Clinical Performance of Two Automated Immunoassays, EliA CTD Screen and QUANTA Flash CTD Screen Plus, for Antinuclear Antibody Screening

被引:3
|
作者
Yoon, Sumi [1 ]
Moon, Hee-Won [2 ]
Kim, Hanah [2 ]
Hur, Mina [2 ]
Yun, Yeo-Min [2 ]
机构
[1] Chung Ang Univ, Dept Lab Med, Coll Med, Seoul, South Korea
[2] Konkuk Univ, Dept Lab Med, Sch Med, Seoul, South Korea
关键词
EliA CTD Screen; QUANTA Flash CTD Screen Plus; Antinuclear antibody; Indirect immunofluorescence assay; Anti-extractable nuclear antigen antibody; Performance; IMMUNOFLUORESCENCE; AUTOANTIBODIES; TESTS; ANTIGENS;
D O I
10.3343/alm.2022.42.1.63
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Recently, two fully automated immunoassays for antinuclear antibody (ANA) screening were introduced: EliA CTD Screen (Thermo Fisher Scientific, Freiburg, Germany) and QUANTA Flash CTD Screen Plus (Inova Diagnostics, San Diego, USA). We evaluated their clinical performance in comparison with the indirect immunofluorescence assay (IIFA) and analyzed samples with discrepant results. Methods: In total, 406 serum samples (206 from patients undergoing routine checkups and 200 from rheumatology clinic patients) were assayed using EliA, QUANTA Flash, and IIFA. We evaluated assay concordance and agreement and confirmed the presence of anti-extractable nuclear antigen (ENA) antibodies in samples with discrepant automated immunoassay and IIFA results. Additionally, we compared the clinical performance of each assay in diagnosing ANA-associated rheumatic disease (AARD) and adjusted the cut-off values. Results: In rheumatology clinic samples, the concordance and agreement were 91.5% and strong between EliA and QUANTA Flash, 79.0% and weak between EliA and IIFA, and 80.5% and moderate between QUANTA Flash and IIFA, respectively. In automated immunoassay-positive, IIFA-negative samples (N=15), all anti-ENA antibodies detected (6/15) were anti-SjOgren's syndrome antigen A/Ro (Ro60) antibodies. The automated immunoassays and IIFA showed high accuracy for diagnosing AARD, and adjusted cut-off values improved their sensitivities (EliA with 0.56 ratio, 82.9% sensitivity; QUANTA Flash with 9.7 chemiluminescent units, 87.8% sensitivity). Conclusions: The two automated immunoassays showed reliable performance compared with IIFA and can be efficiently used with the IIFA in clinical immunology laboratories. Clinical cut-off values can be adjusted according to the workflow in each laboratory.
引用
收藏
页码:63 / 70
页数:8
相关论文
共 10 条
  • [1] Clinical performance evaluation of a novel, automated chemiluminescent immunoassay, QUANTA Flash CTD Screen Plus
    Chelsea Bentow
    Gabriella Lakos
    Rachel Rosenblum
    Cassandra Bryant
    Andrea Seaman
    Michael Mahler
    Immunologic Research, 2015, 61 : 110 - 116
  • [2] Clinical performance evaluation of a novel, automated chemiluminescent immunoassay, QUANTA Flash CTD Screen Plus
    Bentow, Chelsea
    Lakos, Gabriella
    Rosenblum, Rachel
    Bryant, Cassandra
    Seaman, Andrea
    Mahler, Michael
    IMMUNOLOGIC RESEARCH, 2015, 61 (1-2) : 110 - 116
  • [3] The clinical significance of borderline results of the Elia CTD Screen assay
    Robier, Christoph
    Amouzadeh-Ghadikolai, Omid
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (12) : 2088 - 2092
  • [4] PERFORMANCE OF ELIA ANA CTD SCREEN COMPARED TO HEP-2 AND SERAQUEST ANA SCREENING
    Ougnou, M.
    Gomez, J. Carretero
    Sanchez, D. Lamuno
    Tenor, D. Pineda
    Jimenez, L. Rodelgo
    Gomez-Serranillos, Reus M.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S215 - S215
  • [5] Indirect immunofluorescence on HEp-2 cells vs. ELIA CTD screen for the detection of antinuclear antibodies
    Korsholm, T.
    Troldborg, A.
    Nielsen, B. D.
    SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 2014, 43 : 89 - 89
  • [6] Comparison of the clinical utility of the Elia CTD Screen to indirect immunofluorescence on Hep-2 cells
    Robier, Christoph
    Amouzadeh-Ghadikolai, Omid
    Stettin, Mariana
    Reicht, Gerhard
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (08) : 1365 - 1370
  • [7] Detection of antinuclear antibodies: a comparison of indirect immunofluorescence on HEp-2 cells and fluoroenzymeimmunoassay (EliA CTD screen, Thermo Fisher)
    Troelsen, L. N.
    Jacobsen, S.
    SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 2014, 43 : 81 - 81
  • [8] RADIAS ANA SCREEN - AN AUTOMATED ELISA ASSAY FOR ANTINUCLEAR ANTIBODY SCREENING
    GNIEWEK, RA
    BREGLIO, S
    EDWARDS, R
    CLINICAL CHEMISTRY, 1995, 41 (06) : S74 - S74
  • [9] AN ANA SCREENING ASSAY (ELIA® CTD SCREEN) CONTAINING MULTIPLE ANTIGENS INCREASES THE SENSITIVITY AND SPECIFICITY OF ANA TESTING BY INDIRECT IMMUNOFLUORESCENCE
    Steiner, G.
    Perkmann, T.
    Horn, T.
    Kiener, H. P.
    ANNALS OF THE RHEUMATIC DISEASES, 2017, 76 : 1414 - 1414
  • [10] Comparison of the Clinical Utility in the Detection of Anti-Nuclear Antibodies Between the Elia CTD Screen and Indirect Immunofluorescence on Hep-2 Cells: A Review of the Literature
    Robier, Christoph
    Amouzadeh-Ghadikolai, Omid
    Stettin, Mariana
    Reicht, Gerhard
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2018, 20 (11): : 700 - 702