Thermal performance of envelope wall/roofs of intermittent air-conditioned rooms

被引:41
|
作者
Barrios, G. [1 ]
Huelsz, G. [1 ]
Rojas, J. [1 ]
机构
[1] Univ Nacl Autonoma Mexico, Ctr Invest & Energia, Temixco 62580, Morelos, Mexico
关键词
Wall/roof thermal performance; Intermittent air-conditioned; Numerical simulations; MULTILAYER WALLS; BUILDING WALLS; FLAT ROOFS; TIME-LAG; VALUES;
D O I
10.1016/j.applthermaleng.2012.01.051
中图分类号
O414.1 [热力学];
学科分类号
摘要
The thermal performance of six wall/roof configurations in an intermittent air-conditioned room, in a climate where the outdoor temperature or the sol air temperature swing crosses the thermal comfort zone, was numerically evaluated. The intermittent air-conditioning system operates heating or cooling. When operating for cooling it is turned on when the indoor temperature is greater than the upper comfort temperature and when operating for heating it is turned on if the indoor temperature is smaller than the lower comfort temperature: otherwise it remains off. A one dimensional heat transfer model with periodic outdoor conditions was considered. The parameters used to evaluate the configurations are the energy for the on-periods and a thermal index during the off-periods. For comparison purposes, the wall/roof configurations were also evaluated in an air-conditioned room where the temperature was kept constant full time. The results show that the thermal evaluation of a wall/roof must be done taking into account the operation condition of the air-conditioning system. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [1] Wall/roof thermal performance differences between air-conditioned and non air-conditioned rooms
    Barrios, G.
    Huelsz, G.
    Rechtman, R.
    Rojas, J.
    [J]. ENERGY AND BUILDINGS, 2011, 43 (01) : 219 - 223
  • [2] Envelope wall/roof thermal performance parameters for non air-conditioned buildings
    Barrios, G.
    Huelsz, G.
    Rojas, J.
    Ochoa, J. M.
    Marincic, I.
    [J]. ENERGY AND BUILDINGS, 2012, 50 : 120 - 127
  • [3] Thermal performance of non air-conditioned buildings with vaulted roofs in comparison with flat roofs
    Tang, RS
    Meir, IA
    Wu, T
    [J]. BUILDING AND ENVIRONMENT, 2006, 41 (03) : 268 - 276
  • [4] AIR MOVEMENTS IN ILLUMINATED AND AIR-CONDITIONED ROOMS
    SOLLNER, G
    [J]. LICHTTECHNIK, 1970, 22 (01): : 17 - &
  • [5] HEAT BALANCE IN AIR-CONDITIONED ROOMS
    HANSEN, E
    MADSEN, TL
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1972, 16 (01) : 27 - &
  • [6] TEMPERATURE DISTRIBUTIONS IN AIR-CONDITIONED ROOMS
    PALLIER, JM
    YEZOU, R
    BRAU, J
    [J]. APPLIED ENERGY, 1983, 14 (01) : 49 - 64
  • [7] Thermal and Energy Performance of Pitch and Wall Insulation for Air-Conditioned Buildings in Malaysia
    Halim, Noor Hafizah Abdul
    Zakaria, Nor Zaini
    Ahmed, Azni Zain
    [J]. SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT, PTS 1-3, 2012, 209-211 : 1766 - 1769
  • [8] Influence of vertical greenery systems and green roofs on the indoor operative temperature of air-conditioned rooms
    Hao, Xiaoli
    Xing, Qingwei
    Long, Pinhan
    Lin, Yaolin
    Hu, Jinhua
    Tan, Hang
    [J]. JOURNAL OF BUILDING ENGINEERING, 2020, 31
  • [9] Experimental Study on Thermal Performance of Externally Insulated Walls of Intermittent Air-Conditioned Rooms in Summer in Hot Summer and Cold Winter Region, China
    Ding, Yong
    Xu, Lu
    Li, Baizhan
    Liu, Xiaoqing
    [J]. ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2014, 2014
  • [10] Ventilation and Indoor Thermal Environment in Air-Conditioned Rooms with Open Windows in Winter
    Okamura, Akira
    Lee, Sihwan
    [J]. INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES (IAQ 2020), PT 1, 2021,