Wall/roof thermal performance differences between air-conditioned and non air-conditioned rooms

被引:39
|
作者
Barrios, G. [1 ]
Huelsz, G. [1 ]
Rechtman, R. [1 ]
Rojas, J. [1 ]
机构
[1] Univ Nacl Autonoma Mexico, Ctr Invest Energia, Temixco 62580, Mor, Mexico
关键词
Wall/roof thermal performance; Periodic outdoor conditions; Air conditioned; Non air-conditioned; WALLS THERMOPHYSICAL PROPERTIES; DECREMENT FACTOR; TIME-LAG; VALUES;
D O I
10.1016/j.enbuild.2010.09.015
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A one dimensional heat transfer model for periodic outdoor conditions is presented and used to evaluate the thermal performance of a monolayered and multilayered envelope wall/roof in an air-conditioned and in a non air-conditioned room Three materials are tested for a monolayered wall/roof high density concrete (HOC) aerated concrete (AeC) and expanded polystyrene foam (EPS) Three multilayered walls/roofs of width 0 10 m composed of a sheet of 0 02 m of EPS and the rest of HOC are considered The EPS can be on the outside middle or inside of the wall/roof The main conclusion is that an appropriate wall/roof for an air-conditioned room may not be suitable for a non air-conditioned one For the monolayered wall/roof and conditions under study it is found that in an air-conditioned room the most important physical property of the wall/roof is its thermal conductivity which has to be as small as possible while for the non air-conditioned room the most important physical property is the thermal diffusivity which also has to be as small as possible In this case the position of the insulation in a multilayered wall/roof is important (C) 2010 Elsevier B V All rights reserved
引用
收藏
页码:219 / 223
页数:5
相关论文
共 50 条
  • [1] Envelope wall/roof thermal performance parameters for non air-conditioned buildings
    Barrios, G.
    Huelsz, G.
    Rojas, J.
    Ochoa, J. M.
    Marincic, I.
    [J]. ENERGY AND BUILDINGS, 2012, 50 : 120 - 127
  • [2] Thermal performance of envelope wall/roofs of intermittent air-conditioned rooms
    Barrios, G.
    Huelsz, G.
    Rojas, J.
    [J]. APPLIED THERMAL ENGINEERING, 2012, 40 : 1 - 7
  • [3] Thermal performance of domed roof in air-conditioned spaces
    Reda, Ibrahim
    AbdelMessih, Raouf N.
    Steit, Mohamed
    Mina, Ehab M.
    [J]. Energy and Built Environment, 2024, 5 (02): : 270 - 287
  • [4] AIR MOVEMENTS IN ILLUMINATED AND AIR-CONDITIONED ROOMS
    SOLLNER, G
    [J]. LICHTTECHNIK, 1970, 22 (01): : 17 - &
  • [5] HEAT BALANCE IN AIR-CONDITIONED ROOMS
    HANSEN, E
    MADSEN, TL
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1972, 16 (01) : 27 - &
  • [6] TEMPERATURE DISTRIBUTIONS IN AIR-CONDITIONED ROOMS
    PALLIER, JM
    YEZOU, R
    BRAU, J
    [J]. APPLIED ENERGY, 1983, 14 (01) : 49 - 64
  • [7] DISINFECTING AIR-CONDITIONED AIR
    不详
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 1962, (5288): : 1357 - +
  • [8] MEASUREMENT OF SMALL AIR VELOCITIES IN AIR-CONDITIONED ROOMS.
    Gasser, R.
    [J]. Sulzer Technical Review, 1974, 56 (02): : 105 - 114
  • [9] Air-conditioned health
    Yeeles, Adam
    [J]. NATURE CLIMATE CHANGE, 2018, 8 (08) : 662 - 662
  • [10] AIR-CONDITIONED HANDPIECE
    KILLILEA, JF
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1945, 32 (15): : 966 - 975