Thermal performance of non air-conditioned buildings with vaulted roofs in comparison with flat roofs

被引:35
|
作者
Tang, RS [1 ]
Meir, IA
Wu, T
机构
[1] Yunnan Normal Univ, Solar Energy Res Inst, Kunming 650092, Peoples R China
[2] Ben Gurion Univ Negev, Jacob Blaustein Inst Desert Res, Desert Architecture & Urban Planning Unit, IL-84990 Sede Boqer, Israel
关键词
vaulted roof; thermal performance; non air-conditioned buildings;
D O I
10.1016/j.buildenv.2005.01.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Vaulted or domed roofs have been frequently adopted by builders and architects throughout the Middle East and other hot dry areas. However, the thermal performance of such buildings under hot dry climatic conditions has rarely been quantitatively studied. In this paper, a detailed finite element model for the investigation of the thermal performance of non air-conditioned buildings with vaulted roofs (VR) is suggested based on two-dimensional unsteady heat transfer in such roofs and solar geometry. This model allows a comparison of the thermal performance of non air-conditioned buildings with a VR and a flat roof (FR) under different climatic conditions. Results obtained by numerical calculation show that, irrespective of building type the VRs are applied to, buildings with a VR have lower indoor temperatures as compared to those with a FR. The reason is that such roofs dissipate more heat than a FR does by convection and thermal radiation at night due to the enlarged curved surfaces. This implies that such roof forms are suitable for buildings located in hot dry regions but not for those located in hot humid areas, and reasonably explains why curved roofs have been extensively adopted by builders and architects in the hot dry areas in the past. However, with the decrease in the half rim angle of a VR, the difference of indoor thermal condition between a VR and a FR building becomes small and insignificant. Results also indicate that the indoor air temperature is slightly influenced by the half rim angle theta(0) and the orientation phi(v) of the VR. To be effective to create a favorable thermal condition inside buildings with a VR under hot dry climatic conditions, the half rim angle of a VR should be theta(0) > 50 degrees, instead of theta(0) < 50 degrees, which is the optimal half rim angle of a VR of air-conditioned buildings, as found by the present authors in a previous study. (C) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:268 / 276
页数:9
相关论文
共 50 条
  • [1] Thermal performance of envelope wall/roofs of intermittent air-conditioned rooms
    Barrios, G.
    Huelsz, G.
    Rojas, J.
    [J]. APPLIED THERMAL ENGINEERING, 2012, 40 : 1 - 7
  • [2] Thermal behavior of buildings with curved roofs as compared with flat roofs
    Tang, RS
    Meir, IA
    Etzion, Y
    [J]. SOLAR ENERGY, 2003, 74 (04) : 273 - 286
  • [3] Thermal analysis of vaulted roofs
    Hadavand, M.
    Yaghoubi, M.
    Emdad, H.
    [J]. ENERGY AND BUILDINGS, 2008, 40 (03) : 265 - 275
  • [4] An analysis of absorbed radiation by domed and vaulted roofs as compared with flat roofs
    Runsheng, T
    Meir, IA
    Etzion, Y
    [J]. ENERGY AND BUILDINGS, 2003, 35 (06) : 539 - 548
  • [5] Envelope wall/roof thermal performance parameters for non air-conditioned buildings
    Barrios, G.
    Huelsz, G.
    Rojas, J.
    Ochoa, J. M.
    Marincic, I.
    [J]. ENERGY AND BUILDINGS, 2012, 50 : 120 - 127
  • [6] Comparison of thermal performance between green roofs and conventional roofs
    Polo-Labarrios, Marco A
    Quezada-Garciá, Sergio
    Sánchez-Mora, Heriberto
    Escobedo-Izquierdo, M. Azucena
    Espinosa-Paredes, Gilberto
    [J]. Case Studies in Thermal Engineering, 2020, 21
  • [7] Comparison of thermal performance between green roofs and conventional roofs
    Polo-Labarrios, Marco A.
    Quezada-Garcia, Sergio
    Sanchez-Mora, Heriberto
    Escobedo-Izquierdo, M. Azucena
    Espinosa-Paredes, Gilberto
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2020, 21
  • [8] Wall/roof thermal performance differences between air-conditioned and non air-conditioned rooms
    Barrios, G.
    Huelsz, G.
    Rechtman, R.
    Rojas, J.
    [J]. ENERGY AND BUILDINGS, 2011, 43 (01) : 219 - 223
  • [9] Wind loads on buildings with vaulted roofs and side walls - A review
    Natalini, Bruno
    Natalini, Mario B.
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2017, 161 : 9 - 16
  • [10] Optimum thermal design of air-conditioned residential buildings
    AlHomoud, MS
    [J]. BUILDING AND ENVIRONMENT, 1997, 32 (03) : 203 - 210