Automated antinuclear immunofluorescence antibody analysis is a reliable approach in routine clinical laboratories

被引:11
|
作者
Zheng, Bing [1 ]
Li, Enling [1 ]
Zhu, Haoming [1 ]
Lu, Jingbo [1 ]
Shi, Xinming [1 ]
Zhang, Jie [1 ]
Li, Min [1 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Lab Med, Renji Hosp, Sch Med, 160 Pujian Rd, Shanghai 200127, Peoples R China
基金
中国国家自然科学基金;
关键词
antinuclear antibodies (ANAs); automation; indirect immunofluorescence; value-added ANA report; AUTOANTIBODIES; GUIDELINES; DIAGNOSIS; TESTS;
D O I
10.1515/cclm-2017-0050
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Indirect immunofluorescence (IIF) assays are recommended as the gold standard method for the detection of antinuclear antibodies (ANAs). This study aimed to investigate the reliability of an automated system. Methods: We compared 3745 serum samples using NOVA View archived images with manual analysis via microscopy. A custom cutoff value was established to distinguish ANA titers and was validated in two clinical laboratories. The automatic ANA pattern recognition system was evaluated, and all ANA-positive sera were subjected to two commercial ANA IIF kits to compare the consistency of the pattern interpretation results. For inconsistent patterns, a third ANA IIF testing kit was utilized. Results: Agreement of the interpretation of the ANA IIF test using the platform of NOVA View and manual microscopy was 96.9%. The local cutoff value to discriminate ANA titers in four main ANA patterns was calculated based on 1390 serum samples. In our laboratory, the titer prediction accuracy was superior to the preset cutoff in NOVA View (p < 0.01); the performance was similar in another laboratory (p = 0.11). The automatic pattern recognition accuracies of speckled, homogeneous, centromere, nucleolar and nuclear dot patterns were 62.7%, 57.4%, 92.6%, 30.5% and 27.3%, respectively. The consistency of the pattern interpretation results between INOVA and MBL kits was 95.3%. Conclusions: It is necessary to establish a custom value-added ANA report. However, confirmation of the digital immunofluorescence images by expert technicians was essential, and suspect results of an ANA pattern should be reconfirmed by another commercial ANA IIF kit to achieve more reliable results.
引用
收藏
页码:1922 / 1930
页数:9
相关论文
共 50 条
  • [41] NEW, PRACTICAL APPROACH TO DETECTING ANTIBODY TO PERTUSSIS TOXIN FOR PUBLIC-HEALTH AND CLINICAL LABORATORIES
    WONG, KH
    SKELTON, SK
    JOURNAL OF CLINICAL MICROBIOLOGY, 1988, 26 (07) : 1316 - 1320
  • [42] Evaluation of a semi-automated approach for FDG PET image analysis for routine clinical application in patients with multiple myeloma
    Wellman, Tyler J.
    Mudd, Sarah R.
    Godby, Kelly N.
    Wooten, Dustin W.
    Ross, Jeremy A.
    Bueno, Orlando F.
    Wanik, Danielle
    Divgi, Chaitanya R.
    Comley, Robert A.
    Costa, Luciano J.
    Hesterman, Jacob Y.
    TRANSLATIONAL ONCOLOGY, 2023, 37
  • [43] Clinical Performance of Two Automated Immunoassays, EliA CTD Screen and QUANTA Flash CTD Screen Plus, for Antinuclear Antibody Screening
    Yoon, Sumi
    Moon, Hee-Won
    Kim, Hanah
    Hur, Mina
    Yun, Yeo-Min
    ANNALS OF LABORATORY MEDICINE, 2022, 42 (01) : 63 - 70
  • [44] Performance analysis of automated evaluation of Crithidia luciliae-based indirect immunofluorescence tests in a routine setting - strengths and weaknesses
    Hormann, Wymke
    Hahn, Melanie
    Gerlach, Stefan
    Hochstrate, Nicola
    Affeldt, Kai
    Giesen, Joyce
    Fechner, Kai
    Damoiseaux, Jan G. M. C.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (01) : 86 - 93
  • [45] Four clinical and biological phenotypes in antiphospholipid syndrome: a cluster analysis of 174 patients with antinuclear antibody tests
    Ottavi, Marie
    Toulon, Pierre
    Casolla, Barbara
    Martis, Nihal
    FRONTIERS IN IMMUNOLOGY, 2024, 15
  • [46] Nomograms for Automated Body Composition Analysis: A Crucial Step for Routine Clinical Implementation
    Summers, Ronald M.
    RADIOLOGY, 2021, 298 (02) : 330 - 331
  • [47] Routine application of fish analysis to CVS specimens allows reliable and fast clinical managment decisions
    Rebarber, Andrei
    Evans, Mark
    Andriole, Stephanie
    Saltzman, Daniel
    Greenbaum, Rachel
    Cleary-Goldman, Jane
    Pergament, Eugene
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2007, 197 (06) : S168 - S168
  • [48] Late Breaking Abstract - Prevalence and clinical significance of antinuclear antibody (ANA) in IPF: analysis from ESTAIR study
    Wung, Peter
    Raghu, Ganesh
    Crestani, Bruno
    Richeldi, Luca
    Esperet, Corinne
    Soubrane, Christina
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [49] Associations between antinuclear antibody staining patterns and clinical features of systemic lupus erythematosus: analysis of a regional Swedish register
    Frodlund, Martina
    Dahlstrom, Orjan
    Kastbom, Alf
    Skogh, Thomas
    Sjowall, Christopher
    BMJ OPEN, 2013, 3 (10):
  • [50] A User-Centric Approach to Reliable Automated Flow Cytometry Data Analysis for Biomedical Applications
    Popp, Georg
    Joeckel, Lisa
    Klaes, Michael
    Wiener, Thomas
    Hilger, Nadja
    Stumpf, Nils
    Gross, Janek
    Duenkel, Anna
    Blache, Ulrich
    Fricke, Stephan
    Franz, Paul
    CYTOMETRY PART A, 2025, 107 (02) : 111 - 125