Wind loads on buildings with vaulted roofs and side walls - A review

被引:8
|
作者
Natalini, Bruno [1 ,2 ]
Natalini, Mario B.
机构
[1] Univ Nacl Nordeste, Fac Ingn, Ave Las Heras 727, RA-3500 Resistencia, Argentina
[2] Consejo Nacl Invest Cient & Tecn, Buenos Aires, DF, Argentina
关键词
Wind loads; Curved roofs; Enclosed buildings; Codification; PLASTIC GREENHOUSES; CURVED ROOFS; PRESSURES;
D O I
10.1016/j.jweia.2016.12.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The recommendations of the Argentinean code of practice CIRSOC 102 concerning wind loads on enclosed buildings with curved roofs are identical to those of ASCE 7, which are based on results published in 1914. Significant differences can thus be expected if this treatment is compared with an updated bibliography. This paper reviews the information available in the open literature, including a number of significant studies written in Portuguese that are not readily accessible, with the CIRSOC 102 treatment then compared with state-of-the-art results. The need to update the code is shown, possible criteria and values are suggested, and research needs are listed.
引用
收藏
页码:9 / 16
页数:8
相关论文
共 50 条
  • [1] WIND LOADS ON BUILDINGS WITH SAWTOOTH ROOFS
    SAATHOFF, PJ
    STATHOPOULOS, T
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1992, 118 (02): : 429 - 446
  • [2] WIND LOADS ON BUILDINGS WITH SAWTOOTH ROOFS - DISCUSSION
    SRINIVASAN, CN
    ARVIND, CR
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1993, 119 (03): : 994 - 996
  • [3] Mean loads on vaulted canopy roofs
    Natalini, M. B.
    Morel, C.
    Natalini, B.
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2013, 119 : 102 - 113
  • [4] WIND LOADS ON BUILDINGS WITH SAWTOOTH ROOFS - CLOSURE
    SAATHOFF, PJ
    STATHOPOULOS, T
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1993, 119 (03): : 996 - 996
  • [5] WIND LOADS ON LOW BUILDINGS WITH MONO-SLOPED ROOFS
    STATHOPOULOS, T
    MOHAMMADIAN, AR
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1986, 23 (1-3) : 81 - 97
  • [6] A review of wind loads on canopies attached to walls of low-rise buildings
    Sakib, Faruk Ahmed
    Stathopoulos, Ted
    Bhowmick, Anjan K.
    [J]. ENGINEERING STRUCTURES, 2021, 230
  • [7] RANS Simulation of Wind Loading on Vaulted Canopy Roofs
    Amaya-Gallardo, Edmundo
    Pozos-Estrada, Adrian
    Gomez, Roberto
    [J]. KSCE JOURNAL OF CIVIL ENGINEERING, 2021, 25 (12) : 4814 - 4833
  • [8] RANS Simulation of Wind Loading on Vaulted Canopy Roofs
    Edmundo Amaya-Gallardo
    Adrián Pozos-Estrada
    Roberto Gómez
    [J]. KSCE Journal of Civil Engineering, 2021, 25 : 4814 - 4833
  • [9] Thermal performance of non air-conditioned buildings with vaulted roofs in comparison with flat roofs
    Tang, RS
    Meir, IA
    Wu, T
    [J]. BUILDING AND ENVIRONMENT, 2006, 41 (03) : 268 - 276
  • [10] Wind loads on low-slope roofs of buildings with large plan dimensions
    Aldoum, Murad
    Stathopoulos, Ted
    [J]. ENGINEERING STRUCTURES, 2020, 225