoor air quality and visual environment are of comparable importance, aural environment is the major determining factor. The study also reveals that all IEQ complaints have similar impact on learning performance and there is a good correlation between learning performance and the number of complaints. To aid design needs, empirical expressions that approximate the impact of unsatisfactory IEQ on learning performance loss are proposed. (C) 2011 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:238 / 244
页数:7
相关论文
共 50 条
  • [21] Indoor air quality in an air-conditioned building in new Delhi and its relationship to ambient air quality
    Prasad, RK
    Uma, R
    Kansal, A
    Gupta, S
    Kumar, P
    Saksena, S
    INDOOR AND BUILT ENVIRONMENT, 2002, 11 (06) : 334 - 339
  • [22] Influence of vertical greenery systems and green roofs on the indoor operative temperature of air-conditioned rooms
    Hao, Xiaoli
    Xing, Qingwei
    Long, Pinhan
    Lin, Yaolin
    Hu, Jinhua
    Tan, Hang
    JOURNAL OF BUILDING ENGINEERING, 2020, 31
  • [23] Assessment of indoor air quality in air-conditioned small business units with no mechanical ventilation
    Sankaran, Gayatri
    Tan, Sze Tat
    Shen, Joanna
    Gutierrez, Ramona
    Ng, Lee Ching
    Sim, Shuzhen
    ATMOSPHERIC ENVIRONMENT, 2023, 299
  • [24] Influence of indoor air quality (IAQ) objectives on air-conditioned offices in Hong Kong
    Pui-Shan Hui
    Kwok-Wai Mui
    Ling-Tim Wong
    Environmental Monitoring and Assessment, 2008, 144 : 315 - 322
  • [25] An implementation choice of assessment parameters for indoor air quality (IAQ) in air-conditioned offices
    Wong, L. T.
    Mui, K. W.
    Hui, P. S.
    Chan, W-Y.
    FACILITIES, 2009, 27 (5-6) : 202 - 210
  • [26] Influence of indoor air quality (IAQ) objectives on air-conditioned offices in Hong Kong
    Hui, Pui-Shan
    Mui, Kwok-Wai
    Wong, Ling-Tim
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2008, 144 (1-3) : 315 - 322
  • [27] Feasibility study of an express assessment protocol for the indoor air quality of air-conditioned offices
    Hui, P. S.
    Wong, L. T.
    Mui, K. W.
    INDOOR AND BUILT ENVIRONMENT, 2006, 15 (04) : 373 - 378
  • [28] Energy impact of indoor environmental policy for air-conditioned offices of Hong Kong
    Wong, L. T.
    Mui, K. W.
    Shi, K. L.
    ENERGY POLICY, 2008, 36 (02) : 714 - 721
  • [29] EFFECT OF SPRING GRASS FIRES ON INDOOR AIR QUALITY IN AIR-CONDITIONED OFFICE BUILDING
    Pauraite, J.
    Garbariene, I.
    Minderyte, A.
    Dudoitis, V.
    Mainelis, G.
    Davuliene, L.
    Uoginte, I.
    Plauskaite, K.
    Bycenkiene, S.
    LITHUANIAN JOURNAL OF PHYSICS, 2021, 61 (03): : 191 - 204
  • [30] Evaluation of the neutral criterion of indoor air quality for air-conditioned offices in subtropical climates
    Mui, K. W.
    Wong, L. T.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2007, 28 (01): : 23 - 33