Thermal performance of non air-conditioned buildings with vaulted roofs in comparison with flat roofs

被引:35
|
作者
Tang, RS [1 ]
Meir, IA
Wu, T
机构
[1] Yunnan Normal Univ, Solar Energy Res Inst, Kunming 650092, Peoples R China
[2] Ben Gurion Univ Negev, Jacob Blaustein Inst Desert Res, Desert Architecture & Urban Planning Unit, IL-84990 Sede Boqer, Israel
关键词
vaulted roof; thermal performance; non air-conditioned buildings;
D O I
10.1016/j.buildenv.2005.01.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Vaulted or domed roofs have been frequently adopted by builders and architects throughout the Middle East and other hot dry areas. However, the thermal performance of such buildings under hot dry climatic conditions has rarely been quantitatively studied. In this paper, a detailed finite element model for the investigation of the thermal performance of non air-conditioned buildings with vaulted roofs (VR) is suggested based on two-dimensional unsteady heat transfer in such roofs and solar geometry. This model allows a comparison of the thermal performance of non air-conditioned buildings with a VR and a flat roof (FR) under different climatic conditions. Results obtained by numerical calculation show that, irrespective of building type the VRs are applied to, buildings with a VR have lower indoor temperatures as compared to those with a FR. The reason is that such roofs dissipate more heat than a FR does by convection and thermal radiation at night due to the enlarged curved surfaces. This implies that such roof forms are suitable for buildings located in hot dry regions but not for those located in hot humid areas, and reasonably explains why curved roofs have been extensively adopted by builders and architects in the hot dry areas in the past. However, with the decrease in the half rim angle of a VR, the difference of indoor thermal condition between a VR and a FR building becomes small and insignificant. Results also indicate that the indoor air temperature is slightly influenced by the half rim angle theta(0) and the orientation phi(v) of the VR. To be effective to create a favorable thermal condition inside buildings with a VR under hot dry climatic conditions, the half rim angle of a VR should be theta(0) > 50 degrees, instead of theta(0) < 50 degrees, which is the optimal half rim angle of a VR of air-conditioned buildings, as found by the present authors in a previous study. (C) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:268 / 276
页数:9
相关论文
共 50 条
  • [21] SIMILITUDE AND THERMAL PERFORMANCE ON NON-CONVENTIONAL ROOFS
    Sampaio, Carlos A. de P.
    Terezo, Rodrigo F.
    Rosa, Talitha O.
    Burigo, Mariana C.
    Andrade, Leonardo de B.
    [J]. ENGENHARIA AGRICOLA, 2018, 38 (01): : 7 - 12
  • [22] Green Roofs in Buildings: Thermal and Environmental Behaviour
    Theodosiou, Theodore
    [J]. ADVANCES IN BUILDING ENERGY RESEARCH, 2009, 3 (01) : 271 - 288
  • [23] Thermal comfort in rural buildings with green roofs
    Costa Junior, C. R.
    Cordeiro-Junior, J. J. F.
    Omar, A. J. S.
    Guiselini, C.
    Loges, V.
    Silva-Junior, G. R.
    Pandorfi, H.
    [J]. INTERNATIONAL SYMPOSIUM ON GREENER CITIES FOR MORE EFFICIENT ECOSYSTEM SERVICES IN A CLIMATE CHANGING WORLD, 2018, 1215 : 291 - 294
  • [24] Thermal performance of domed roof in air-conditioned spaces
    Reda, Ibrahim
    AbdelMessih, Raouf N.
    Steit, Mohamed
    Mina, Ehab M.
    [J]. Energy and Built Environment, 2024, 5 (02): : 270 - 287
  • [25] Indoor air quality and energy performance of air-conditioned office buildings in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, KW
    [J]. INDOOR AIR, 2003, 13 (04) : 315 - 331
  • [26] Quantification of thermal adaptation in air-conditioned buildings of composite climate, India
    Dhaka, Shivraj
    Mathur, Jyotirmay
    [J]. BUILDING AND ENVIRONMENT, 2017, 112 : 296 - 307
  • [27] Thermal Adaptive Behavior of Occupants in Air-conditioned Office Buildings in Thailand
    Sikram, Tanadej
    Ichinose, Masayuki
    Sasaki, Rumiko
    [J]. SUSTAINABLE BUILT ENVIRONMENT CONFERENCE 2019 TOKYO (SBE19TOKYO) - BUILT ENVIRONMENT IN AN ERA OF CLIMATE CHANGE: HOW CAN CITIES AND BUILDINGS ADAPT?, 2019, 294
  • [28] Thermal performance of air-conditioned office buildings constructed with inclined walls in different climates in China
    Chan, A. L. S.
    Chow, T. T.
    [J]. APPLIED ENERGY, 2014, 114 : 45 - 57
  • [29] Energy savings in buildings or UHI mitigation? Comparison between green roofs and cool roofs
    Costanzo, V.
    Evola, G.
    Marletta, L.
    [J]. ENERGY AND BUILDINGS, 2016, 114 : 247 - 255
  • [30] LCA comparison of roofing materials for flat roofs
    Contarini, Antonio
    Meijer, Arjen
    [J]. SMART AND SUSTAINABLE BUILT ENVIRONMENT, 2015, 4 (01) : 97 - 109